Mini-Beam 2' x 4' Recessed Fluorescent
MBS2GPW154
Page 2 of 2
Direct/Indirect, Static, 1 Lamp, Linear T5, 54 Watt or 28 Watt
Lightolier
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
Copyright 2003 Lightolier
Section5/Folio M20-20
Job Information
Type:
Ordering Information
Explanation of Catalog Number. Example: MBS2GPW154120PGGLR
Options/Accessories
Fusing:
Internal fast-blow fusing. Suffix:
GLR
.
Internal slow-blow fusing. Suffix:
GMF
.
Electrical/Wiring Options:
Consult factory.
Specifications
Performance:
In an installation of 1 lamp 54W luminaires in a room cavity of 1,
with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less
than .82. To reduce glare the average brightness at 65° shall not exceed 2146
candelas per square meter. To control veiling reflections, luminaire output in the
30°-90° zone shall not be less than 74.9%.
Materials: Housing
is die-formed 20 gauge steel.
Finish: Chassis exterior
–baked white acrylic enamel.
Reflector
–baked flat
white acrylic enamel, minimum 86% reflectance. Phosphate undercoating.
Lamp Shield
–baked flat white acrylic enamel.
Electrical:
Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels:
I.B.E.W./UL and ULc Listed.
Photometry
Model No. MBS2GPW154120PG
MB
Mini-Beam
Direct/Indirect
Recessed
with Perforated
Mesh Shield
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
P
Perforated
Lamp Shield
W
White
Reflector
Voltage:
120 or 277
Options:
Add appropriate
suffix to catalog
no, ie: (GLR)
Ballast:
PI
= Linear T5
Instant Start
Less than 10 THD
PG
= Programmed
Start
Less than 10 THD
DA
= DALI digital
addressable
dimming
coefficients of utilization — zonal cavity method
(effective floor cavity reflectance 0.20)
RF
20
20
20
RC
80
50
30
RW
70
50
30
50
30
10
50
30
10
1
85
82
78
76
74
72
73
71
70
2
77
71
66
67
63
59
64
61
58
3
71
63
56
59
54
50
57
53
49
4
65
55
49
52
47
42
51
46
42
5
59
49
42
46
40
36
45
39
35
6
54
43
36
45
35
31
40
35
31
7
50
39
32
37
31
27
36
31
27
8
46
35
28
33
27
23
32
27
23
9
42
31
25
30
24
20
29
24
20
10
39
28
22
27
21
18
26
21
17
visual comfort probability
(rated lumens per lamp ????.)
room size
ceiling height
ceiling height
W
L
8.5
10.0
13.0
16.0
8.5
10.0
13.0
16.0
20
20
66
73
83
91
59
67
80
90
20
30
61
66
73
82
54
57
66
77
20
40
59
62
68
74
54
55
58
66
20
60
58
61
64
70
53
55
56
60
30
20
65
71
81
89
60
68
78
88
30
30
60
64
70
79
56
58
64
75
30
40
58
60
65
71
54
55
57
64
30
60
57
59
61
66
54
54
54
57
30
80
57
59
60
64
54
55
53
56
40
20
66
71
80
88
63
69
78
87
40
30
61
64
69
77
58
59
65
74
40
40
58
60
63
69
56
56
57
63
40
60
58
58
59
64
55
55
54
56
40
80
58
58
58
61
56
55
53
55
40
100
59
59
58
60
56
56
53
54
60
30
63
65
68
76
60
61
65
74
60
40
60
61
62
68
58
58
57
63
60
60
59
59
58
62
57
56
54
56
60
80
59
58
56
59
57
56
53
54
60
100
60
59
56
58
57
56
53
53
100
40
64
65
64
68
63
62
61
66
100
60
63
62
60
62
61
60
57
58
100
80
62
61
58
59
60
59
55
56
100
100
63
61
57
58
61
59
55
54
room cavity ratio
luminaries lengthwise
luminaries crosswise
LER = FL -56.2
IW - 61.1
BF - 0.88
Comparative yearly lighting energy cost per 1000 lumens = $7.40
06984
LIGHTOLIER, INC.
MBS2GPW154120PG
S
Body Style:
S
= Static
1
Lamp
Quantity
Lamp Quantity:
(By others)
54
= HO/T5 54 Watt
28
= 28 Watt T5
For Local 3 Manufacturing, substitute
for
. Example: MNS2GPW154120PGGLR
.
MN
MN
For Local 3
Manufacturing
MB