Lytecaster
®
Recessed Downlighting
1104F18ES
Page 1 of 1 6 3/4" Aperture
0
®
1 Lt 18W Quad/Triple Tube Compact Fluorescent IC Frame-In Kit
Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.
Frame-In Kit
Reflector Trims — See Individual Reflector Trim Specification Sheets
Voltage
Lamp
Open Downlight
Enclosed
Diffusers
Wall
Washer
Cross
Blade
Anodized
Reflector Anodized
Cone
Satin Cone
Baffles
Basic White
1104F18ES
1104F18ESN
120V
18W
Quad or
Triple
Tube
1143
1144
1144CD
1112
1112NM
1113
1113BK
1113BKNM
1113CD
1113CDNM
1113NM
1113WH
1108
1108NM
1110
1110NM
1105
1105BNM
1105NM
1105WH
1176
1176WH
1179M1*
1179WH*
1171
1170M1
1121
1124
1126**
1128**
1134
1177SH
1177LX**
1178SH
1190**
1185
1186
1186WH
1135
1135WH
1132**
Features
1. Housing:
.032” (#20 ga.) UL listed for direct contact with thermal insulation.
Allows installation in ceilings up to 2" thick. Can be removed for access
to junction box, ballast and ceiling plenum. AirSeal
®
housing minimizes
air leakage to less than 2 CFM at 1.57 PSF (or 75pa), which complies with
Model Energy Code (Section 602.3.3) and Washington State Energy Code
(Section 502.4) and reduces heat loss and condensation in ceiling.
2. Mounting Frame:
.048” (#18 ga.) galvanized steel. Locks into position along
length of mounting bars with locking spring and bendable slot. (3) slots 90°
apart simplify alignment.
3. Junction Box:
2" X 4" X 3 1/2" (22 cu. in.) .032" (#22 ga.) galvanized steel.
UL listed for branch circuit wiring supplying connected luminaires. Integral
cable clamps permit attachment of non-metallic (#12 or #14 ga.) Romex
®
cable without tools or additional connectors.
4. Mounting Bars:
.059” (#16 ga.) galvanized steel. Bars pivot for easy
attachment and wire-in below ceiling line. Bars extend to accommodate
16" to 24" O.C. joist spacing. Bars can accommodate 9" O.C. joist spacing
after a slight field modification (see Instruction Sheet). Features integral
self-tapping phillips screws or nails for secure attachment to wood or metal
construction. Attaches to T-bar ceilings without the need of accessories.
5. Socket Housing:
Trim retaining spring secures trim to any height on
housing wall.
6. Socket:
(4 Pin,GX24q-2) base, molded thermo-plastic. Pre-wired with #18
AWG leads to junction box.
7. Ballast:
Electronic 120V, end of life protected, FCC class “B” consumer
limits, class “A” sound rating. Energy Star
®
qualified.
Electrical
Input Watts: 19
*
Recommend Triple Tube Lamp for Optimal Performance.
Amps: .16
**
Use Triple Tube Lamp Only.
Ballast Factor: 1.0
Power Factor: .97
Electrical (cont.)
Max THD %: 10
Min Start Temp: 0˚F/ -18˚C
Options & Accessories
AirSeal
®
Kit: LAS56 (optional)
Note:
Use only if factory installed tape or knockouts are removed from vertical
adjustment slots in housing wall.
Labels
UL (Type IC Suitable for Damp Locations)
Complies with Air Leakage Requirements stated in the Model Energy Code,
California Title 24 and the Washington State Energy Code.
Romex
®
is a registered trademark of General Cable Industries Inc.
13" MIN.
24" MAX.
7"
APERATURE
10 3/4"
OVERALL
LENGTH
7 5/16"
OVERALL
WIDTH
7 1/2"
OVERALL
HEIGHT
1
2
3
4
5
6
7
Ceiling Opening 7" diameter