Function Code 32 is a master fade time function 
which will set ALL fade times to the value entered.  
You can use this for a base setting for fade times and 
then set individual scenes to other times as needed. 

 

SIMPLE REMOTE SWITCH BEHAVIOR 

 

The SR516 is very versatile in how it can respond to 
the simple remote switch inputs.  Each switch input 
can be set to operate according to its own settings. 

 

Most settings pertain to momentary switch  closures.  
The MAINTAIN setting allows the use of a regular 
ON/OFF switch.  When used this way, the applicable 
scene(s) will be ON while the switch is closed and 
OFF when the switch is open. 

 

Other scenes can still be activated and the OFF button 
will turn the MAINTAIN scene OFF. 

 

SETTING SIMPLE SWITCH INPUT OPTIONS   

(Function Codes 33 - 35) 

 

 

After accessing a function as described in 

ACCESSING AND SETTING FUNCTIONS: 

 

1.  The scene lights including 

OFF

 (0) and 

BANK

 (9) 

 

will flash a repeating pattern of the current 

 

setting. 

 

2.  Use the scene buttons to enter a value (4 digits). 
 

Use 

OFF

 for 0 and 

BANK A/B

 for 9 if needed. 

 

3.  Push 

REC

 to save the new function value. 

 

The function values and description are as follows: 

 

 

 

 

SCENE ON/OFF CONTROL 

 

0101 - 0116 Turn ON Scene (1-16) 
0201 - 0216 Turn OFF Scene (1-16) 
0301 - 0316 Toggle ON/OFF Scene (1-16) 
0401 - 0416 MAINTAIN Scene (1-16) 

 

 

 

 

OTHER SCENE CONTROLS 

 

0001  Ignore this switch input 
0002  Blackout - turn off all scenes 
0003  Recall last scene(s) 

 

 
SETTING SYSTEM CONFIGURATION OPTIONS 1 

(Function Code 37) 

 

The system configuration options are specific 
behaviors which can be turned ON or OFF. 

 

After accessing a function code (37) as described in 

ACCESSING AND SETTING FUNCTIONS: 

 

1.  The scene lights (1 - 8) will show which options 
 

are on.  An ON light means the option is active. 

 

2.  Use the scene buttons to toggle the associated 
 

option ON and OFF. 

 

3.  Push 

REC

 to save the new function setting. 

 

The configuration options are as follows: 

 

SCENE 1  

SCENE RECORD LOCKOUT 

Disables scene recording. Applies to ALL scenes. 

 

SCENE 2  

DISABLE BANK BUTTON 

Disables the Bank button. All scenes are still available 
from smart remotes if they are set to use them. 

 

SCENE 3  

SMART REMOTE LOCKOUT VIA DMX 

Disables the Smart Remotes if a DMX input signal is 
present. 

 

SCENE 4  

LOCAL BUTTON LOCKOUT VIA DMX 

Disables the SR516 scene buttons if a DMX input 
signal is present. 

 

 

SCENE 5  

SIMPLE REMOTE LOCKOUT VIA DMX 

Disables the simple remote switches if a DMX input 
signal is present. 

 

SCENE 6  

TURN ON LAST SCENE AT POWERUP 

If  a scene was active when the SR516 was powered 
off then it will turn on that scene when power is 
restored. 

 

SCENE 7   EXCLUSIVE GROUP TOGGLE DISABLE 

Disables the ability to turn off all the scenes in an 
exclusive group. It forces the last live scenes  in the 
group to stay on unless you push 

OFF

.  

 

SCENE 8  

DISABLE FADE INDICATION 

Prevents the scene lights from blinking during scene 
fade time. 

 

SETTING SYSTEM CONFIGURATION OPTIONS 2 

(Function Code 38) 

 

SCENE 1-5  SAVED FOR FUTURE EXPANSION 
SCENE 6  

MASTER/SLAVE MODE 

Changes the SR516 from transmit mode to receive 
mode when a master dimmer (ID 00), SC or SR unit is 
already in the system.  

 

Содержание SR516D

Страница 1: ...www lightronics com Lightronics Inc 509 Central Drive Virginia Beach Va 23454 757 486 3588 SR516D SR516W ARCHITECTURAL CONTROLLER Version 1 00 Date 12 16 2020...

Страница 2: ...__________________________________________________________ SR516 CONFIGURATION SETUP 6 RECORD BUTTON 6 ACCESSING AND SETTING FUNCTIONS 6 SETTING FADE TIMES 6 SIMPLE REMOTE SWITCH BEHAVIOR 7 SETTING SI...

Страница 3: ...E MAKING EXTERNAL CONNECTIONS TO THE SR516D The SR516D is provided with connectors on the rear edge of the unit for connection from a DMX controller to DMX devices remote stations and power Tables and...

Страница 4: ...be used to wire these remotes The example uses a Lightronics APP01 switch station and a typical momentary pushbutton switch If the SR516D simple switch functions are set to factory default operation...

Страница 5: ...pacitance data cable s One pair carries the data The other pair supplies power to the remote stations Multiple smart remotes of mixed type can be connected on this bus Bus connections for the smart re...

Страница 6: ...he unit RECORD BUTTON This is a very small recessed pushbutton in a small hole in the faceplate It is just below the RECORD LED labeled REC You will need a small rod such as a ball point pen or paper...

Страница 7: ...ackout turn off all scenes 0003 Recall last scene s SETTING SYSTEM CONFIGURATION OPTIONS 1 Function Code 37 The system configuration options are specific behaviors which can be turned ON or OFF After...

Страница 8: ...roup 3 Push REC to save the new group set FACTORY RESET Function Code 88 A Factory Reset will invoke the following conditions 1 All scenes will be erased 2 All fade times will be set to two seconds 3...

Страница 9: ...vation can be either exclusive only one scene may be active at a time or pile on multiple scenes on at the same time depending on setup function selections During pile on operation multiple active sce...

Страница 10: ...r serviceable parts in the unit Service by other than Lightronics authorized agents will void your warranty OPERATING AND MAINTENANCE ASSISTANCE Dealer and Lightronics factory personnel can help you w...

Страница 11: ...Page 11 of 11 SR516 ARCHITECTURAL CONTROLLER Version 1 00 OWNERS MANUAL 12 16 2020 www lightronics com Lightronics Inc 509 Central Drive Virginia Beach VA 23454 757 486 3588...

Страница 12: ...s not cover loss or damage direct or indirect arising from the use or inability to use this product F Lightronics reserves the right to make any changes modifications or updates as deemed appropriate...

Отзывы: