7. LW3 Programmers’ Reference
RAP-B511 series
– User's Manual
47
7.3.
System Commands
7.3.1. Query the Product Name
The name of the product is a read-only parameter and cannot be
modified.
Command and Response
Ý
GET·/.ProductName
Ü
pr·/.ProductName=
<product_name>
Example
Ý
GET /.ProductName
Ü
pr /.ProductName=RAP-B511-EU-K
7.3.2.
Set the Device Label
ATTENTION!
The device label can be changed to a custom text in
the
tab of the LDC software. This writable parameter is not
the same as the ProductName parameter.
Command and Response
Ý
SET·/MANAGEMENT/ LABEL.DeviceLabel=
<custom_name>
Ü
pw·/MANAGEMENT/LABEL.DeviceLabel=
<custom_name>
The Device Label can be 31 character length and ASCII characters are
allowed. Longer names are truncated.
Example
Ý
SET /MANAGEMENT/LABEL.DeviceLabel=RAP-B511
Ü
pw /MANAGEMENT/LABEL.DeviceLabel=RAP-B511
7.3.3. Query the Serial Number
Command and Response
Ý
GET·/.SerialNumber
Ü
pr·/.SerialNumber=
<serial_nr>
Example
Ý
GET /.SerialNumber
Ü
pr /.SerialNumber=00009865
7.3.4. Query the Firmware Version
Command and Response
Ý
GET·/SYS/MB.FirmwareVersion
Ü
pr
·
/SYS/MB.FirmwareVersion=
<firmware_version>
Example
Ý
GET /SYS/MB.FirmwareVersion
Ü
pr /SYS/MB.FirmwareVersion= v1.0.1b2
7.3.5.
Resetting the Device
The device can be restarted – the current connections (LAN, RS-232
or USB) will be terminated.
Command and Response
Ý
CALL·/SYS:reset()
Ü
mO
·
/SYS:reset=
Example
Ý
CALL /SYS:reset()
Ü
mO /SYS:reset=
7.3.6. Restore the Factory Default Settings
Command and Response
Ý
CALL·/SYS:factoryDefaults()
Ü
mO
·
/SYS:factoryDefaults=
Example
Ý
CALL /SYS:factoryDefaults()
Ü
mO /SYS:factoryDefaults=
The device is restarted, current connections are terminated, and the
default settings are restored. See the complete list in the
section.
7.3.7.
Enable PoE
Command and Response
Ý
SET·/SYS/MB/POE.PoeEnabled=
<PoE_status>
Ü
pw·/SYS/MB/POE.PoeEnabled=
<PoE_status>
Parameters
<PoE_status>
True
: PoE sending is enabled on P2 Ethernet port.
False
: PoE sending is disabled on P2 Ethernet port.
Example
Ý
SET /SYS/MB/POE.PoeEnabled=true
Ü
pw /SYS/MB/POE.PoeEnabled=true
INFO: The RAP-B511 sends PoE when the connected device is also
PoE-compatible.