76
Set number of lost signal
conditions
RW
4
4
Y
79
Serial baud rate
RW
1
1
Y
80
I2C address
RW
1
1
Y
82
Enable/disable the
median filter
RW
1
1
Y
83
Set the median filter size
RW
4
4
Y
84
Enable/disable the
median filter
RW
1
1
Y
85
Set the smoothing
intensity/factor
RW
4
4
Y
93
Enables rolling average
RW
1
1
Y
94
Size of rolling average
RW
4
4
Y
Command descriptions
0. Product name
A 16 byte string indicating the product model name. This will always be LW24/C followed by a null terminator. You can
use this to verify the LW24/C is connected and operational over the selected interface.
Read
Write
Persists
16 byte string
-
-
1. Hardware version
The hardware revision number as a uint32.
Read
Write
Persists
uint32
-
-
2. Firmware version
The version of currently installed firmware is represented as 4 bytes. This can be used to identify the product for API
compatibility. The
section details which firmware versions this document applies to.
1
2
3
4
Patch
Minor
Major
Reserved
Read
Write
Persists
4 bytes
-
-
LW24/C/SI microLiDAR™ sensor - Product guide
|
Version 0
|
03 March 2022
Page
27
of
36