MX16x16DVI-Slim
User’s Manual Rev. 1.0
Section 5. Web control
– Using built-in website
Page 43 / 78
Load Preset
Step 1.
Select the preset memory location (Preset1...Preset32) you want to load as
next configuration.
Step 2.
Press the Load Preset button. Now the preset is loaded
Step 3.
The new I/O configuration is displayed on the matrix switching area.
5.3.3. Output settings
Control
menu
Output settings
page
contains advanced settings for output
parameters. Some settings are only accessible with Lightware PRO series routers.
Scope of changes
The affected output can be selected in the top box, or changes can be applied to
all outputs. To set the scope of the changed settings, select the desired option in
the top left box.
Apply changes to current output:
this option means the modified parameters
are applied only to the currently selected port.
Apply changes to all outputs:
this option means that the modified parameters are
applied to all output ports.
Info:
When opening this window again, the scope selection will
be set to “Current
Output” regardless of the active selection at the time of closing. It is to avoid
making changes to all outputs by mistake.
Reload factory defaults
Current output:
Reloads the default values to the currently selected output.
All outputs:
Loads the factory default values to all outputs.
Drive current
It specifies the drive current of the internal crosspoint circuit. It is strongly
recommended to leave this value at the default 12 mA setting.
This setting does not affect the output directly, only an internal signal. Modifications
are done promptly when selecting a value from the drop down list.
Warning
Drive currents over 24 mA should be used with extreme caution since this could
damage TMDS transceivers in DVI devices!
!