IF55 ROT CANopen®
WARNING
The max. length of the SSI cable must not exceed 30 m / 98.425 ft.
4.3 CANopen converter with PGs: CB version (Figure 4 and Figure 6)
Figure 6
The converter is fitted with two PG9 cable glands for BUS IN and BUS OUT
connections. The bus cables can be connected directly to the terminal
connectors in front of each cable gland. We recommend CANbus certificated
cables to be used. Core diameter should not exceed Ø 1.5 mm (0.06”).
Terminal connector
Description
-
0Vdc
power supply voltage
+
+10Vdc +30Vdc
power supply voltage
G
CAN GND
1
L
CAN Low
H
CAN High
PG
CAN Shield
2
1
CAN GND is the 0V reference of CAN signals, it is not
connected to 0Vdc supply voltage.
2
Connect the cable shield to the cable gland.
MAN IF55 ROT CB E 1.2.odt
4 - Electrical connections
27 of 88
Содержание IF55 ROT CB
Страница 87: ...This page intentionally left blank ...