EM58 PA
1 – Start teaching
This button is available only when the
Programming mode: Start / Stop
is enabled.
After having moved the axis to the start position (0 position), i.e. the point
where the travel we need to measure starts, press this button in order to bind
the first value of the selected output range to the physical position you have
moved the axis to (origin of the axis).
2 - Stop teaching
This button is available only when the
Programming mode: Start / Stop
is enabled.
After having moved the axis to the end position, i.e. the point where the travel
we need to measure stops, press this button in order to bind the last value of
the selected output range to the physical position you have moved the axis to
(end of the axis).
WARNING
•
If the start position (
) match (i.e., you do not change the axis position during
the programming process and press the buttons when the axis is in the
same exact position), then the
Encoder travel not valid: unable to
error message is displayed.
•
If the travel is over the maximum encoder limits, then the
travel not valid: counts to be displayed greater than physical
resolution between start and stop
error message is displayed.
•
After having set the start position, if you move the axis in a direction
and then reverse the movement of the axis so going back over the start
position, then the error message is displayed.
MAN EM58 PA E 1.1
Software and configuration parameters