Lighting Systems

 Silhouette

®

 SA

1BHFPG

-VNJOPVT*OEJSFDU-JHIU5QFS'PPU /PNJOBM4FDUJPO

Mounting & Joiner Block Accessories

CANDLEPOWER

ZONE      0

22

45          67        90

DEG.

CANDELAS

180

607

607

607

607

607

175

606

613

571

629

631

165

592

629

668

710

705

155

557

626

686

689

682

145

492

595

598

537

528

135

399

496

429

448

461

125

313

363

363

437

434

115

206

236

312

339

346

105

113

171

202

216

217

95

23

47

48

54

57

90

6

9

22

38

43

85

5

10

26

43

46

75

4

16

34

51

53

65

7

20

38

52

58

55

17

32

48

63

63

45

20

33

45

58

61

35

30

34

47

57

59

25

35

33

43

50

52

15

39

36

37

40

41

5

42

41

40

39

38

0

40

40

40

40

40

2,000

700

500
400

200

FOOTCANDLE

20

30

50

70 100

1

2

3

4

5

7

10

20

30

40 50

70

100

200

ROOM AREA IN SQUARE FEET

NUMBER OF FIXTURES REQUIRED

300

1,000

100

“X” Block with Suspension

SX36WH (white)
SX36AL (aluminum)

Inline block available (

SI36WH or SI36AL).

“L”Block with Suspension

SL36WH (white)
SL36AL (aluminum)

“T” Block with Suspension

ST36WH (white)
ST36AL (aluminum)

Power Feed End Set

SE36WH (white)
SE36AL (aluminum)

Cable Asse

m

bly

SC36

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

WALL REFLECTANCE

70

50

30

70

50

30

50

30

10

0

80

80

80

69

69

69

50

50

50

1

72

69

65

62

60

57

43

41

40

2

66

60

55

57

52

48

37

35

33

3

60

52

47

51

45

41

33

30

27

4

54

46

40

47

40

35

29

25

23

5

50

41

34

43

35

30

25

22

19

6

45

36

30

39

31

26

23

19

16

7

42

32

26

36

28

23

20

17

14

8

38

29

23

33

25

20

18

15

12

9

36

26

20

31

23

18

17

13

11

10 33

24

18

29

21

16

15

12

9

20% FLOOR CAVITY REFLECTANCE

ROOM CA

VITY RA

TIO

Suspension Length

12"

18"

24"

Footlamberts Above Fixture

223 158

121

Footlamberts Between Fixtures

23.5 25.2 27.9

Ceiling Brightness Ratio

9.9

6.3

4.3

Reflectances of 80% ceiling, 50% walls and 20% floor.
Light loss factor is .85, Room size is 50' x 50',
Run Spacing 10’. Ceiling Height 9’ to 12’. Values are
taken from the center of the room.

Quick Calculator and Ceiling Brightness

1. Find room area on 

vertical axis.

2.  Move across chart to 

footcandle curve.

3. Move down to 

horizontal axis and 
read number of 
fixtures required.

DISTRIBUTION

Zone

Lumens

% Lamp

% Luminaire

0-90

236

8.1

10.0

90-180

2134

73.6

90.0

0-180

2370

81.7

100.0

Calculations are for 28 watt T5 lamps, for 54 watt T5 lamps multiply by 1.7

90˚

85˚

95˚

105˚

75˚

65˚

55˚

115˚

125˚

180˚  175˚      165˚        155˚          145˚               135˚

0˚    5˚        15˚           25˚            35˚                 45˚

750

600

450

300

150

0

90˚

Perfor

m

ance

REPORT NO: 

LRL 299-1J

CAT NO: 

SA14I281WH

LAMPS: 

1 F28T5

LUMENS: 

2900

EFFICIENCY: 

81.7%

CANDLEPOWER CURVE

Sa

m

ple Run

Fixture Lengths & Mounting Locations

4-Foot Joiner

4-Foot Joiner

8-Foot Joiner

5/8” (1.59c

m

)

1-1/4” (3.18c

m

)

Power Feed

End Set

Cable

Asse

m

bly

8-Foot Joiner

8-Foot Joiner

96” (243.84c

m

)

48” (121.92c

m

)

48” (121.92c

m

)

96” (243.84c

m

)

96” (243.84c

m

)

20’ 1/8” (609.92c

m

)

8” (20.32c

m

)

4”
(10.16c

m

)

4” (10.16c

m

)

3.4”

(8.64c

m

)

8”

(20.32c

m

)

4”
(10.16c

m

)

4.6” (11.68c

m

)

4” (10.16c

m

)