Lightronics RE82L Скачать руководство пользователя страница 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

Page

  

2  of  8 

RE - 82 RACK MOUNT DIMMER 

 

Revision  2.4   

 

 

 

 

 

 

OWNERS MANUAL

 

      

 

 

 

 

 

11/29/2007 

www.lightronics.com 

Lightronics Inc 

 

 

 

 

 

509 Central Drive,  Virginia Beach,  VA  23454   

 

 

 

TEL  757 486 3588 

 

 
 
 
 
 
 
 
 
 
 
 
 
DESCRIPTION 

 
The RE-82 is an 8 channel dimmer with a maximum capacity of 2,400 watts per channel giving a total of 19,200 
watts.  The RE-82 is controlled by a lighting console. The unit can be supplied to use either the DMX-512 control 
protocol or the LMX-128 control protocol.  Channels A - D and/or channels E - H may be switched to operate in 
"relay" mode.  In relay mode channels are either full on or full off (non-dim) depending on console fader position.  
The unit is overcurrent and overtemperature protected.  A fan is used to ensure proper cooling. Dimming 
channels may be reassigned in multiples of 4 channels via switches in the front panel.   
 

POWER REQUIREMENTS 

 
Each RE-82 requires BOTH PHASES of a SINGLE PHASE 120/240 VOLT AC service or TWO PHASES of a 
THREE PHASE 120/208 VOLT AC service. The neutral conductor is shared by two hots so it is important that the 
two hots used are of different phases. EACH PHASE must be capable of providing 80 AMPS. Line frequency can 
be either 50 or 60HZ. One or more RE-82 dimmers are to be installed into a standard 19" equipment rack with 
provisions for connection to an appropriate electrical service in accordance with the National Electrical Code. 
 

LIGHTING LOAD CAPACITY 

 
Each RE-82 channel has a 2400 Watt MAXIMUM rating and is protected by a fast acting 20 Amp circuit breaker.  
20 Amps equates to 2400 Watts at 120VAC. If you operate a channel at 2400 watts then you are very close to 
tripping the breaker.  This will occur if AC line voltages are high or you have power surges.  Other conditions 
which may cause the fuse to blow include turning a cold lamp quickly on to full intensity.  A maximum practical 
load of 2000 Watts per channel will allow for some overhead and help prevent breaker tripping. 
 

INSTALLATION  

 

PLACEMENT  
 
The RE-82 is designed to be mounted in a standard 19" equipment rack using the four mounting holes in the face 
plate. If the dimming system will be used for touring shows, it is recommended that you provide additional support 
for the rear of the unit. The dimmer is fan cooled and requires no space between units when multiple dimmers are 
used together in a rack. Air enters the dimmer through slots on the side and exits through holes in the bottom of 
the face plate. Make certain these ventilation holes are not obstructed. Do not place the RE-82 where it will be 
exposed to moisture or excessive heat.  
 
 
 
 
 

RE-82 CONTROL PANEL 

Содержание RE82L

Страница 1: ...www lightronics com Lightronics Inc 509 Central Drive Virginia Beach VA 23454 TEL 757 486 3588 RE 82 RACK MOUNT DIMMER 8 X 2400Watts OWNERS MANUAL Revision 2 4 11 29 2007 ...

Страница 2: ... dimmers are to be installed into a standard 19 equipment rack with provisions for connection to an appropriate electrical service in accordance with the National Electrical Code LIGHTING LOAD CAPACITY Each RE 82 channel has a 2400 Watt MAXIMUM rating and is protected by a fast acting 20 Amp circuit breaker 20 Amps equates to 2400 Watts at 120VAC If you operate a channel at 2400 watts then you are...

Страница 3: ...ch protocol can be used DMX CONTROL The DMX 512 control signal enters the RE 82 through a 5 pin XLR connector on the rear of the unit A second connector 5 pin female XLR is used to continue this control signal out to other dimmers in the system Normally the male connector is used for the incoming control signal and the female connector is used to loop out to other dimmers These connectors are wire...

Страница 4: ...st switch from the right value 4 to the up position For a starting channel of 21 move the third switch from the right value 16 and the rightmost switch value 4 to the up position MANUAL CONTROL Dimmer channels can be activated manually by pressing corresponding button switches located on the front panel This will latch the associated channel to full on Push the button again to turn the channel off...

Страница 5: ...sses are correctly set Check that the console is powered and that console channels are correctly patched or set Check the control cable between the dimmer and its console Verify the loads and their connections OWNER MAINTENANCE There are no user serviceable parts inside the unit The best way to prolong the life of your unit is to keep it cool clean and dry It is important that the cooling intake a...

Страница 6: ... ØØØØØØÃ 5 ØÃØØØØÃ 133 ÃØØØØØÃ 261 ÃÃØØØØÃ 389 ØØØØØÃØ 9 ØÃØØØÃØ 137 ÃØØØØÃØ 265 ÃÃØØØÃØ 393 ØØØØØÃÃ 13 ØÃØØØÃÃ 141 ÃØØØØÃÃ 269 ÃÃØØØÃÃ 397 ØØØØÃØØ 17 ØÃØØÃØØ 145 ÃØØØÃØØ 273 ÃÃØØÃØØ 401 ØØØØÃØÃ 21 ØÃØØÃØÃ 149 ÃØØØÃØÃ 277 ÃÃØØÃØÃ 405 ØØØØÃÃØ 25 ØÃØØÃÃØ 153 ÃØØØÃÃØ 281 ÃÃØØÃÃØ 409 ØØØØÃÃÃ 29 ØÃØØÃÃÃ 157 ÃØØØÃÃÃ 285 ÃÃØØÃÃÃ 413 ØØØÃØØØ 33 ØÃØÃØØØ 161 ÃØØÃØØØ 289 ÃÃØÃØØØ 417 ØØØÃØØÃ 37 ØÃØÃØØÃ 165 ÃØ...

Страница 7: ...es not cover loss or damage direct or indirect arising from the use or inability to use this product F Lightronics reserves the right to make any changes modifications or updates as deemed appropriate by Lightronics to products returned for service Such changes may be made without prior notification to the user and without incurring any responsibility or liability for modifications or changes to e...

Страница 8: ...www lightronics com Lightronics Inc 509 Central Drive Virginia Beach VA 23454 TEL 757 486 3588 ...

Отзывы: