7
194
8
388
Read
Write
Persists
uint8
uint8
Yes
74. Noise
Reading this command will return the level of background noise.
Read
Write
Persists
uint32
-
-
75. Zero offset
Changing this offset value will change the Zero distance position for the output. This value is written and read in mm.
Read
Write
Persists
int32
int32
Yes
76. Lost signal counter
The lost signal counter is used to determine the number of lost signal returns that needs to be generated before a lost
signal indication is output on the distance value. The lost signal indication on the distance output value is -1000.
Read
Write
Persists
int32
int32
Yes
79. Baud rate
The baud rate as used by the serial interface. This parameter only takes effect when the serial interface is first enabled
after power-up or restart.
Reading this command will return the baud rate. Writing to this command will set the baud rate.
Value
Baud rate [bps]
0
9600
1
19200
2
38400
3
57600
4
115200
5
230400
6
460800
7
921600
LW24/C/SI microLiDAR™ sensor - Product guide
|
Version 0
|
03 March 2022
Page
33
of
36