Lighting Systems
Baselyte-BSL25
Page 2 of 7
Light T5 HO Indirect
Lightolier
a Genlyte Company
www.lightolier.com
63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.
Job Information
Type:
Performance
Candlepower Curve
Candlepower Summary
Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW
= suspended standard white
End Set
BSLJS
= suspended joiner
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
2’
Module
Joiner
End Set
Mount
Power
Mount*
4’ run
8’ run
2’ run
6’ run
2
2
20’ run
2
24’ run
2
2
28’ run
2
2
3
32’ run
2
2
3
Report No:
20709
Lamps:
F54T5
Lumens per Lamp:
4650
Efficiency:
94.9%
Up:
00.0%
Down:
0.0%
Zonal Lumen Summary
ZONE
LUMENS %BARE LAMP %LUMINAIRE
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
CANDLEPOWER SUMMARY
ZONE
CANDLEPOWER
DEG.
0
22.5
45
67.5
90
180 1078 1078 1078 1078 1078
175 1073 1073 1077 1080 1081
165 1035 1042 1064 1079 1086
155
963
980 1032 1073 1090
145
860
892
985 1057 1083
135
721
786
925 1031 1070
125
564
667
857
998 1051
115
385
546
792
946 1001
105
197
435
647
691
754
95
35
165
156
80
109
90
2
3
7
3
7
85
0
0
0
0
0
75
0
0
0
0
0
65
0
0
0
0
0
55
0
0
0
0
0
45
0
0
0
0
0
35
0
0
0
0
0
25
0
0
0
0
0
15
0
0
0
0
0
5
0
0
0
0
0
0
0
0
0
0
0
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
90
90
90
77
77
77
52
52
52
1
78
74
71
66
64
61
45
44
42
2
68
62
58
58
54
50
40
37
35
3
59
53
48
51
46
42
35
32
29
4
52
45
40
45
39
35
31
27
24
5
46
39
34
40
34
29
27
23
21
6
41
34
29
35
29
25
24
20
18
7
37
30
25
31
26
22
22
18
15
8
33
26
22
28
23
19
19
16
13
9
30
23
19
26
20
16
18
14
11
10 27
21
17
23
18
14
16
12
10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
4413
4413
0
0
100.0
100.0
0
94.9
94.9
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
90
90
90
77
77
77
52
52
52
1
78
74
71
66
64
61
45
44
42
2
68
62
58
58
54
50
40
37
35
3
59
53
48
51
46
42
35
32
29
4
52
45
40
45
39
35
31
27
24
5
46
39
34
40
34
29
27
23
21
6
41
34
29
35
29
25
24
20
18
7
37
30
25
31
26
22
22
18
15
8
33
26
22
28
23
19
19
16
13
9
30
23
19
26
20
16
18
14
11
10 27
21
17
23
18
14
16
12
10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
4413
4413
0
0
100.0
100.0
0
94.9
94.9
Note
: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note
: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.