CHANNEL CONFIGURATIONS
The TL-2448 can be set to control when and how each fixture function is applied to a scene. There are 4
conditions which can be applied:
LAMP FADE - Causes that function to proceed to its new value at the scene fade rate. Additionally, the position
of the GRAND MASTER fader is applied to the scene and the condition of the BLACKOUT button is applied.
CROSS FADE - Also causes that function to proceed to its new value at the scene fade rate. The GRAND
MASTER and BLACKOUT controls have no effect.
BEFORE FADE - Causes that function to ignore fade rates and proceed to the new value before any fade rate is
applied to the scene.
AFTER FADE - Causes that function to ignore fade rates and proceed to the new value after any fade rate
applied to the scene has completed its transition.
CONFIG - SETTING THE CHANNEL CONFIGURATION
Each function of each fixture may be set using the CONFIG menu. Use the and keys to cycle through the
available fixture/channel selections or enter the fixture/channel number on the keypad as a 4 digit number and
push the # key. The settings for the function are shown on the lower row on the display. Use the # key to cycle
through the available selections (LAMP FADE, CROSS FADE, BEFORE FADE, and AFTER FADE.).
DEFAULT FADE - SETTING THE DEFAULT FADE TIME
This is the fade time which will be used when a scene is recorded. It is also applied when a scene is turned off if
the scene was activated manually. The time is controlled from the DEFAULT FADE menu. Enter the time as a 2
digit number on the keypad and then push the # key. Scene fade times may be altered for individually scenes
after recording the scene.
FADE RATE - SETTING THE SCENE FADE RATE
The default fade time applied to the scene when it was recorded can be altered using the FADE RATE menu.
Use the and keys to cycle through the available bank/scene selections or enter the bank/scene number on
the keypad as a 4 digit number and push the # key. The fade time is shown in the lower right of the display. To
change the fade time - enter the time as a 2 digit number and push the # key. Remember that you are setting the
rate for each scene independently.
EXIT FADE RATE
CONFIG DEFAULT FADE
MLIGHT
CONFIG
ML Fixt/Chan 01-01
ENTER Lamp Fade
DEFAULT FADE
ML Scene Default
Fade Seconds=00
FADE RATE
Before Fade
After Fade
Cross Fade
OR
Range = 0 - 99 Seconds
ML Scene Fade 00-00
SCENE 01-01 SEC=00
Control Scene Fade Time
Control Channel Configuration
Control Default
Fade Time