![Lightolier Specplus SPS2GFSVA432 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/lightolier/specplus-sps2gfsva432/specplus-sps2gfsva432_specification_1914209002.webp)
Ballast Type:
<
20THD
<
10THD
2-2 Lamp Elec. T8
SO *
H
I
*
1-4 Lamp Elec. T8
O4 *
H4 *
2-2 Lamp 28W Elec. T5
–
P
I
†
2-2 Lamp 28W Elec. T5
–
†
PG ††
1-4 Lamp 54W Elec. T5
–
†
PV ††
LOL T8 Dimming
PS
–
Other dimming options. Consult factory.
†
*Instant Start Standard
†
†Instant Start (120, 277 or
UNV
)
††Program Rapid Start
(UNV
only)
NOTE:
For
T8 UNV
, you must use
H
I
,
H4
Ballast Code.
Specplus
SPS2GFSVA432
Page 2 of 2
2' x 4' Recessed Fluorescent, Lens Frame Troffer
Static, 4 Lamp T8 or T5
Ordering Information
Explanation of Catalog Number. Example: SPS2GFSVA432UNVH4
Options/Accessories
Special Lenses
: Substitute
VY
for
VA
(standard) = .125" nominal pattern 12 with 7.8 oz. average weight per
square foot. Substitute
VI
for
VA
(standard) = .125" nominal pattern 12 with 6.8 oz. average weight per
square foot. Substitute
S1
or
S2
for
VA
(standard) = Sky Acrylic Lens (see Sky Lens sell sheet for
further details).
Plaster Frame
: Catalog Number:
PF24
.
Continuous Row Installation
: For F type fixtures, half width flanges are required between
fixtures. Order Catalog Number:
2FC TRIM CSP
(each joint).
Radio Interference Filter
: To order one RIF per fixture; SUFFIX:
R
.
To order one RIF per ballast; SUFFIX:
B
.
Fusing
: Internal fast-blow fusing. SUFFIX
A
.
Internal slow-blow fusing. SUFFIX
C
.
Electrical Wiring Options
: Consult factory.
Drywall Kit
: Order Catalog Number:
FK92X4
. (Request Folio OA30-10 Rev. A).
Chicago Plenum
: SUFFIX:
C
.
Specifications
Performance
: In an installation of 4 lamp 32W luminaires in a room cavity ratio of 1, reflectance
80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .85. To prevent glare the VCP shall
be not less than 43 either lengthwise or crosswise (at 100fc level) and the average brightness at 65°
shall not exceed 3108 candelas per square meter. To control veiling reflections, luminaire output in
the 30°-90° zone shall not be less than 68.6%.
Specifications (continued)
Materials
:
Chassis parts
are die-formed code gauge cold rolled steel. Housing with side rails hemmed
over and housing ends turned-in for safe handling.
Finish
:
Chassis exterior
–black baked polyester enamel.
Cavity
–white baked polyester enamel
minimum 86% reflectance. Phosphate undercoating.
Lenses
:
VA
(standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the
panel edge, .095" nominal thickness (similar to pattern 12).
VY
(optional) .125" nominal pattern 12
with 7.8 oz. average weight per square foot.
VI
(optional) .125" nominal pattern 12 with 6.8 oz. aver-
age weight per square foot.
Electrical
: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
Labels
: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp.
Manage in accord with Disposal Laws. See: www.lamprecycle.org
Specplus:
Recessed
fluorescent
troffer
S
Static
2
Fixture
Width
Lens Frame:
FS
= Flat steel
frame.
RA
= Regressed
aluminum
frame.
FA
= Flat aluminum
frame.
Lens Shielding
Type:
VA
=Virgin acrylic
(standard)
S1
=Sky lens 1
S2
=Sky lens 2
See options and
consult factory
4
Lamp
Quantity
Options:
Add appropriate suffix
to catalog no., ie: (A)
Voltage:
120, 277 or
UNV
=120-277
Lamp Type/
Fixture Length:
32
=32W T8
28
=28W T5
54
=54W T5
(Nominal 48")
SP
Standard Specplus Plus
SX
For NYC Code – Local 3 Manufactured
Ceiling Type:
G
= Grid
(lay-in T bar)
F
= Flanged (over
lap) Z spline and
plaster frame
0.0
45.0
90.0
FLUX
0
3690
3690
3690
5
3673
3678
3685
350
15
3546
3580
3612
1012
25
3270
3353
3430
1545
35
2814
2948
3056
1839
45
2192
2316
2457
1784
55
1410
1515
1613
1349
65
770
765
853
790
75
440
335
390
420
85
178
152
139
168
90
0
0
0
Model No. SPS2GFSVA43212004
LER = FP - 73.2
IW - 108.7
BF - 0.86
Comparative yearly lighting energy cost per
1000 lumens = $3.28
Report Number: ITL49786
Catalog Number: SPS2GFSVA43212004
Lamps: (4) F32T8
Luminaire: 2' x 4' SpecPlus with regressed
aluminum door frame and extruded
virgin acrylic shielding .095" nominal
thickness (similar to pattern 12).
Ballast: E423PI120G11
Report is based on 2850 Lumens per lamp.
Efficiency: 81.2%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.3
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
46.000
21.875
CANDELA DISTRIBUTION
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 89 85 82 80 78 76 77 75 73
0
2 82 75 70 71 67 64 68 65 62
0
3 75 67 61 63 58 54 61 57 53
0
4 69 60 53 57 51 47 55 50 46
0
5 64 54 47 51 45 41 50 44 41
0
6 59 49 42 46 41 36 45 40 36
0
7 55 44 37 42 36 32 41 36 32
0
8 51 40 34 39 33 29 38 33 29
0
9 48 37 31 36 30 26 35 30 26
10 45 34 28 33 28 24 32 27 24
Job Information
Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
02/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
Section 1A/Folio E60-34 Rev. B
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
4773.
5043.
5351.
55
3785.
4067.
4330.
65
2806.
2787.
3108.
75
2618.
2112.
2320.
85
3145.
2685.
2456.
LUMINANCE DATA IN CANDELA/SQ. METER
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
2906
25.5
31.4
0
0-
0
40
4745
41.6
51.3
0
0-
0
60
7878
69.1
85.1
0
0-
0
90
9257
81.2
100.0
90-180
000
0
0.0
00
0.0
0
0-180
9257
81.2
100.0
ZONAL LUMEN SUMMARY
Photometry
Sky Lens Options
S1
S2