© 1997
INSTRUCTION SHEET NO.
Fig. E
IS:7480
B1197
Page 2 of 2
Installation Instructions for Stem Mounting Kit
for use with Lytespan and ProSpec
™
Track Systems Only.
Fig.D-1
Basic Track
Individual
Track Unit
Screw
Sidewall
Bottom Cover
Live End
Advent Track
Wireway Cover
Track Rib
Center Barrier
Broken Off
Live End
Supply
Leads
Bottom Cover
Screw
Wireway Cover
Track Clamp
Track Unit
Bead
Track Rib
Stem
Screw
Center Barrier
Stem
Coupling
Supply Leads
Fig. D-3
Fig. D-2
Wireway Cover
Track Rib
Bead
Bead
Wireway Cover
Track Rib
ProSpec Track
for splicing, and enough wire to run horizontally along upper
section of track to power feed-in point, plus additional wire for
attaching to power feed connections. Slide Upper Swivel Housing
over Supply Leads and Swivel Casting Assembly. Feed Supply
Leads through Neck Wireway. Attach Upper Swivel Housing and
Swivel Casting Assembly to Neck Wireway, by driving Longer Set
Screw into Upper Swivel Housing and through the hole in the front
of the casting until you engage the hole in the Neck Wireway.
(Fig. C).
4. Splice Supply Leads to branch circuit wiring in outlet box. White to
white, black to black (red to red in Advent). Attach 12 AWG Branch
Circuit ground wire between washer and green screw on Mounting
Plate. (Fig. C.)
5. Fasten Stem Mounting Plate to Outlet Box with Outlet Box Screws.
Place Canopy over assembly and Mounting Screws. Secure with
Cap Screws until Canopy rest tight against ceiling.
6. Pass supply leads through unthreaded end of stem. Slide stem into
Swivel casting Assembly and drive Set Screw through hole on the
side of casting until tight. Slide Lower Swivel Housing over Stem
and onto Swivel Casting Assembly. Drive Set Screw into Lower
Swivel Housing and through hole in the front of casting until Stem
is held tight.
7. Drive Flat Head Screws into Track Clamps. Screw Track Clamps
onto bottom of Stem. (See Figs. C and E.)
C. Mounting Track Units onto Stems
1. Loosen Screws on Track Clamps. For feed stem, the Track Clamp
must be positioned as shown in Fig.D-1. Place Track Ribs (Fig. D-3)
between Track lamps and slide track into position. Make sure Bead
(Fig. D-3) of Track Units are in-line with one another when using
more than one Track Unit..
2. Run Supply Leads along top of track toward Live End. Loosed screw
in Live End and remove from track.
3. Cut Wireway Cover to distance from Track Clamp to end of Track
Unit. Slide Wireway Cover into track over Supply Leads. (Fig. D-1,
D3).
4. Remove Bottom Cover from Live End.
5. Break off Barrier in Live End by bending it back and forth. (Fig. D-2)
6. Pass Supply Leads through Barrier opening in Live End. Insert Live
End into Track Unit and tighten Screw. For ProSpec feed track
place wire cover into track before attaching the stems to the track
unit.
7. Connect Supply Leads to screw terminals as shown in Instruction
Sheet IS:6020, IS:6121, for Advent, or IS:26000, IS:26046, IS:26050
for ProSpec. Ground terminal in Live End is not used when feeding
power from a Stem.
8. Fasten Bottom Cover to Live End. Tighten Screws on all Track
Clamps.
D. Instructions for Stem Extension Kits
1. Screw Coupling to threaded end of Stem supplied with Stem
Mounting Kit (Fig. E).
2. Screw Stem supplied with Stem Extension Kit to Coupling (Fig. E).
3. Complete installation of Stem Mounted Lytespan Track following
steps in B.
Feed Track
Barrier
Barrier