background image

Job Information 

Type:

"JSQPSU3PBE'BMM3JWFS."t t'BY 

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt

Lighting Systems

 PTS6-1

1BHFPG

1FSJNFUFS5SPVHI3FDFTTFE-JHIU51FS /PNJOBM4FDUJPO

$

End Cap Set:

PTSEP

12”

(30.48c

m

)

1 3/4"

(4.45c

m

)

90° Inside Corner:

PTS69ØINCO - Open
PTS69ØINCL - Lens 
PTS69ØINCS - Straight
Blade Louver 

90° Outside Corner:

PTS69ØOTCO - Open
PTS69ØOTCL - Lens 
PTS69ØOTCS -Straight
Blade Louver 

6 1/4"

(15.88c

m

)

135° Inside Corner:

PTS6135INCO - Open
PTS6135INCL - Lens
PTS6135INCS - Straight
Blade Louver

2"

(5.08c

m

)

135° Outside Corner:

PTS6135OTCO - Open
PTS6135OTCL - Lens 
PTS6135OTCS - Straight
Blade Louver 

End Plate and Corner Block Accessories

Sample Run

For Fixture Using Staggered Lamps

The Four-Foot Adjustable Staggered Fixture has a range of 51”(129.54c

m

) - 60”(152.40c

m

).

The Three-Foot Adjustable Staggered Fixture has a range of 39”(99.06c

m

) - 48”(121.92c

m

).

The Two-Foot Adjustable Staggered Fixture has a range of 27”(68.58c

m

) - 36”(91.44c

m

).

For Fixture Using non-Staggered Lamps

The Four-Foot Adjustable Fixture has a range of 48.75”(123.83c

m

) - 60”(152.40c

m

).

The Three-Foot Adjustable Fixture has a range of 36.75”(93.35c

m

) - 48”(121.92c

m

).

The Two-Foot Adjustable Fixture has a range of 24.75”(62.87c

m

) - 36”(91.44c

m

).

6' (182.88c

m

)

4' (121.92c

m

)

Three-Foot A¹ 

8' (243.84c

m

)

Three-Foot A¹ 

6' (182.88c

m

)

Three-Foot A¹ 

3' (91.44c

m

)

Three-Foot A¹ 

4' (121.92c

m

)

1 3/4"

(4.45c

m

)

1 3/4"

(4.45c

m

)

¹ 

A = Adjustable Fixture or Adjustable Staggered Fixture

21' - 10 3/4" (667.39c

m

)

9' - 3 1/4" (282.58c

m

)

7' - 10 1/2"
(240.03c

m

)

7' - 10 1/2"
(240.03c

m

)

1’ (30.48c

m

)

Fixture used at

3’ - 10 3/4”

(118.75c

m

)

Fixture used at

3’ - 3 1/4”

(99.70c

m

)

Fixture used at

3’ - 10 1/2”

(118.11c

m

)

Fixture used at

3’ - 10 1/2”

(118.11c

m

)

Floor cavity reflectance = 20%

Performance & Quick Calculators

980

735

490

245

-30

-20

-10

30

40

50

60

70

80

90

20

10

0

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

% WALL REFLECTANCE

70

50 30

70

50

30

50

30

10

0

57

57 57

56

56

53

53

53

53

1

53

50 48

51

49

47

47

46

44

2

48

44 41

47

43

40

42

39

37

3

44

39 35

43

38

35

37

34

31

4

40

35 31

39

34

30

33

30

27

5

37

31 27

36

31

27

30

26

23

6

34

28 24

33

28

24

27

23

21

7

32

26 21

31

25

21

24

21

18

8

30

23 19

29

23

19

22

16

16

9

28

21 17

27

21

17

21

17

15

10

26

20 16

25

19

16

19

16

13

0
0
0
0
0
0
0
0
0
0

31

28

0

76

49

0

197

153

43

41

18

0
0
0
0
0
0
0
0
0
0

0
0
0
0
0
0
0
0
0
0

280

228

84

77

64

702

284

133

126

118

900

498

209

184

179

977

585

312

253

247

822

591

404

329

324

689

621

480

409

395

607

589

536

501

484

541

541

541

541

541

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% BARELAMP % LUMINAIRE

0-90

1420

48.1

100.0

90-180

0.0

0.0

0.0

0-180

1420

48.1

100.0

Report No: 

ITL53555

Cat No: 

PTS61S14

Lamps: 

1 F32T8

Lumens: 

2950

Efficiency: 

48.1%

ROOM CA

VITY RA

TIO

0
0
0
0
0
0
0
0
0
0
0
9

0
0
0
0
0
0
0
0
0
0
0
9

CANDLEPOWER

DEG.

180
175
165
155
145
135
125
115
105

95
90
85
75
65
55
45
35
25
15

5
0

ZONE

0

45

180

135

90

Отзывы: