LightwaveRF LW931 Скачать руководство пользователя страница 2

EC DECLARATION OF CONFORMITY

Responsible Authority:

  LightwaveRF 

PLC, 

 

 

Innovation Campus Birmingham

  Faraday 

Wharf

  Holt 

Street 

 

  Birmingham 

 

    

  B7 

4BB 

    

 

 

Tel: +44 (0)121 250 3625

  Email: 

[email protected] 

 

Model Number(s):  

JSJSLW931

Description:  

 

Magnetic Trigger 

Directives this equipment 

Complies with:   

2006/95/EC The Low Voltage Directive N/A

 

 

2004/108/EEC The Electromagnetic Compatibility Directive

 

 

1999/5/EC R&TTE Directive

 

 

93/68/EEC CE Marking Directive

Standards Applied in order to verify compliance 

Safety: BS EN 60730-1: 2011

Health: 

R&TTE: EN 301 489-1 V1.9.2: (2011-09), EN 301 489-3 V1.4.1: (2002-08)

EN 300 220-1 V2.1.1: 2006, EN 300 220-2 V2.1.2: 2007

EMC: EN 301 489-1 V1.9.2: (2011-09), EN 301 489-3 V1.4.1: (2002-08), 

EN 55022: 2010, EN 61000-3-2: 2006 +A1: 2009 +A2: 2009 Class A, 

EN 61000-3-3: 2008, EN61000-4-2: 2009, 

EN 61000-4-3: 2006 +A1: 2008 +A2: 2010, EN 61000-4-4: 2012, 

EN 61000-4-5: 2006, EN 61000-4-6: 2009, EN 61000-4-11: 2004

  

For and on behalf of LightwaveRF PLC

----------------------------------------

Name  

J Shermer  

Position 

Managing Director

Содержание LW931

Страница 1: ...Professional Series www lightwaverf house Instruction Manual Version 2 1 Magnetic Trigger Model No LW931...

Страница 2: ...1999 5 EC R TTE Directive 93 68 EEC CE Marking Directive Standards Applied in order to verify compliance Safety BS EN 60730 1 2011 Health R TTE EN 301 489 1 V1 9 2 2011 09 EN 301 489 3 V1 4 1 2002 08...

Страница 3: ...eating devices such as the Thermostatic Radiator Valve TRV Home or Room Thermostat or Electric Switch When the door or window that the trigger is attached to is opened or closed the radiator in the ro...

Страница 4: ...er LightwaveRF devices to the Magnetic Trigger For additional guidance please visit www lightwaverf com Battery compartment catch LED indicator Overview Linking button Magnet section Line up the dots...

Страница 5: ...B will cause an on command to be sent Inserting the batteries Attaching to a door or window and frame The Magnetic Trigger can be attached to a window frame using adhesive pads provided or by using s...

Страница 6: ...s opened or closed The trigger will automatically setback a TRV an Electric Switch or Thermostat default of 11 degrees if a window is opened and return them to their previous set temperature when the...

Страница 7: ...dicate a successful link Note linking mode lasts for 12 seconds if no linking command is received within this time then linking mode will time out and the process will have to be re initiated To compl...

Страница 8: ...ts house temp Magnetic Trigger open window turns off TRV TRV controls radiator Room by room radiator control Lightwave App control from anywhere Boiler OR Electric Switch turns boiler on off Home Ther...

Страница 9: ...the batteries The average battery life should be at least one year although this will vary depending on use The LED indicator will flash ten times to report a low battery status If this measure fails...

Страница 10: ...s of the Trigger can be made to match up together the device will work Q Can I link more than one TRV to a trigger A You can currently only link one TRV directly Q Is it legal for me to install a Ligh...

Страница 11: ...Specification RF frequency 868 MHz Batteries 2 x 1 5V AAA Warranty 2 year standard warranty Technical Specification...

Страница 12: ...Version 2 1 2 Quadrant Park Mundells Welwyn Garden City Herts AL7 1FS 01707 386035 www lightwaverf house...

Отзывы: