;05
7URXEOHVKRRWLQJ
6WXGLR 6SRWŒ
583 2
6WXGLR &RORU
Š
583
8VHU 0DQXDO
BOOT
DIFF ERR
The current boot code does not
match the new boot code. This
error may occur after you
upload new software.
Update the boot code (see “Copying the Boot Code
(BOOT)” on page 4-31).
COOL
The lamp is too hot to strike.
The fixture will automatically restrike the lamp when it
has sufficiently cooled.
EMEM
ACK
During data storage, an
attempted write has taken too
long and caused an EEPROM
error.
Contact High End Systems customer service (see
“Contacting High End Systems” on page ii).
EMEM
[message]
The fixture experienced a
memory failure and was unable
to retrieve one of the following
construct values:
CHNL, DSPL, FHRS, LENS,
LHRS, L/ST, MODE, TYPE, P/
IN, T/IN, SWAP, TIME.
An electrical event may have interrupted or corrupted
data for the listed construct. Try manually entering the
construct value or contact High End Systems customer
service (see “Contacting High End Systems” on page ii).
ERSE
FLSH
During a crossload, erasing the
memory has taken too long due
to a bad comm board or a bad
data bus.
Contact High End Systems customer service (see
“Contacting High End Systems” on page ii).
FMEM
ERR
Read/write error from Flash
ROM.
Contact High End Systems customer service (see
“Contacting High End Systems” on page ii).
HEAD
TEMP
ERR
• The internal temperature of
the fixture’s head is too high.
• Make sure the fixture’s fan is working by placing your
hand over the fan’s exhaust located on the back of the
fixture’s head. If you do not feel air movement, the fan
has failed. Contact High End Systems customer
service (see “Contacting High End Systems” on page
ii).
• Remove any object which may be obstructing the fan
vents on the back of the fixture’s head.
• Check and reduce ambient temperature by turning on
fans and/or moving the fixture if it is close to a heat
source.
ID LOST
or ID ERR
The fixture was unable to
retrieve the unique DMX start
channel / fixture address.
Contact High End Systems customer service (see
“Contacting High End Systems” on page ii).
LAMP
OUT
• Failed lamp.
• Lamp power supply failure.
• The fixture lost track of the
lamp status during an
electrical event.
• Replace lamp (see “Replacing the Lamp” on page
7-4).
• Allow the fixture 5 to 10 minutes to cool, then attempt
to strike the lamp (see “Turning the Lamp On or Off
(LAMP)” on page 4-30).
• Contact High End Systems customer service (see
“Contacting High End Systems” on page ii).
7DEOH
;041
/(' (UURU 0HVVDJHV
Display
Message
Problem
Solution
Содержание High End Systems Studio 250 Series
Страница 114: ...8045 3UHVHW 3URJUDPPLQJ 6WXGLR 6SRWŒ 583 2 6WXGLR RORUŠ 583 8VHU 0DQXDO ...
Страница 122: ...90 DVHU LPLQJ HYLFH Œ 2SHUDWLRQ 6WXGLR 6SRWŒ 583 2 6WXGLR RORUŠ 583 8VHU 0DQXDO ...
Страница 154: ... 045 7URXEOHVKRRWLQJ 6WXGLR 6SRWŒ 583 2 6WXGLR RORUŠ 583 8VHU 0DQXDO ...
Страница 182: ...LQGH 07 6WXGLR 6SRWŒ 583 2 6WXGLR RORUŠ 583 8VHU 0DQXDO ...
Страница 183: ... ...
Страница 184: ......