background image

VOLTAGE:

120 or 277

BALLAST TYPE:

1 & 2 Lamp Mag. T12

LE

2-2 Lamp Mag. T12

LE

<

20THD

<

10THD

1 & 2 Lamp Elec. T8

SO*

H

I

*

2-2 Lamp Elec. T8

SO*

H

I

*

1-3 Lamp Elec. T8

O3*

H3*

1-4 Lamp Elec. T8

O4*

H4*

LOL T8 Dimming

PS

*

Instant Start Standard

OPTIONS:

Add appropriate suffix to

catalog no., ie: (GLR)

LAMP/

FIXTURE LENGTH:

32

=T8

34

=T12

(Nominal 48")

CLEANGUARD WET LOCATION

WES SERIES 2X4

Page 2 of 2

2' x 4' RECESSED FLUORESCENT, FOR WET LOCATIONS, COVERED CEILING USE

2, 3 OR 4 LAMP, T8 OR T12 

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902

SECTION 6/Folio N30-12

Job Information

Type:

OPTIONS & ACCESSORIES

SPECIAL LENSES:

Substitute 

VI

for 

VA

(standard) .125" nominal pattern 12

with 6.8 oz. average weight per square foot.

PLASTER FRAME: 

Catalog number: 

PF24

.

CONTINUOUS ROW INSTALLATION:

For F type fixtures, half-width flanges

are required between fixtures. Order Catalog Number: 

S2FCTRIM

(each joint).

RADIO INTERFERENCE FILTER

120 or 277 volt, 50 or 60 Hz. One per fixture

is standard. SUFFIX: 

RF

.

FUSING:

Internal fast-blow fusing. SUFFIX: 

GLR

.

Internal slow-blow fusing. SUFFIX: 

GMF

.

ELECTRICAL/WIRING OPTIONS:

Consult factory.

DRYWALL KIT:

Order Catalog Number: 

FK92X4

. Request Folio OA30-10.

CHICAGO PLENUM:

SUFFIX: 

CP

.

SPECIFICATIONS

PERFORMANCE:

In an installation of 4 lamp 32W luminaires in a room cavity

ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be
less than .85. To prevent glare the VCP shall be not less than 43 either length-
wise or crosswise (at 100fc level) and the average brightness at 65° shall not
exceed 3108 candelas per square meter. To control veiling reflections, luminaire
output in the 30°-90° zone shall not be less than 68.6%.

MATERIALS: Chassis parts

are die-formed code gauge cold rolled steel.

Housing

with side rails hemmed over and housing ends turned-in for 

safe handling. 

FINISH: Chassis exterior

—black baked polyester enamel. 

Cavity

—white

baked polyester enamel minimum 86% reflectance. Phosphate undercoating.

LENSES: VA

(standard) extruded virgin acrylic, 3/16" square based female

cones, running 45° to the panel edge, .095" nominal thickness (similar to pat-
tern 12). 

VI

(optional) .125" nominal pattern 12 with 6.8 oz. average weight per

square foot.

ELECTRICAL:

Thermally protected class “P” ballast C.B.M. approved, non PCB.

If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS:

I.B.E.W./UL and C-UL.

PHOTOMETRY

MODEL NO. WES2GFSVA432

coefficients of utilization — zonal cavity method  

(effective floor cavity reflectance 0.20)

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

89

85

82

80

78

76

77

75

73

2

82

75

70

71

67

64

68

65

62

3

75

67

61

63

58

54

61

57

53

4

69

60

53

57

51

47

55

50

46

5

64

54

47

51

45

41

50

44

41

6

59

49

42

46

41

36

45

40

36

7

55

44

37

42

36

32

41

36

32

8

51

40

34

39

33

29

38

33

29

9

48

37

31

36

30

26

35

30

26

10

45

34

28

33

28

24

32

27

24

visual comfort probability 

(rated lumens per lamp 3150.)

room size

ceiling height

ceiling height

W

L

8.5

10.0

13.0

16.0

8.5

10.0

13.0

16.0

20

20

57

62

69

77

57

60

67

75

20

30

49

54

59

66

52

54

58

64

20

40

45

49

54

59

49

51

54

57

20

60

41

45

49

54

46

49

51

54

30

20

59

63

68

75

59

62

66

73

30

30

50

54

58

64

53

55

57

62

30

40

45

49

52

56

49

51

53

55

30

60

41

44

47

51

46

48

49

52

30

80

39

42

43

47

44

46

47

50

40

20

61

65

69

74

61

64

68

73

40

30

52

56

59

64

54

57

59

62

40

40

47

50

53

56

50

52

54

56

40

60

42

45

47

50

46

49

49

51

40

80

39

42

43

46

44

47

47

49

40

100

38

40

41

44

43

45

46

47

60

30

54

58

60

64

55

58

59

63

60

40

48

51

53

57

51

53

54

56

60

60

43

45

47

50

47

49

49

51

60

80

40

42

43

46

44

46

47

49

60

100

38

40

40

43

43

45

45

47

100

40

51

54

56

59

53

55

56

59

100

60

46

48

49

53

49

51

51

53

100

80

42

44

44

48

46

48

48

50

100

100

40

42

42

44

44

46

46

47

room cavity ratio

luminaries lengthwise

luminaries crosswise

ORDERING INFORMATION

Explanation of Catalog Number.   Example: WES2GFSVA432120O4GLR

WE

CLEANGUARD

WET

LOCATION

S

STATIC

2

FIXTURE

WIDTH

CEILING TYPE:

G

= Grid (lay-in T bar)

F

=Flanged (overlap) Z spline 

and plaster frame

LENS FRAME:

FS

= Flat steel frame

RA

=Regressed 

aluminum frame

FA

=Flat aluminum

frame

LENS/SHIELDING TYPE:

VA (virgin acrylic)

standard (see options and

consult factory)

LAMP

QUANTITY:

2

=2 Lamp

3

=3 Lamp

4

=4 Lamp

Other dimming options. Consult factory.

LER = FL - 73.2

IW - 108.7

BF - 0.86

Comparative yearly lighting energy cost per 1000 lumens = $3.28