Sidemount Strip

SM STRIP 

Page 2 of 2

4-1/8" WIDE, 1-13/16" DEEP, 24", 36", 48" LENGTHS, 1 OR 2 LAMP, T8 OR T12

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902

Section 3A/Folio H120-15

Job Information

Type:

ORDERING INFORMATION  

Explanation of Catalog Number.   Example: SM234HPF120LEGLR

SM

SIDEMOUNT

STRIP

LAMP

QUANTITY:

1 or 2 Lamp

LAMP:

(By Others)

17

=(T8), 2' Length

20

=T12, 2' Length

25

=T8, 3' Length

30

=T12, 3' Length

32

=T8, 4' Length

34

=T12, 4' Length

BALLAST TYPE:

LPF

=Low Power

Factor

HPF

=High Power

Factor

BALLAST:

1 or 2 Lamp Mag. (T12)

LE

Standard Electro Magnetic
(20 or 30 watts only)

P

<20THD <10THD

1 or 2  Lamp Elec. (T8)

SO*

H

I

*

LOL Dimming (T8)

PS

*

Instant Start Standard

Other dimming options. Consult factory.

OPTIONS:

Add appropriate
suffix to catalog

no., ie: (GLR)

VOLTAGE:

120 or 277

PHOTOMETRY

MODEL NO. SM234HPF120LE

coefficients of utilization — zonal cavity method  

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

92

87

82

67

64

61

55

53

51

2

83

75

68

57

53

49

47

44

41

3

75

65

57

50

45

41

41

37

34

4

68

57

49

44

39

34

36

32

29

5

63

51

42

39

34

29

32

28

25

6

58

45

37

35

30

25

29

25

21

7

53

41

33

32

26

22

26

22

19

8

49

37

29

29

23

19

24

20

17

9

46

34

26

27

21

17

22

18

15

10

43

31

24

24

19

16

20

16

13

room cavity ratio

REPORT NO.:

G14162

DATE.:   8/14/91

CATALOG NO.:

SM234HPF120LE

LAMP(S):

2 F40 , EACH RATED   3150 LUMENS

EFFICIENCY;

95.8%

LUMINAIRE:

SIDE MOUNTED STRIP, MAGNETIC

WATTS:  

82.0

CANDELA DISTRIBUTION

FLUX

0.0

45.0

90.0

0

0

819

819

819

0

5

815

814

812

77

15

787

785

791

222

25

731

741

752

341

35

650

673

694

420

45

545

586

628

452

55

422

492

561

440

65

286

400

497

392

75

150

323

462

334

85

41

288

443

291

95

42

276

428

284

ZONAL LUMEN SUMMARY
ZONE

LUMENS

%LAMP

%FIXT

0

0-

0

30

641

10.2

10.6

0

0-

0

40

1061

16.8

17.6

0

0-

0

60

1954

31.0

32.4

0

0-

0

90

2971

47.2

49.3

90-180

3061

48.6

50.7

0

0-180

6033

95.8

100.0

LUMINANCE DATA IN CANDELA/SQ M
ANGLE

AVERAGE

AVERAGE

AVERAGE

IN DEG

0-DEG

45-DEG

90-DEG

45

4703

3870

3855

55

4400

3589

3730

65

3916

3373

3728

75

3129

3348

4118

85

1918

4031

5055

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD

PERFORMANCE MAY DIFFER FROM LABORATORY PEFORMANCE.

1-13/16"

(46mm)

5-11/16"
(145mm)

TWO LAMP

LER = FS - 69.9   Watts - 82   BF - 0.95
Comparative yearly lighting energy cost per 1000 lumens = $3.43

OPTIONS & ACCESSORIES

FUSING:

Internal fast-blow fusing. 
SUFFIX: 

GLR

.

Internal slow-blow fusing. 
SUFFIX: 

GMF

.

ELECTRICAL/WIRING OPTIONS:

Consult factory.

RADIO INTERFERENCE FILTER:

120 or 277 volt, 50 or 60 Hz. 

One per fixture. SUFFIX: 

RF

.

STEM AND CANOPY SETS: 

Suspends fixture 6", 12", 18" or 24" from surface.

Catalog Number: 

ASC6 CSP

(6"), 

ASC12 CSP

(12"), 

ASC18 CSP

(18"), 

ASC24 CSP

(24").

SPECIFICATIONS:

MATERIALS: Chassis parts

are die-formed code gauge cold rolled steel, 1-

13/16" deep x 2-1/2" channel width.

BALLAST: Cover

–code gauge cold rolled steel, secured by quarter-turn 

latches.

FINISH: Chassis exterior

–baked white polyester

enamel, minimum reflectance 86%. 

ELECTRICAL:

Thermally protected class “P” ballast C.B.M. approved, non PCB.

If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS:

I.B.E.W./UL and ULc Listed.