background image

Job Information 

Type:

"JSQPSU3PBE'BMM3JWFS."t t'BY 

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt

Lighting Systems

 PTS6-2

1BHFPG

1FSJNFUFS5SPVHI3FDFTTFE-JHIU51FS /PNJOBM4FDUJPO

$

End Cap Set:

PTSEP

12”

(30.48c

m

)

1 3/4"

(4.45c

m

)

90° Inside Corner:

90° Outside Corner:

6 1/4"

(15.88c

m

)

135° Inside Corner:

PTS6135INCO - Open
PTS6135INCL - Lens
PTS6135INCS - Straight
Blade Louver

2"

(5.08c

m

)

135° Outside Corner:

PTS6135OTCO - Open
PTS6135OTCL - Lens 
PTS6135OTCS - Straight
Blade Louver 

PTS69ØINCO - Open
PTS69ØINCL - Lens 
PTS69ØINCS - Straight
Blade Louver 

PTS69ØOTCO - Open
PTS69ØOTCL - Lens 
PTS69ØOTCS -Straight
Blade Louver 

End Plate and Corner Block Accessories

Sample Run

For Fixture Using Staggered Lamps

The Four-Foot Adjustable Staggered Fixture has a range of 51”(129.54c

m

) - 60”(152.40c

m

).

The Three-Foot Adjustable Staggered Fixture has a range of 39”(99.06c

m

) - 48”(121.92c

m

).

The Two-Foot Adjustable Staggered Fixture has a range of 27”(68.58c

m

) - 36”(91.44c

m

).

For Fixture Using non-Staggered Lamps

The Four-Foot Adjustable Fixture has a range of 48.75”(123.83c

m

) - 60”(152.40c

m

).

The Three-Foot Adjustable Fixture has a range of 36.75”(93.35c

m

) - 48”(121.92c

m

).

The Two-Foot Adjustable Fixture has a range of 24.75”(62.87c

m

) - 36”(91.44c

m

).

6' (182.88c

m

)

4' (121.92c

m

)

Three-Foot A¹ 

8' (243.84c

m

)

Three-Foot A¹ 

6' (182.88c

m

)

Three-Foot A¹ 

3' (91.44c

m

)

Three-Foot A¹ 

4' (121.92c

m

)

1 3/4"

(4.45c

m

)

1 3/4"

(4.45c

m

)

¹ 

A = Adjustable Fixture or Adjustable Staggered Fixture

21' - 10 3/4" (667.39c

m

)

9' - 3 1/4" (282.58c

m

)

7' - 10 1/2"
(240.03c

m

)

7' - 10 1/2"
(240.03c

m

)

1’ (30.48c

m

)

Fixture used at

3’ - 10 3/4”

(118.75c

m

)

Fixture used at

3’ - 3 1/4”

(99.70c

m

)

Fixture used at

3’ - 10 1/2”

(118.11c

m

)

Fixture used at

3’ - 10 1/2”

(118.11c

m

)

Floor cavity reflectance = 20%

Performance & Quick Calculators

1600

1200

800

400

-30

-20

-10

30

40

50

60

70

80

90

20

10

0

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

% WALL REFLECTANCE

70

50 30

70

50

30

50

30

10

0

55

55 55

54

54

54

52

52

52

1

51

48 47

49

47

46

45

44

43

2

46

42 39

45

42

39

40

38

35

3

42

37 34

41

37

33

35

32

30

4

39

33 29

38

33

29

21

28

26

5

36

30 26

5

29

25

28

25

22

6

33

27 23

32

26

23

26

22

20

7

31

24 20

30

24

20

23

20

17

8

29

22 18

28

22

18

21

18

16

9

27

21 17

26

20

14

20

16

14

10

25

19 15

24

19

15

18

15

13

180

0

175

0

165

0

155

0

145

0

135

0

125

0

115

0

105

0

95

0

90

64

56

0

85

142

96

17

17

0

75

603

241

83

78

33

65

891

401

163

155

130

55

1540

521

262

252

245

45

1608

807

417

372

382

35

1481

957

641

519

516

25

1315

1037

832

695

675

15

1257

1174

997

884

854

5

1207

1193

1113

1066

1042

0

1134

1134

1134

1134

1134

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% BARELAMP % LUMINAIRE

0-90

2742

46.5

100.0

90-180

0.0

0.0

0.0

0-180

2742

46.5

100.0

Report No: 

ITL53556

Cat No: 

PTS62S14

Lamps: 

2 F32T8

Lumens: 

2950

Efficiency: 

46.5%

ROOM CA

VITY RA

TIO

0
0
0
0
0
0
0
0
0
0
0

0
0
0
0
0
0
0
0
0
0
0

0
0
0
0
0
0
0
0
0
0

0
0
0
0
0
0
0
0
0
0

CANDLEPOWER

DEG.

ZONE

0

45

180

135

90

Отзывы: