8 5 0 i R U s e r M a n u a l
850iR User Manual | 10
3. IR SENSOR INSTALLATION
Sensor location is very important for optimum performance of the 850iR Classroom Audio
System.
• BEST:
On the ceiling at or near the middle of the classroom.
• GOOD:
High and centered on the long wall.
• AVOID:
Locations in corners, on walls at heights lower than 7 feet, or in places
where the line of sight is or could be obstructed.
Before
adjusting the graphic equalizer refer to the intial set-up on page 18. Sometimes fine-tuning
is required to eliminate feedback.
Fine-tuning the Graphic Equalizer:
1. Slide
up and flip down the EQ cover door.
2. Walk
the room listening for feedback (squealing).
3. Lower
the 2K5 and/or 4K sliders if a high-pitched ring is present.
4. Lower
the 400 and/or 700 sliders if a low-pitched ring is present.
5. Reduce
volume if feedback is still present.
Helpful Hint
Good placement
Best placement
Avoid!
Содержание 850iR
Страница 1: ...U s e r M a n u a l 850iR Classroom Audio System...
Страница 2: ......
Страница 6: ...8 5 0 i R U s e r M a n u a l 1 850iR User Manual SECTION 1 System Overview...
Страница 12: ...8 5 0 i R U s e r M a n u a l 7 850iR User Manual SECTION 2 Installation...
Страница 22: ...8 5 0 i R U s e r M a n u a l 17 850iR User Manual SECTION 3 Initial Set up Charging and Additional Features...
Страница 27: ...8 5 0 i R U s e r M a n u a l 850iR User Manual 22 SECTION 4 Optional Microphones and Accessories...
Страница 39: ...8 5 0 i R U s e r M a n u a l 850iR User Manual 34 SECTION 5 Troubleshooting Daily Use and Warranty...
Страница 46: ...8 5 0 i R U s e r M a n u a l 41 850iR User Manual USER NOTES...
Страница 47: ......