background image

VR PARABOLIC

VRA2G16LV2FT

Page 2 of 2

2'x2' RECESSED FLUORESCENT, 4" DEEP, 16 CELL (4x4) PARABOLIC LOUVER

STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902

SECTION 2/Folio G05-48 REV. A

Job Information

Type:

OPTIONS & ACCESSORIES

PLASTER FRAME:

Catalog Number: 

PF22

.

CONTINUOUS ROW INSTALLATION: 

For F type fixtures, half-width flanges are

required between fixtures, Order Catalog Number: 

S2FCTRIM

(each joint).

SPLAY TRIM:

For T ceiling type only. SUFFIX: 

CTZ22 S2  SPLAY TRIM

.

RADIO INTERFERENCE FILTER: 

120 or 277 volt, 50 or 60 Hz. One per fixture

standard. SUFFIX: 

RF

.

ELECTRICAL WIRING OPTIONS: 

Consult factory.

AIR CLOSURE STRIPS:

SUFFIX 

ACS2

(factory installed). 

DRYWALL KIT:

Order Catalog Number: 

FK92X2

. (Request Folio OA30-10.)

CHICAGO PLENUM:

SUFFIX: 

CP

.

SPECIFICATIONS

PERFORMANCE: 

In an installation of 2 lamp 40W luminaires in a room cavity

ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less
than .57 with a spacing to mounting ratio of 1.8 perpendicular to the lamps. To
meet IES RP1 preferred requirements for VDT areas the VCP (visual comfort proba-
bility) shall not be less than 92 either crosswise or lengthwise and the maximum
average brightness at 65°, 75° and 85° shall not exceed 267, 121 and 72 candelas
per square meter respectively in the 0°, 45°, and 90° horizontal planes. Candelas
at Nadir (0°) not to exceed 1224.

SPECIFICATIONS (continued)

AIR HANDLING:

(VRA only) side air passages for air supply or air return.

Optional side closure strips. Air return is also provided through the lamp com-
partment through fixture body ends.

MATERIALS: Chassis parts

are die-formed code gauge cold rolled steel.

Housing

side rails hemmed over and housing ends turned-in for safe handling.

LOUVER:

Pre-anodized aluminum (Coilzak@ or equal).

FINISH: Chassis exterior

–black baked polyester enamel. 

Cavity

–white baked

polyester enamel minimum 86% reflectance. Phosphate undercoating.

Louver

–low iridescence semi-specular anodized vertical grain aluminum reflec-

tor sheet is standard. 

ELECTRICAL:

Thermally protected class “P” ballast C.B.M. approved, non PCB.

If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS:

I.B.E.W./UL and C-UL.

PHOTOMETRY

MODEL NO. VRA2G16LV2FT

coefficients of utilization — zonal cavity method  

(effective floor cavity reflectance 0.20)

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

59

57

56

54

53

52

52

51

50

2

55

52

50

50

48

46

48

46

45

3

52

48

45

45

43

41

44

42

40

4

48

43

40

42

39

37

41

38

36

5

45

39

36

38

35

32

37

34

32

6

42

36

32

35

31

29

34

31

29

7

39

32

29

31

28

26

31

28

25

8

35

29

25

28

25

22

28

24

22

9

32

26

22

25

22

19

25

21

19

10

30

23

20

23

19

17

22

19

17

visual comfort probability 

(rated lumens per lamp 3150.)

room size

ceiling height

ceiling height

W

L

8.5

10.0

13.0

16.0

8.5

10.0

13.0

16.0

20

20

90

88

84

74

95

90

87

75

20

30

91

89

86

77

95

92

90

79

20

40

91

90

88

80

95

91

90

82

20

60

91

91

89

82

96

91

90

82

30

20

90

88

87

78

95

91

90

78

30

30

91

90

88

80

96

92

92

82

30

40

91

91

90

82

96

92

92

84

30

60

92

91

91

84

96

92

92

84

30

80

92

91

91

84

96

92

92

84

40

20

90

88

87

80

95

91

90

81

40

30

91

90

89

82

96

92

92

84

40

40

92

91

90

84

96

92

92

86

40

60

92

91

91

85

96

92

92

86

40

80

92

91

91

86

96

92

92

86

40

100

92

91

91

86

96

92

92

86

60

30

92

90

89

82

96

92

92

84

60

40

92

91

90

84

96

92

92

86

60

60

92

91

91

86

96

92

92

86

60

80

92

91

91

86

96

92

92

86

60

100

92

91

91

86

96

92

92

86

100

40

92

91

90

84

96

92

92

86

100

60

92

91

91

86

96

92

92

86

100

80

92

91

91

86

96

92

92

86

100

100

92

91

91

86

96

92

92

86

room cavity ratio

luminaries lengthwise

luminaries crosswise

ORDERING INFORMATION

Explanation of Catalog Number.   Example: VRA2G16LV2FT120SBGLR

LER = FP - 39.0

WATTS - 69.0

BF - 0.82

Comparative yearly lighting energy cost per 1000 lumens = $6.15

VR

VR:

4" Deep

Pre-anodized

Aluminum

Louver

For Normal

VDT Use

BODY STYLE:

A=

Air Handling

S

=Static

2

FIXTURE

WIDTH

CEILING TYPE:

G

= Grid

(lay-in T bar)

F

=Flanged

(overlap)

Z spline and
plaster frame

T

=Slot grid or       

two-directional
concealed T
(see options)

16

NUMBER OF

CELLS:

(4 rows of

4 cells)

LOUVER

FINISH*:

L

=Low

Iridescence
Semi-specular
(standard)

P

=Low

Iridescence
Specular

V

SINGLE “V”
REFLECTOR

2

LAMP

QUANTITY

FT

LAMP TYPE/

FIXTURE

LENGTH:

Twin Tube T5

(Nominal 24")

VOLTAGE:

120 or 277

OPTIONS:

Add appropriate
suffix to catalog

no, ie: (

GLR

)

BALLAST TYPE:

<

20THD

<

10THD

1-2 Lamp Elec. TT5

(40 watt)

SB*

I

B*

LOL TT5 Dimming

PB

*

Instant Start Standard

Other dimming options. Consult factory.