SFA-5000 • SFA-10000 CANopen®
Encoder
Master (confirmation)
COB-ID
Cmd
Index
Sub
Data bytes
580+ID
60
11
10
01
00
00
00
00
Master
Encoder (
Reset node
)
COB-ID
Cmd
Slave ID
000
81
ID
Encoder
Master (Boot-up)
COB-ID
Cmd
700+ID
00
NOTE
Save the default values after upload using the store parameters function (see
the
object).
1014-00 COB-ID EMCY
[Unsigned32, rw]
This object defines the COB-ID used to send emergency messages (EMCY).
If the node address is set using the internal dip-switches (i.e. at least one dip-
switch for setting the node has HIGH logic level = 1), when the power is turned
on, this object is always forced to the default value. Otherwise, if the node
address is set via software (i.e. all dip-switches for setting the node have LOW
logic level = 0) it retains the set value, unless a software procedure for setting a
new address is forced at power on. For further information please refer to the
“4.7 Setting the node address: DIP B” section on page 32.
Default = 0000 0080h
1015-00 Inhibit time EMCY
[Unsigned16, rw]
Inhibit time of the emergency messages (EMCY) expressed in multiples of 100
µs. When set to 0, this function is disabled.
Default = 0000h
1018 Identity object
01 Vendor-ID
provided by CIA organization [Unsigned32, ro]
Default = 0000 012Eh
02 Product code
[Unsigned32, ro]
Default = 0000 0000h
03 Revision number
[Unsigned32, ro]
Default = 0000 0001h
MAN SFA_5000_10000_CB E 1.0.odt