background image

Castor 9

User manual

Thank you for purchasing the Lightpro Castor 9.
This document contains the required information for 
correct, efficient and safe use of the product. Consult the 
user manual of your transformer for more information 
about the installation and connection of your lighting 
plan or visit our website 

www.lightpro.nl

Read the information in this manual carefully before 
using the product. Keep this manual near the product for 
consultation in the future.

PRODUCT DESCRIPTION

The Lightpro Castor 9 is an LED spot for outdoor use. 
The fixture can be mounted on a solid surface or placed 
in the ground with the supplied spikes. This product may 
only be used as outdoor lighting in combination with 
the Lightpro 12-volt system. Any alterations made to the 
product may have consequences for the safety, guarantee 
and correct functioning of the product and/or other parts 
of the system.

SPECIFICATIONS

Product  

Lightpro Castor 9

Article number 

180S

Light source 

LED 9W AC/DC 12V

Power (max) 

9W 

Luminous flux (max) 

65 - 750 lm

Light colour 

3.000K

Average lifetime 

25.000

Dimensions (H x B x W)    95 x 60 x 120 mm 
Protection class  

IP44 

Ambient temperature  

-20 °C to 50 °C

Cable length 

1m

Dimmable 

Yes, with built-in dimmer

Light source 

Not replaceable

On/off 10.000

PACKAGING CONTENT

[Figure A]

1. Fixture Castor 9
2. Ground spike
3. Screw
4. Plug
5. Alternatieve reflector
6. Hex key (large)
7. Hex key (small)
8. Lightpro connector

 Check if all parts are present in the packaging. For 

questions about parts, service, and any complaints or 
other remarks, you can always contact us.  
E-mail:

 [email protected]

.

INSTALLATION

Option 1: placement on a fixed underground or mounting 

to a wall

 [Figure B]
1.  Remove the screw from the base using the included 

large hex key (Figure A [6]).

2. Remove the fixture from the base.

[Figure C] 
•  Install the base onto the underground with the included 

screw.

 If necessary, drill a hole in the underground and use 

the included plug.

[Figure D]
1. Place the fixture in the base.
2. Place the screw in the base.
3. Put the fixture in the desired position.
4.  Fasten the screw using the included large hex key 

(Figure A [6]).

Option 2: placement in the ground

[Figure E]
1. Place the spike underneath the base.
2. Properly fasten the spike.
3. Put the fixture in the desired position.
4.  Fasten the screw using the included large hex key 

(Figure A [6]).

5. Place the fixture in the ground.

CHANGING REFLECTOR

 The pre-installed reflector has a beam angle of 60°. If 

desired, it can be replaced by the included  
alternative reflector, which has a beam angle of 23°.

[Figure F]
1.  Remove the screw from the fixture using the  

included small hex key (Figure A [7]).

2. Remove the head from the fixture.
3. Unscrew the reflector.
4. Remove the reflector.

[Figure G]
1. Place the alternative reflector.
2. Fasten the reflector.
3.  Place the head in the fitting. Pay attention to the 

position of screw hole.

4. Place the screw in the fitting. 
5.  Fasten the screw using the included small hex key 

(Figure A [7]).

DIMMER FUNCTION 

 The fixture is equipped with a built-in dimmer. The 

light output can be set to 6 different levels.

[Figure F]
• Push the button to set the desired light output.

Содержание Castor 9 180S

Страница 1: ...eerd door Hergestellt von Produced by Produit par TECHMAR B V CHOPINSTRAAT 10 7557 EH HENGELO THE NETHERLANDS 31 0 88 43 44 517 INFO LIGHTPRO NL WWW LIGHTPRO NL Gebruikershandleiding Bedienungsanleitu...

Страница 2: ...2 A 3 4 5 8 6 7 1 2...

Страница 3: ...3 B C D 2 1 1 2 3 4 Front Back...

Страница 4: ...4 E G F H 3 2 3 4 5 3 4 1 2 1 4 2 5 1 DIMMABLE...

Страница 5: ...5 Transformer 144A 145A Connector TypeY 143A Connector Type M 138A Connector Type F 137A JUST TURN IT Connection to make a branch Connection to transformer Just twist and connect The system...

Страница 6: ...r vragen over onderdelen service eventuele klachten of andere zaken kunt u altijd bij ons terecht E mail info lightpro nl MONTAGE Optie 1 plaatsing op een vaste ondergrond of aan de wand Afbeelding B...

Страница 7: ...mationen oder anderen Angelegenheiten k nnen Sie uns jederzeit kontaktieren E Mail info lightpro nl MONTAGE Option 1 Installation auf einem festen Untergrund oder an der Wand Bild B 1 Entfernen Sie di...

Страница 8: ...packaging For questions about parts service and any complaints or other remarks you can always contact us E mail info lightpro nl INSTALLATION Option 1 placement on a fixed underground or mounting to...

Страница 9: ...e cl hexagonale 7 Petite cl hexagonale 8 Lightpro connecteur Contr lez que toutes les pi ces soient bien pr sentes dans l emballage Vous pouvez toujours nous contacter pour des questions sur les pi ce...

Страница 10: ...j uw dealer 5 jaar garantie bezoek onze website op lightpro nl voor de garantievoorwaarden INSTALLATION DER LAMPEN Installieren Sie das Produkt in der gew nschten Position und verlegen Sie die Kabel s...

Страница 11: ...c bles de telle sorte qu ils puissent tre raccord s confortablement au transformateur ou au c ble principal Si les produits sont quip s d un orifice d vacuation de l eau orientez celui ci vers le bas...

Страница 12: ...TECHMAR B V CHOPINSTRAAT 10 7557 EH HENGELO THE NETHERLANDS WWW LIGHTPRO NL UK Authorised Representative for authorities only ProductIP UK Ltd 8 Northumberland Av London WC2N 5BY Techmar B V 180S 9...

Отзывы: