Features

• Three lighting functions with intregral ambient, reading and optional

nurse's night light.

• Precise light control for glare free patient environment.
• Installs as a one-piece unit.
• Recessed or surface mounted to ceiling against wall which elimi-

nates damage to fixture from hospital equipment attached to bed.

• 6-7/8" deep.
• All lamps are enclosed.
• All twin tube T5 lamps are accessible for relamping without tools.
• Optional low voltage electronic sequential switch mounted in fixture

for ambient and reading light controlled with pillow speaker
(optional by others).

• Optional night light.
• Meets NYC Code requirements. Chicago Plenum requirements

available.

Job Information

Type:

Job Name:
Cat. No.:

Lamp(s):
Volts/Ballast:

4/07

   

MD*4 2' x 2' Recessed or Surface 

MD2G2SB

Page 1 of 4

Multi-Function Patient Lighting

Lightolier 

a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company

Section 8/Folio R40-12 Rev. B

S

Surface

G

exposed T-grid ceiling

MOUNTING METHODS

DIMENSIONS

1. Reading light with low iridescence anodized semi-specular aluminum reflector.
2. Extruded aluminum lamp baffle.
3. Ambient light with low iridescence anodized semi-specular aluminum reflector.
4. Twin tube T5 lamps (2).
5. Clear acrylic lens.
6. Ballast compartment.

1

2

3

4

5

Ceiling

Wall

Secure fixture
(4 places)

48"

Wall

Wall angle

or T-bar

by others

6-7/8"

(175mm)

24"

(610mm)

5

4

2" x 3" access plate with

(2) 7/8" dia. K.O.s

Tabs for wire

supports
(4 places)

Mounting holes (4)

14"

(356mm)

4-7/8" (124mm

19-11/16" (500mm)

23-3/4" (603mm)

2-1/32"
(52mm)

23-3/4"

(603mm)

12-3/4"

(324mm)

4" (102mm)

2-1/32"
(52mm)

6

Acoustical Tile

(by others)

 

Содержание MD2G2SB

Страница 1: ... Function Patient Lighting Lightolier a Genlyte company www lightolier com Technical Information 978 657 7600 Fax 978 658 0595 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2007 a Genlyte company Section 8 Folio R40 12 Rev B S Surface G exposed T grid ceiling MOUNTING METHODS DIMENSIONS 1 Reading light with ...

Страница 2: ...ors 7 footcandles maximum at head of bed 15 footcandles maximum at foot of bed Controls light directly onto patient s bed No reading light spill over to adjacent bed 2 foot candles maximum at head of adjacent patient s bed MD 4 2 x 2 Recessed or Surface MD2G2SB Page 2 of 4 Multi Function Patient Lighting Illumination at the reading task range 50 60 footcandles READING LIGHT ON ADJACENT MD 4 OFF FO...

Страница 3: ...e with that manufacturers pillow speaker The pil low speaker is used to control the television call the nurse and control the lighting To control the lighting it should be specified to have a normally open contact switch Pressing this switch on the pillow speaker the first time turns the ambient light on pressed a second time turns the reading light on and the ambient light off pressed a third tim...

Страница 4: ...0 Labels I B E W UL and ULc Listed This product may have a mercury containing lamp Manage in accord with Disposal Laws See www lamprecycle org Options Accessories Access Plates Top wiring access plate is shipped with fixture as standard When access plates are required in advance for wiring convenience specify separately Catalog Number ACP Drywall Kit or Plaster Ceiling Order Catalog Number FK92X2 ...

Отзывы: