Lytecel 6
LIA6GPNXR128 or 228
Page 2 of 2
Recessed Lens Fluorescent, Static or Air Return
6" Width X 48" Length, 1 or 2 Lamp T5
Ordering Information
Explanation of Catalog Number. Example: LIA6GPNXR128UNVPG
Options/Accessories
Access Plate
: Top Wiring access plate is shipped with fixture as standard. When
access plates are required in advance for wiring convenience, specify separately.
Order Catalog Number:
ACP5 CSP
.
Electrical/Wiring Options
: Consult factory.
EM Pack
or
Dimming Ballast
: Consult factory.
Fusing
: Internal fast-blow fusing. Suffix:
A
.
Internal slow-blow fusing. Suffix:
C
.
Chicago Plenum:
Suffix:
C
.
Specifications
Performance:
In an installation of 1 lamp 28W luminaire in a room cavity ratio
of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less
than .77 with a spacing to mounting ratio of 1.1 perpendicular to the lamps.
Air Handling
- Side air slots for air return.
Materials: Chassis parts
are 20 gauge cold rolled steel.
Lytecel
Body Style:
A
=Air Return
S
=Static
6
Fixture
Width 6"
Lens Style:
PN
= .08 White
Acyrlic
VA
= .095 Virgin
Acyrlic
KA
= .156 Virgin
Acyrlic
X
R
Lamp
Quantity:
(By others)
1
=1 Lamp
2
=2 Lamps
28
Lamp Fixture
Length:
28
=T5
(Nominal 48")
UNV
Ballast Type:
<
10THD
1 or 2 Lamp 28w Elec. T5
P
I
†
†
1 or 2 Lamp 28w Elec. T5
PG††
†
†Instant Start (120, 277 or
UNV
)
††Program Rapid Start (
UNV
only)
DA
=DALI digital addressable dimming.
Options:
Add appropriate
suffix to catalog
no, ie: (A)
Voltage:
120, 277 or
UNV
=120-277
0.0
45.0
90.0
FLUX
0
844
844
844
5
831
837
840
80
15
798
791
782
223
25
737
702
675
325
35
652
588
568
376
45
548
474
438
371
55
424
340
292
309
65
286
194
146
201
75
139
66
66
91
85
21
21
18
24
90
3
7
8
Model No. LIA6GPNXR128UNVPG
LER = FP - 62.5 IW - 31.99 BF - 1.00
Comparative yearly lighting energy cost per
1000 lumens = $3.84
Report Number: G2008084
Catalog Number: LIA6GPNXR128UNVPG
Lamp: F28 T5
Luminaire: 6" wide Troffer with PN lens.
Ballast: B228PUNV-C
Report is based on 2750 Lumens per lamp.
Efficiency: 72.7%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.1
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
46.800
4.560
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
5627.
4867.
4497.
55
5367.
4304.
3696.
65
4913.
3333.
2508.
75
3899.
1851.
1851.
85
1749.
1749.
1499.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
1
80 77 74 72 70 68 69 67 66
2
73 67 63 64 60 57 61 58 56
3
67 60 54 56 52 48 55 51 48
4
62 53 47 51 46 42 49 45 41
5
57 48 42 46 40 36 44 40 36
6
53 43 37 41 36 32 40 35 32
7
49 39 33 38 32 29 37 32 28
8
46 36 30 35 29 26 34 29 26
9
43 33 27 32 27 23 31 26 23
10 40 31 25 30 25 21 29 24 21
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
627
22.8
31.4
0
0-
0
40
1004
36.5
50.2
0
0-
0
60
1683
61.2
84.2
0
0-
0
90
2000
72.7
100.0
90-180
000
0
0.0
00
0.0
0
0-180
2000
72.7
100.0
ZONAL LUMEN SUMMARY
Reflector:
R
=Miro aluminum
Reflector
Ceiling Type:
G
= 9/16" or
15/16"Grid
T
= Slot Grid
D
= 9/16" Tegular
Grid
Specifications (continued)
Finish: Reflector:
95% reflective Miro aluminum reflector.
Chassis exterior
—black baked polyester enamel.
Electrical:
Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
Labels:
I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See:
www.lamprecycle.org
Job Information
Type:
-
0.0
45.0
90.0
FLUX
0
1342
1342
1342
5
1322
1331
1337
126
15
1270
1256
1240
354
25
1172
1114
1070
516
35
1038
929
901
596
45
871
751
698
589
55
676
539
455
488
65
458
305
225
317
75
225
100
104
145
85
35
32
30
37
90
4
11
13
Model No. LIA6GPNXR228UNVPG
LER = FP - 56.4 IW - 56.21 BF - 1.00
Comparative yearly lighting energy cost per
1000 lumens = $4.25
Report Number: G2008075
Catalog Number: LIA6GPNXR228UNVPG
Lamp: (2) F28 T5
Luminaire: 6" wide Troffer with PN lens.
Ballast: B228PUNV-C
Report is based on 2750 Lumens per lamp.
Efficiency: 57.6%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.1
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
46.800
4.560
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
8943.
7711.
7167.
55
8557.
6823.
5759.
65
7868.
5240.
3865.
75
2912.
2805.
2917.
85
2916.
2666.
2499.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
1
63 61 58 57 55 54 55 53 52
2
58 53 50 50 48 45 49 46 44
3
53 47 43 45 41 38 43 40 38
4
49 42 37 40 36 33 39 35 33
5
45 38 33 36 32 29 35 31 29
6
42 34 29 33 29 25 32 28 25
7
39 31 26 30 26 23 29 25 22
8
36 29 24 27 23 20 27 23 20
9
34 26 22 25 21 18 25 21 18
10 32 24 20 23 19 17 23 19 17
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
996
18.1
31.4
0
0-
0
40
1593
29.0
50.3
0
0-
0
60
2670
48.5
84.3
0
0-
0
90
3168
57.6
100.0
90-180
000
0
0.0
00
0.0
0
0-180
3168
57.6
100.0
ZONAL LUMEN SUMMARY
Standard Lytecel
For NYC Code – Local 3 Manufactured
LI
LN