7. LW3 Programmers’ Reference
UCX series – User's Manual
124
Applied firmware package: v1.2.0b9 | LDC software: v2.5.10b1
8.12.6.
Copy an EDID to User Memory
Command and Response
ç
CALL·/V1/EDID:copy(
<source>
:
<destination>
)
æ
mO
·
/V1/EDID:copy
Parameters
Parameter
Parameter description
Values
Value description
<source>
Source EDID memory place
F1-F148
Factory EDIDs
U1-U100
User EDIDs
D1-D2
Dynamic EDIDs
<destination>
The emulated EDID memory of the desired input port
U1-U100
User EDIDs
Example
ç
CALL /V1/EDID:copy(F1:U2)
æ
mO /V1/EDID:copy
8.12.7.
Deleting an EDID from User Memory
Command and Response
ç
CALL·/V1/EDID:delete(
<user_edid>
)
æ
mO
·
/V1/EDID:delete
Parameters
Parameter
Parameter description
Values
Value description
<user_edid>
The emulated EDID memory of the desired input port.
U1-U14
User EDIDs
Example
ç
CALL /V1/EDID:delete(U2)
æ
mO /V1/EDID:delete
8.12.8.
Resetting the Emulated EDIDs
Command and Response
ç
CALL·/V1/EDID:reset()
æ
mO
·
/V1/EDID:reset
Parameters
Parameter
Parameter description
Values
Value description
<user_edid>
The emulated EDID memory of the desired input port.
U1-U14
User EDIDs
Example
ç
CALL /V1/EDID:reset()
æ
mO /V1/EDID:reset
Calling this method switches all emulated EDIDs to factory default one. See the table in the
section.