background image

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2010 Philips Group • D0410

Job Information 

Type:

Lytespan

®

 Track Lighting System 

83W4

Page 2 of 2 

PowerArc

 Modular T-4 Single Ended Metal Halide Wall Washer

Distance From Ceiling

La mp Information:

70W CDM T4 Single Ended Metal Halide. 
Initial Lumens: 6400 
CRI:  83 
Rated Avg. life:  6,000 - 9,000 hrs.

Lighting Data

   

 

  1' 

150 

125 

56 

18 

4

  2' 

146 

121 

67 

26 

10 

4

  3' 

86 

75 

51 

27 

12 

5

  4' 

54 

47 

36 

23 

12 

5

  5' 

35 

32 

25 

18 

10 

5

  6' 

25 

23 

19 

14 

5

  7' 

18 

17 

14 

11 

5

  8' 

13 

12 

11 

4

  9' 

10 

 

 

 

169  118  169

 

166  138  166

 

111  105  111

 

79  79  79

 

57  56  57

 

46  45  46

 

36  35  36

 

28  28  28

 

23  23  23

 

 

 

 

 

 

Footcandles on Wall

  Track 3 Feet From Wall 

Single Unit 

Multiple  Units

4'

 

 

 

157  39  157

 

150  54  150

 

90  55  90

 

61  49  61

 

40  36  40

 

32  31  32

 

25  25  25

 

19  20  19

 

16  16  16

6'

3'

50°

EXAMPLE:  With track located 4' from wall and multiple units spaced 
6' on center and aimed 50˚ from horizontal, the illumination on wall 4' 
from ceiling will be 58 f.c. beneath units and 51 f.c. between units.

   

 

  1' 

66 

61 

39 

17 

1

  2' 

94 

84 

58 

29 

12 

5

  3' 

72 

66 

49 

30 

15 

7

  4' 

49 

45 

36 

25 

15 

8

  5' 

34 

31 

26 

20 

13 

8

  6' 

24 

23 

19 

16 

11 

7

  7' 

18 

17 

15 

13 

10 

7

  8' 

14 

14 

12 

10 

6

  9' 

11 

11 

10 

5

 

 

 

75  79  75

 

118  120  118

 

104  105  104

 

82  82  82

 

64  63  64

 

50  48  50

 

40  40  41

 

34  34  34

 

29  28  29

 

 

 

68  54  68

 

104  84  104

 

86  80  86

 

66  65  66

 

52  52  52

 

40  39  40

 

33  32  33

 

28  28  28

 

23  23  24

 

 

 

66  34  66

 

98  57  98

 

78  60  78

 

58  51  58

 

44  43  45

 

34  33  34

 

27  27  27

 

24  24  24

 

20  20  20

 

  Track 4 Feet From Wall 

Single Unit 

Multiple  Units

4'

5'

6'

4'

Distance From Ceiling 

Footcandles are average and rounded off and data for multiple units are based on a minimum of five units.

Footcandles on wall:

58 f.c.

51 f.c.

58 f.c.

4'

50

ϒ

6'

4'

   

0' 

1' 

2' 

3' 

4'  5'

   

0' 

1' 

2' 

3' 

4'  5'

Beam Center

Beam Center

 

 

 

160  67  160

 

154  88  154

 

96  77  96

 

66  63  66

 

46  45  46

 

37  37  37

 

29  29  29

 

23  23  23

 

19  19  19

5'

50°

For 20W: Multiply values by .25 

Rated Lamp Life 7,500 - 9,000 Hrs.

For 39W: Multiply values by .50 

Rated Lamp Life 9,000 - 10,000 Hrs.

Отзывы: