Symptom

Problem Isolation Steps

Resolution

Feedback

Check

that the volume on the RC2 is not 
set too high.

Reduce volume as needed until feedback issue is 
resolved. Remember the teacher should barely be 
able to hear his/her own voice at optimum volume 
levels.

Check

that the microphone is being 
worn properly.

The top of the microphone should be worn at the 
level of the collarbone. Adjust lanyard accordingly.

Check

that the tone is set to the mid-
point.

Set the tone indicator to the 9 o’clock position 
and then adjust as needed to eliminate feedback.

Test

the original microphone with 
another system that is working 
properly.

If the problem persists with the other system, the 
microphone is likely the cause of the problem.

Low volume

Check

that the volume level on the RC2 
is not set too low.

Position the volume indicator at the 12 o’clock 
position and then adjust as needed for normal 
operation.

Check

that the microphone is being 
worn properly.

The top of the microphone should be worn at the 
level of the collarbone.

Check

a known good microphone on 
the same channel with the RC2.

If the volume level remains the same as the 
original microphone, the most likely cause of the 
problem is the RC2.

Drop-out / 
intermittent 
operation

Check

if two microphones are being 
used that they are on different 
channels.

If needed, change one microphone to the oppo-
site channel.

Check

that there is no obstruction be-
tween the RC2 and the micro-
phone.

Make sure the microphone is not blocked by 
clothing or turned to face the user.

Check

RC2 placement in the room.

Evaluate the RC2 location in the room and adjust 
as needed.  It should be located near the center of 
the room along a long wall. Avoid placing it near 
obstructions.

Check

that the RC2 is located away from 
possible sources of IR interfer-
ence.

Direct sunlight and Plasma monitors can adversely 
affect performance.

Check

that a known good microphone 
works with the system being 
tested.

If the intermittent operation stops, the original 
microphone is likely the cause of the problem. If 
the problem continues, the RC2 is the most likely 
cause.

REDMIKE2 
(RMT2) will not 
power on

Check

that the correct battery is being 
used.

Use the Lightspeed NH2A27 NiMH rechargeable 
sensing battery as it is the only kind of battery that 
will properly charge with the RMT2.

Check

that the battery is installed prop-
erly.

Ensure that the polarity is observed.