9. Programmer's Reference
UBEX series – Matrix Application Mode – User's Manual
142
9. Programmer's Reference
UBEX series – Matrix Application Mode – User's Manual
142
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
9.17.5. Adding Tags to the Port
The following characters are allowed in the
<tag>
parameter: non-capital letters (
a-z
), capital letters (
A-Z
),
numbers (
0-9
), and special characters (
- . _ ~ : / ? # [ ] @ ! $ & ( ) + = *
).
Command and Response
ç
CALL•/MEDIA/CONTROL/ETHERNET/
<port>
:addTags(
<tag>
)
æ
mO•/MEDIA/CONTROL/ETHERNET/
<port>
:addTags=
Example
ç
CALL /MEDIA/CONTROL/ETHERNET/P102:addTags(laptop;1gbps)
æ
mO /MEDIA/CONTROL/ETHERNET/P102:addTags=
9.17.6. Deleting Tags of the Port
Command and Response
ç
CALL•/MEDIA/CONTROL/ETHERNET/
<port>
:removeTags(
<tag>
)
æ
mO•/MEDIA/CONTROL/ETHERNET/
<port>
:removeTags=
Example
ç
CALL /MEDIA/CONTROL/ETHERNET/P103:removeTags(macbook;meeting_room)
æ
mO /MEDIA/CONTROL/ETHERNET/P103:removeTags=
9.17.7. Deleting All Tags of the Port
Command and Response
ç
CALL•/MEDIA/CONTROL/ETHERNET/
<port>
:removeAllTags()
æ
mO•/MEDIA/CONTROL/ETHERNET/
<port>
:removeAllTags=
Example
ç
CALL /MEDIA/CONTROL/ETHERNET/P101:removeAllTags()
æ
mO /MEDIA/CONTROL/ETHERNET/P101:removeAllTags=
9.17.8. Query All Tags of the Device
The query returns with all the tags which belongs to the device. One tag is always reserved for the MAC
address of the endpoint.
Command and Response
ç
GET•/MEDIA/CONTROL/ETHERNET/
<port>
.DeviceTags
æ
pr•/MEDIA/CONTROL/ETHERNET/
<port>
.DeviceTags=
<tag>
Example
ç
GET /MEDIA/CONTROL/ETHERNET/P101.DeviceTags
æ
pr /MEDIA/CONTROL/ETHERNET/P101.DeviceTags=Laptop;A8:D2:36:F0:00:35;TX_MeetingRoom;#2
9.18. Serial Port Configuration - MMU
INFO:
The serial port numbering can be found in the
Control Port Numbering of the MMU
section.
9.18.1. BAUD Rate Setting
Command and Response
ç
SET•/MANAGEMENT/CONTROL/SERIAL/
<port>
.Baudrate=
<baudrate>
æ
pw•/MANAGEMENT/CONTROL/SERIAL/
<port>
.Baudrate=
<baudrate>
Parameters
Identifier
Parameter description
Value
Explanation
<number>
Baud rate value
0
0
200
200
300
300
600
600
1200
1200
1800
1800
2400
2400
4800
4800
9600
9600
19200
19200
38400
38400
57600
57600
115200
115200
Example
ç
SET /MANAGEMENT/CONTROL/SERIAL/P2.Baudrate=9600
æ
pw /MANAGEMENT/CONTROL/SERIAL/P2.Baudrate=9600
#rs232 #rs-232 #serial