background image

Lighting Systems

 

Baselyte-BSL30

Page  of 5   

2 Light T8 Wall Mount Indirect

Job Information 

Type:

 
Job Name: 
Cat. No.: 

 

Lamp(s): 
Notes: 

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Ordering Information

Family

T

 = T8

= Wall Mount

02

EN             

T

8

BSL

02 

= 2 Light

04

 = 4’

08

 = 8’

12

 = 2’

C

 = Custom Color

W

 = Standard

 

  White

Distribution

Lamp Type

No. of Lamps

Housing

Module Length

Wiring 

Voltage

Ballast

Finish

Weight = 3.0 lb./ft

EN

 = Solid

1

 = 20V

2

 = 277V 

= Standard  

<20% THD

= Standard  

<20% THD  
w/fusing

= <0% THD,  

Instant Start

= <0% THD,  

Instant Start  
w/fusing

= <0% THD,  

Program Start

= <0% THD,  

Program Start  
w/fusing    

1

 = cct.

2

 = 2cct. 

= cct. w/EC/NL

= 2cct. w/EC/NL

5

 = cct. w/EM Battery

6

 = 2cct. w/EM Battery

7

 = cct. w/Dimming

= cct. w/cct.  

Thru wire

9

 = 2cct. w/cct.  

Thru wire

Note:

 Please consult 

wiring section of spec
sheets for more
wiring options.

Specifications

Features

.  Housing: die-formed 20ga. cold rolled steel
2.  End Set: die-cast metal with baked powder coat finish
3.  Lamping: two T8 lamps
4.  Configuration: 4’, 8’ and 2’ module lengths or continuous rows
5.  Ballasts: electronic 20V or 277V

Finish

High-quality white powder coat with textured matte finish.
Custom colors available. Consult factory.

Mounting

Flexible mounting locations.

Electrical

All luminaires are factory pre-wired to module ends with quick-wire 
connectors.

Joints & Intersections

Self-aligning joining system with hands-free pre-joining wire access.

Labels

UL, CSA standards.

Individual Fixtures

.  Determine the number of individual modules required
2.  Order one end set per module
3.  Order one non-power mount per module
4.  Order one power mount per module

Continuous Rows*

.  Determine run length
2.  Order the appropriate number and length of modules for complete run 
3.  Order one end set for each run
4.  Order one non-power mount for each module
5.  Order one power mount per run
6.  Order one joiner per module minus one (e.g. 3 modules requires 2 joiners)

*Note

: Some runs may require additional power mounts. Please see the  

‘Run Configuration’ table on the next page for more details.