TL - 4008 MEMORY CONTROL CONSOLE 

 Revision  1.4   

 

 

 

 

 

 

 

 

 

OWNERS MANUAL   

 

 

 

 

 

 

 

 

02/17/2005 

www.lightronics.com 

Lightronics 

Inc. 

        509 

Central 

Drive 

 

Virginia 

Beach, 

 

VA 

 

23454 

        

 

 

757 

486 

3588 

 

SPECIFICATIONS 

 
 
 
 
 
 
 
 
 
 

Number of channels  16 or 8 depending on mode 
Operating modes   

8 channels x 2 manual scenes 

       16 

channels 

manual 

scene 

       8 

channels 

and 

recorded 

scenes 

Scene memory   

 

8 scenes total 

Chase     2 

programmable 

40 

step 

chases 

Control 

protocol 

  LMX-128 

(multiplex) 

       USITT 

DMX-512 

is 

optional 

Output connector   

3 pin female XLR connector 

       5 

pin 

female 

XLR 

for 

DMX-512 

Compatibility 

   Multiplex 

protocol 

compatible 

 

 

 

 

 

 

 

with other multiplex systems 

Power 

input 

   13VAC 

or 

+15VDC 

       Optional 

external 

power 

supply 

Dimensions   

 

 

10.25"W X 9.25"D X 2.5"H 

Weight     4.4 

Pounds 

Other features of the TL-4008 include: grand master fader,  split dipless crossfader, momentary "bump" buttons, 
and blackout control. Two 40 step chases may be run simultaneously for complex patterns. Chase rate is set by 
tapping the rate button at the desired rate.  Scenes and chases stored in the unit are not lost when the unit is 
turned off. 
 

INSTALLATION 

 
The TL-4008 control console should be kept away from moisture and direct sources of heat. 
 
LMX CONNECTIONS:  Connect the unit to a Lightronics (or compatible) dimmer using a multiplex control cable 
with 3 pin XLR connectors.  The TL-4008 is powered by the dimmer which it is connected to.  It may also be 
powered via an optional external power supply.  The unit will operate with dimmers in both the NSI/SUNN and 
Lightronics modes.  All dimmers connected to the unit MUST be in the SAME mode. 
 
DMX CONNECTIONS:  Connect the unit to a DMX dimmer using a control cable with 5 pin XLR connectors.  The 
DMX-512 connection does NOT provide console power therefore an external power supply (provided with units 
having DMX option) must be used.   

DMX-512 Connector Wiring 

(5 PIN FEMALE XLR) 

 

LMX-128 Connector Wiring 

(3 PIN FEMALE XLR) 

 
 

PIN # 

SIGNAL NAME 

1 Common 

DMX data -  

DMX data + 

4 Not 

Used 

5 Not 

Used 

 

PIN # 

SIGNAL NAME 

1 Common 

Phantom power from dimmers 

No15VDC  

LMX-128 multiplex signal 

 
 
 
 
 
 
 

CONTROLS AND INDICATORS 

 
X Faders: 

 

 

 

Controls individual channel levels for channels 1 – 8. 

Y Faders: 

 

 

 

Controls level of scenes or individual channels depending on current operating mode. 

Cross Faders:   

 

Fades between X and Y row faders. 

Bump Buttons:   

 

Activates associated channels at full intensity while pressed. 

Chase Select:   

 

Turns chases on and off. 

Chase Rate:  

 

 

Press three or more times at desired rate to set chase speed. 

Y Mode Indicators:  

Indicate current operating mode of Y faders. 

Y Mode Button:  

 

Selects operating mode of Y faders. 

Blackout Button: 

 

Turns on and off console output from all scenes, channels, and chases. 

Blackout Indicator:   

Lighted when blackout is active. 

Grand Master:   

 

Adjusts output level of all console functions. 

Record Button:   

 

Records scenes and chase patterns. 

Record Indicator:   

Flashes when chase or scene recording is active. 

 