14. Appendix
UBEX series – Matrix Application Mode – User's Manual
187
14. Appendix
UBEX series – Matrix Application Mode – User's Manual
187
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
Parameter
Setting/Value
RS-232 port settings
Operation mode
Command injection
TCP port
8001
Baud rate
57600
Data bits
8
Parity
None
Stop bits
1
Miscellaneous
Application mode
Auto
Unique port names
Cleared
Unique device label
Cleared
User EDIDs
Not cleared
14.2.3. UBEX-MMU-X200
Parameter
Setting/Value
Network settings
IP address
192.168.0.100
Subnet mask
255.255.255.0
Static gateway
192.168.0.1
DHCP
Disabled
LW3 port number
6107
RS-232 port configuration
Configuration
BAUD 115200 8N1
UBEX matrix
UBEX matrix database, including:
▪
Database of claimed endpoints;
▪
Crosspoint settings;
▪
Stream names;
▪
Device names;
▪
Tags;
▪
Port properties;
▪
Scaler / FRC / CSC settings;
▪
Video wall configuration.
Cleared
14.3. Content of Backup File
The backup file contains numerous settings and parameters saved
from the device. When the file is uploaded to a device, the followings
will be overwritten.
INFO:
The configuration settings of the endpoint devices are stored
in the MMU in Matrix applicatio mode.
For the procedure of the backup and restore function see the details
section.
UBEX-MMU-X200
General
Device label
NTP mode, NTP server address
Endpoint management settings
List of the claimed endpoints
Operation mode of the endpoints
Device assignments
Crosspoint settings
Video stream connection states, Audio stream connection states
Stream source settings
Stream names, Tags, Icons
HDCP setting
Scaler enable/disable status, Resolution setting, Image position
Frame rate converter enable/disable status, Resolution setting
Color space conversion setting
Destination port settings
Stream names, Tags, Icons
HDCP mode, Power +5V mode, Color depth setting
Scaler enable/disable status, Resolution setting, Image position
Frame rate converter enable/disable status, Resolution setting
Color space conversion setting
No sync screen mode, No sync screen color
Video wall settings
All video wall related settings
EDID management settings
User EDID data, Emulated EDIDs by ports, Dynamic EDID data
Ethernet port settings
MMU control ports: Name, Mode
Endpoint control ports: Name, Mode
Serial port configuration
MMU: Baudrate, Databits, Stopbits, Parity
Endpoints: Baudrate, Stopbits, Parity, Port name
14.4. Control Port Numbering of the MMU