background image

Ambient Light

Indirect illumination from wall directly behind patient provides glare-free lighting.
No direct glare to patient. (Light is directed towards wall.)
No direct glare to patient's visitor.
No direct glare to adjacent patients. (3 footcandles maximum on wall behind adjacent patient's bed.)

45

110

140

110

45

14

4

2

1

1

1

1

44

83

95

83

44

19

7

3

2

2

1

1

30

45

50

45

30

16

8

4

3

3

2

1

16

20

22

20

16

11

7

4

3

3

2

1

7

9

9

7

4

3

2

2

1

1

3

3

2

2

1

1

1

2

1

1

Reading Light

Eliminates reflected glare from reading material (over shoulder illumination).
No direct glare to patient or visitors. (7 footcandles maximum at head of bed. 15 footcandles maximum at foot of bed.)
Controls light directly onto patient's bed.
No reading light spill-over to adjacent bed (2 foot/candles maximum at head of adjacent patient's bed.)

   

MD*4 2' x 2' Recessed or Surface 

MD2G2SB

Page 2 of 4

Multi-Function Patient Lighting

Illumination at the reading task range 50-60 footcandles

READING LIGHT

ON

ADJACENT

MD*4

OFF

FOOTCANDLES ON BEDS

WALL

3"

6"

BED

BED

12"

3"

6"

12"


2

2

2

2

2

2

1

1

1

1

1

1

3

3

3

3

3

2

2

2

1

1

1

1

6

7

7

7

6

4

3

3

2

2

1

1

33

38

39

38

33

23

16

12

9

5

3

2

30

38

38

38

30

23

15

12

8

6

3

2

14

15

15

15

14

11

9

7

5

4

2

2

5

5

5

5

5

5

4

4

2

2

1

1

AMBIENT LIGHT

ADJACENT

MD*4

ON

OFF

LIGHTED

ZONE

SHIELDED

ZONE

SHIELDED

ZONE

Illumination at the
reading task ranges
50-60 footcandles.

LIGHTED

ZONE

Содержание MD2G2SB

Страница 1: ... Function Patient Lighting Lightolier a Genlyte company www lightolier com Technical Information 978 657 7600 Fax 978 658 0595 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2007 a Genlyte company Section 8 Folio R40 12 Rev B S Surface G exposed T grid ceiling MOUNTING METHODS DIMENSIONS 1 Reading light with ...

Страница 2: ...ors 7 footcandles maximum at head of bed 15 footcandles maximum at foot of bed Controls light directly onto patient s bed No reading light spill over to adjacent bed 2 foot candles maximum at head of adjacent patient s bed MD 4 2 x 2 Recessed or Surface MD2G2SB Page 2 of 4 Multi Function Patient Lighting Illumination at the reading task range 50 60 footcandles READING LIGHT ON ADJACENT MD 4 OFF FO...

Страница 3: ...e with that manufacturers pillow speaker The pil low speaker is used to control the television call the nurse and control the lighting To control the lighting it should be specified to have a normally open contact switch Pressing this switch on the pillow speaker the first time turns the ambient light on pressed a second time turns the reading light on and the ambient light off pressed a third tim...

Страница 4: ...0 Labels I B E W UL and ULc Listed This product may have a mercury containing lamp Manage in accord with Disposal Laws See www lamprecycle org Options Accessories Access Plates Top wiring access plate is shipped with fixture as standard When access plates are required in advance for wiring convenience specify separately Catalog Number ACP Drywall Kit or Plaster Ceiling Order Catalog Number FK92X2 ...

Отзывы: