background image

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902

Section 3A/Folio H50-18 REV. A

Job Information

Type:

OPTIONS & ACCESSORIES

FUSING:

Internal fast-blow fusing.
SUFFIX: 

GLR

.

Internal slow-blow fusing.
SUFFIX: 

GMF

.

RADIO INTERFERENCE FILTER

120 or 277 volt, 50 or 60 Hz. One per fixture

is standard. SUFFIX: 

RF

.

ELECTRICAL/WIRING OPTIONS

Consult factory. 

STEM AND CANOPY SETS:

Suspends fixture 6", 12", 18" or 24" from surface.

(Four per fixture is required.) 

Catalog Number: ASC6 CSP

(6"), 

ASC12 CSP

(12"), 

ASC18 CSP

(18"), 

ASC24 CSP

(24").

SPECIFICATIONS

PERFORMANCE:

In an installation of 2 lamp 31W luminaires in a room cavity

ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be
less than .61. To prevent glare the VCP shall not be less than 57 either length-
wise or crosswise (at 100 fc level) and the average brightness at 65° shall not
exceed 575 footlamberts. To control veiling reflections, luminaire output in the
30° - 90° zone shall be not less than 65.5%.

SPECIFICATIONS (continued)

MATERIALS: Chassis parts 

are die-formed 20 gauge cold rolled steel, stud-

welded for rigidity. 

Lens Frame

—(

FA

) flush full-size aluminum frame, (

FS

)

flush full-size steel frame, (

RA)

regressed full-size aluminum frame, (

RF

) 1/2"

regressed floating aluminum frame with 7/16" black reveal, four sides.

FINISH: Chassis exterior

—white baked acrylic enamel. 

Cavity

—white

baked acrylic enamel minimum reflectance 86%. Phosphate undercoating.

Lens

—extruded virgin acrylic, 3/16" square based female cones, running 45°

to the panel edge, .095" nominal thickness (similar to pattern 12).

ELECTRICAL:

Thermally protected class “P” ballast C.B.M. approved, non PCB.

If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS:

I.B.E.W./UL and C-UL.

PRISMALYTE (PNB)

PNB SERIES 2U/6U/FT/17

Page 2 of 2

2'x2' SURFACE BOX FLUORESCENT, PREMIUM SPECIFICATION GRADE LENSED

2, 3 OR 4 LAMP, T8, TT5, OR T12 

PHOTOMETRY

MODEL NO. PNB2SFAVA26U120SO

ORDERING INFORMATION  

Explanation of Catalog Number.   Example: PNB2SFAVA26U120SOGLR

PN

PRISMALYTE

:

Lens Frame

Surface

Fluorescent

B

BODY STYLE:

Surface Box

2

FIXTURE

WIDTH

S

CEILING

TYPE:

S

=Surface

LENS FRAME:

FA

= Flush full-size

aluminum
frame

FS

=Flush full-size

steel frame

RA

=Regressed

full-size
aluminum
frame

RF*

=1/2" 

regressed
floating
aluminum
frame

LENS/

SHIELDING

TYPE:

VA

=Virgin

acrylic
(standard)
See
specifications
and consult
factory

LAMP

QUANTITY:

(By Others)

2

=2 Lamp

3

=3 Lamp

4

=4 Lamp

(T8, 2'

Lamp
Only)

LAMP/

FIXTURE LENGTH:

6U

= 6"U Lamp T8 or 

T12

2U

= T8, 1-5/8" U Lamp

FT

= Twin Tube T5

17

= T8, 2' Lamp

(Nominal 24")

VOLTAGE:

120 or 277

OPTIONS:

Add appropriate suffix

to catalog no., ie: (GLR)

*With 7/16" black reveal four sides.

coefficients of utilization — zonal cavity method  

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

64

61

59

58

56

55

56

54

53

2

59

55

52

52

50

48

50

48

46

3

55

50

46

47

44

42

46

43

41

4

51

45

40

43

39

36

41

38

36

5

47

40

36

38

35

32

37

34

32

6

43

36

32

35

31

28

34

31

28

7

40

33

28

32

28

25

31

27

25

8

37

30

25

29

25

22

28

24

22

9

34

27

22

26

22

19

25

22

19

10

32

24

20

23

20

17

23

19

17

visual comfort probability 

room size

ceiling height

ceiling height

W

L

8.5

10.0

13.0

16.0

8.5

10.0

13.0

16.0

20

20

67

71

77

82

66

69

75

78

20

30

61

64

70

74

60

63

68

71

20

40

59

61

65

68

57

59

63

66

20

60

58

60

61

63

55

57

59

62

30

20

67

72

77

80

67

71

75

78

30

30

61

64

69

72

61

63

67

70

30

40

58

60

63

66

57

59

62

64

30

60

57

58

59

61

55

56

57

60

30

80

57

58

57

59

55

55

55

57

40

20

69

73

77

80

68

72

76

78

40

30

62

65

69

72

62

64

67

70

40

40

58

60

63

66

58

60

62

64

40

60

57

58

58

60

56

57

57

59

40

80

57

57

56

58

55

56

55

56

40

100

59

58

56

57

56

56

54

55

60

30

63

66

69

72

63

65

68

71

60

40

60

61

63

66

60

61

62

64

60

60

58

58

57

60

57

57

57

59

60

80

58

57

55

57

56

56

54

56

60

100

59

57

55

56

57

56

53

54

100

40

63

64

65

68

63

64

64

67

100

60

61

61

59

61

61

60

59

61

100

80

61

59

56

58

60

59

56

57

100

100

61

59

55

56

60

58

55

55

room cavity ratio

luminaries lengthwise

luminaries cr

osswise

BALLAST TYPE:

1 & 2 Lamp Mag. T12

LE

1-2 Lamp Mag.

LE

<20THD <10THD

1 & 2 Lamp Elec

SO*

H

I

*

1-2 Lamp Elec. T8

SO*

H

I

*

1-2 Lamp Elec. TT5

SB*

IB*

(40 Watt)

1-3 Lamp Elec. T8

O3*

H3*

1-3 Lamp Elec. TT5

X3*

I

3*

1-4 Lamp Elec. T8

O4*

H4*

LOL Dimming T8

PS

LOL Dimming TT5

PB

*

Instant Start Standard

Other dimming
options. Consult
factory.

G92067
PNB2SFAVA26U120SO

Отзывы: