background image

Lightolier 

a Genlyte company 

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • C1007

Job Information 

Type:

Lytecaster

®

 Performance Recessed CFL Downlighting 

2001

Page 2 of 2 

3 ¾" Aperture Vertical Open, Compact Fluorescent, Performance Series, Reflector Trim

18W TRIPLE TUBE LAMP

, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM

13W TRIPLE TUBE LAMP

, LUMEN RATING = 900 LMS, ELECTRONIC BALLAST, CL FINISH TRIM

1

56

113

169

225

60˚

30˚

13W QUAD TUBE LAMP

, LUMEN RATING = 900 LMS, ELECTRONIC BALLAST, CL FINISH TRIM

1

50

100

150

200

60˚

30˚

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0 61  61  61  61  60  60  57  57  55  55  52
1 58  56  54  53  55  52  53  50  51  49  47
2 54  51  48  46  50  45  48  44  46  43  41
3 50  46  42  40  45  39  44  39  42  38  37
4 46  41  38  35  41  35  40  34  38  34  32
5 43  38  34  31  37  31  36  30  35  30  29
6 40  34  30  27  34  27  33  27  32  27  26
7 37  31  27  24  31  24  30  24  29  24  23
8 35  29  25  22  28  22  28  22 27  22  21
9 33  26  22  20  26  20  25  20  25  20  19

10 31  24  21  18  24  18  24  18  23  18  17

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 17.0

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30

175.46 

19.5 

37.8

0-40

294.57 

32.7 

63.5

0-60

458.58 

51 

98.8

0-90

464.18 

51.6 

100

90-120

0

90-130

0

90-150

0

90-180

0

 0

 0

0-180

464.18 

51.6 

100

**  Efficiency = 51.6%** 

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

19.02

10-20

60.03

20-30

96.41

30-40

119.11

40-50

113.45

50-60

50.56

60-70

 5.48

70-80

.13

80-90

0

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

CANDLEPOWER SUMMARY

Angle

0˚ CP

190

195

10 

207

15

212

20 

213

25 

209

30 

202

35 

191

40 

175

45 

151

50 

108

55 

53

60 

18

65 

3

70 

1

75

0

80 

0

85 

0

90 

0

SC = 1.5

CERTIFIED TEST REPORT NO. 3040FR
COMPUTED BY LSI PROGRAM 
**TEST-LITE**

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0 53  53  53  53  52  52  50  50  48  48  45
1 50  49  47  46  48  45  46  44  44  43  41
2 47  44  42  40  43  39  42  38  40  38  36
3 44  40  37  35  39  34  38  34  37  33  32
4 40  36  33  30  35  30  34  30  33  29  28
5 37  33  29  27  32  27  31  26  30  26  25
6 35  30  26  24  29  24  29  24  28  23  22
7 32  27  24  21  27  21  26  21  26  21  20
8 30  25  22  19  25  19  24  19  24  19  18
9 28  23  20  17  23  17  22  17  22  17  16

10 27  21  18  16  21  16  21  16  20  16  15

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 16.0

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30

55.05 

17.2 

38.4

0-40

257.28 

28.6 

63.7

0-60

399.05 

44.3 

98.8

0-90

403.78 

44.9 

100

90-120

0

90-130

0

90-150

0

90-180

0

0-180

403.78 

44.9 

100

**  Efficiency = 44.9%** 

CANDLEPOWER SUMMARY

Angle

0˚ CP

174

10 

179

15

183

20 

182

25 

187

30 

187

35 

179

40 

164

45 

146

50 

126

55 

97

60 

48

65 

17

70 

2

75

0

80 

0

85 

0

0

0

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

17.21

10-20

52.09

20-30

85.75

30-40

102.22

40-50

 95.83

50-60

45.94

60-70

4.74

70-80

0

80-90

0

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

SC = 1.4

CERTIFIED TEST REPORT NO. 3039FR
COMPUTED BY LSI PROGRAM 
**TEST-LITE**

1

75

150

225

300

60˚

30˚

SC = 1.5

CERTIFIED TEST REPORT NO. 3038FR
COMPUTED BY LSI PROGRAM 
**TEST-LITE**

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0 56  56  56  56  55  55  53  53  50  50  47
1 53  52  50  49  50  48 49  47  47  45  43
2 50  47  44  42  46  42  44  41  43  40  38
3 46  42  39  37  42  37  40  36  39  35  34
4 43  38  35  32  38  32  37  32  36  31  30
5 40 35  31  29  34  28  33  28  32  28  27
6 37  32  28  25  31  25  30  25  30  25  24
7 35  29  25  23  29  23  28  23  27  22  21
8 32  27  23  21  26  21  26  20  25  20  19
9 30  24  21 19  24  19  24  18  23  18  18

10 28  23  19  17  22  17  22  17  22  17  16

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 22.0

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30

222.19 

18.5 

39

0-40

370.28 

30.9 

65.1

0-60

564.67 

47.1 

99.2

0-90

569.15 

47.4 

100

90-120

0

90-130

0

90-150

0

90-180

0

 0

 0

0-180

569.15 

47.4 

100

**  Efficiency = 47.4%** 

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

23.94

10-20

75.59

20-30

122.65

30-40

148.09

40-50

136.28

50-60

58.12

60-70

4.48

70-80

.0

80-90

0

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

CANDLEPOWER SUMMARY

Angle

0˚ CP

239

246

10 

260

15

266

20 

271

25 

267

30 

255

35 

238

40 

215

45 

180

50 

130

55 

59

60 

19

65 

1

70 

0

75

0

80 

0

85 

0

90 

0

Отзывы: