8. The alarm interface

The alarm output is a 0 V to 3.3 V signal that becomes active low when the distance reading falls below a preset distance. The 
distance value used to calculate the alarm state is taken from the analog port settings. However, the maximum range selection of 
the analog port does not limit the operational range of the alarm. 

Figure 9 :: Alarm interface connections

The “7: Alarm activation distance” setting determines the distance below which the alarm signal becomes active (low). There is 
hysteresis on this set point equal to the resolution of the reading or 0.06 m, whichever is the larger. 

The “8: Alarm latch” selection turns on or off a latching function that keeps the alarm in an active state until a reset command is 
received. The reset can be from the serial port (#X:) or from the keyboard if the USB cable is connected by pressing the 

<X>

 key. 

9. USB port settings 

The “9: USB port update rate” setting allows the user to adjust the update rate of the distance readings to make them more 
readable in the Terminal window. 

Setting

Values

Description

7: Alarm activation distance

0.5 m ... 120 m

Sets the distance below which the alarm signal will change to a low state. There 
is hysteresis on this setting equal to the “2: Snapshot resolution” setting or   
0.06 m whichever is the greater value.

8: Alarm latch

Off <-> Active

Enables the alarm signal latch. This keeps the alarm in the active low state after 
an alarm event until it is cleared by sending the “#X:” command to the serial 
port or by pressing 

<X> 

on the keyboard.

Setting

Values

Description

9: USB port update rate

10 ... 190 / sec

Sets the rate at which new results are output from the USB port when it is selected 
using “1. Active data port”. 

The maximum value is limited to 190 readings per second. 

Only whole number fractions of 3052 will give an exact match between the entered 
and actual values.

SF33 Multi-beam sensor - Product Manual - Revision 1 

 of 

© LightWare Optoelectronics (Pty) Ltd, 2016

12

15

Содержание SF33

Страница 1: ...Configurable features and multiple hardware interfaces make connection with different types of controllers easy The SF33 uses a time of flight system to make very fast and accurate distance measureme...

Страница 2: ...re 12 Dimension drawings of the SF33 10 Disclaimer Information found in this document is used entirely at the reader s own risk and whilst every effort has been made to ensure its validity neither Lig...

Страница 3: ...ta Analog port An analog voltage proportional to the shortest distance reading Alarm A logic level signal that warns when the distance measured is below a preset value USB port Connects to a Terminal...

Страница 4: ...inal software and click the Connect icon to open a communications port 5 If the connection isn t made automatically click the Laser icon and select the correct USB port from the list shown 6 Press the...

Страница 5: ...10 3052 sec Sets the rate at which the analog port and the alarm signal are updated with distance readings The actual value may be lower than the entered value depending on the setting 2 Snapshot reso...

Страница 6: ...be powered directly from the USB port of a PC or laptop This is particularly useful for testing the SF33 before it is installed in your system and also for changing the settings in readiness for the...

Страница 7: ...USB cable it is convenient to have the distance results displaying in the Terminal window Select the USB option with the SF33 running and the distances from each laser beam along with the output volt...

Страница 8: ...he baud rate is set too low there won t be enough time for the data to complete a transmission before the next result is ready The Serial port update rate is reduced if this situation occurs Both the...

Страница 9: ...e changed on the fly and a serial port command set is provided for this purpose These commands will allow changes to a subset of the settings available through the USB port Serial port commands are se...

Страница 10: ...r 10 95 Vnnnnn 1 00 m 10 3052 Sets the rate at which the analog port and the alarm signal are updated with distance readings The actual value may be lower than the entered value depending on the setti...

Страница 11: ...Analog maximum range selection changes the value in meters that equates to 2 56 V This can be either 128 m 64 m 32 m 16 m or 8m depending upon the requirements of the application Setting Values Descr...

Страница 12: ...s connected by pressing the X key 9 USB port settings The 9 USB port update rate setting allows the user to adjust the update rate of the distance readings to make them more readable in the Terminal w...

Страница 13: ...3 There are no user serviceable parts and maintenance or repair must only be carried out by the manufacturer or a qualified service agent No regular maintenance is required for the SF33 but if the len...

Страница 14: ...20 C Power supply voltage 5 0 V 0 5 V DC 5 0 V 0 5 V DC Power supply current 250 mA maximum 250 mA maximum Outputs interfaces Serial analog Serial analog Dimensions 30 x 56 5 x 50 millimeters 30 x 56...

Страница 15: ...le type 1 35 cm Revision history Version Date Authors Comments Rev 1 2016 02 23 TLP Updated Appendix A Specifications to include FDA accession number 1610094 000 2016 02 page 14 Rev 0 2015 09 23 JEP F...

Отзывы: