background image

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 a Philips Group

Section 1A/Folio E10-10

Lightolier is a Philips group brand

Lytecel 6

LIA6GPNXR128 or 228

Page 2 of 2

Recessed Lens Fluorescent, Static or Air Return

6" Width X 48" Length, 1 or 2 Lamp T5

Ordering Information

Explanation of Catalog Number. Example: LIA6GPNXR128UNVPG

 Options/Accessories

Access Plate

: Top Wiring access plate is shipped with fixture as standard. When

access plates are required in advance for wiring convenience, specify separately.
Order Catalog Number: 

ACP5 CSP

.

Electrical/Wiring Options

: Consult factory.

EM Pack

or 

Dimming Ballast

: Consult factory.

Fusing

: Internal fast-blow fusing. Suffix: 

A

.

Internal slow-blow fusing. Suffix: 

C

.

Chicago Plenum: 

Suffix: 

C

.

Specifications

Performance:

In an installation of 1 lamp 28W luminaire in a room cavity ratio

of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less
than .77 with a spacing to mounting ratio of 1.1 perpendicular to the lamps. 

Air Handling

- Side air slots for air return.

Materials: Chassis parts 

are 20 gauge cold rolled steel.

Lytecel

Body Style:

A

=Air Return

S

=Static

6

Fixture

Width 6"

Lens Style:

PN 

= .08 White

Acyrlic

VA 

= .095 Virgin

Acyrlic

KA 

= .156 Virgin

Acyrlic

X

R

Lamp

Quantity:

(By others)

1

=1 Lamp

2

=2 Lamps

28

Lamp Fixture

Length:

28

=T5

(Nominal 48")

UNV

Ballast Type:

<

10THD

1 or 2 Lamp 28w Elec. T5

P

I

1 or 2 Lamp 28w Elec. T5

PG††

†Instant Start (120, 277 or 

UNV

)

††Program Rapid Start (

UNV

only)

DA

=DALI digital addressable dimming.

Options:

Add appropriate

suffix to catalog

no, ie: (A)

Voltage:

120, 277 or

UNV

=120-277

0.0

45.0

90.0

FLUX

0

844

844

844

5

831

837

840

80

15

798

791

782

223

25

737

702

675

325

35

652

588

568

376

45

548

474

438

371

55

424

340

292

309

65

286

194

146

201

75

139

66

66

91

85

21

21

18

24

90

3

7

8

Model No. LIA6GPNXR128UNVPG

LER = FP - 62.5      IW - 31.99      BF - 1.00
Comparative yearly lighting energy cost per

1000 lumens = $3.84

Report Number: G2008084
Catalog Number: LIA6GPNXR128UNVPG
Lamp: F28 T5
Luminaire: 6" wide Troffer with PN lens.
Ballast: B228PUNV-C
Report is based on 2750 Lumens per lamp.
Efficiency: 72.7%

CIE Type-Direct-Indirect
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.1

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

46.800

4.560

CANDELA DISTRIBUTION

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

5627.

4867.

4497.

55

5367.

4304.

3696.

65

4913.

3333.

2508.

75

3899.

1851.

1851.

85

1749.

1749.

1499.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

1

80 77 74 72 70 68 69 67 66

2

73 67 63 64 60 57 61 58 56

3

67 60 54 56 52 48 55 51 48

4

62 53 47 51 46 42 49 45 41

5

57 48 42 46 40 36 44 40 36

6

53 43 37 41 36 32 40 35 32

7

49 39 33 38 32 29 37 32 28

8

46 36 30 35 29 26 34 29 26

9

43 33 27 32 27 23 31 26 23

10 40 31 25 30 25 21 29 24 21

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

627

22.8

31.4

0

0-

0

40

1004

36.5

50.2

0

0-

0

60

1683

61.2

84.2

0

0-

0

90

2000

72.7

100.0

90-180

000

0

0.0

00

0.0

0

0-180

2000

72.7

100.0

ZONAL LUMEN SUMMARY

Reflector:

R

=Miro aluminum

Reflector

Ceiling Type:

G

= 9/16" or 

15/16"Grid

T

= Slot Grid

D

= 9/16" Tegular

Grid

Specifications (continued)

Finish: Reflector:

95% reflective Miro aluminum reflector. 

Chassis exterior

—black baked polyester enamel.

Electrical: 

Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of

ballast, use wire suitable for at least 90°.

Labels:

I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See:
www.lamprecycle.org

Job Information  

Type:

-

0.0

45.0

90.0

FLUX

0

1342

1342

1342

5

1322

1331

1337

126

15

1270

1256

1240

354

25

1172

1114

1070

516

35

1038

929

901

596

45

871

751

698

589

55

676

539

455

488

65

458

305

225

317

75

225

100

104

145

85

35

32

30

37

90

4

11

13

Model No. LIA6GPNXR228UNVPG

LER = FP - 56.4      IW - 56.21      BF - 1.00
Comparative yearly lighting energy cost per

1000 lumens = $4.25

Report Number: G2008075
Catalog Number: LIA6GPNXR228UNVPG
Lamp: (2) F28 T5
Luminaire: 6" wide Troffer with PN lens.
Ballast: B228PUNV-C
Report is based on 2750 Lumens per lamp.
Efficiency: 57.6%

CIE Type-Direct-Indirect
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.1

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

46.800

4.560

CANDELA DISTRIBUTION

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

8943.

7711.

7167.

55

8557.

6823.

5759.

65

7868.

5240.

3865.

75

2912.

2805.

2917.

85

2916.

2666.

2499.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

1

63 61 58 57 55 54 55 53 52

2

58 53 50 50 48 45 49 46 44

3

53 47 43 45 41 38 43 40 38

4

49 42 37 40 36 33 39 35 33

5

45 38 33 36 32 29 35 31 29

6

42 34 29 33 29 25 32 28 25

7

39 31 26 30 26 23 29 25 22

8

36 29 24 27 23 20 27 23 20

9

34 26 22 25 21 18 25 21 18

10 32 24 20 23 19 17 23 19 17

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

996

18.1

31.4

0

0-

0

40

1593

29.0

50.3

0

0-

0

60

2670

48.5

84.3

0

0-

0

90

3168

57.6

100.0

90-180

000

0

0.0

00

0.0

0

0-180

3168

57.6

100.0

ZONAL LUMEN SUMMARY

Standard Lytecel

For NYC Code – Local 3 Manufactured

LI

LN