Lighting Systems
Baselyte-BSL16
Page 2 of 8
3 Light T5 HO Semi-Indirect
Lightolier
a Genlyte Company
www.lightolier.com
63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.
Job Information
Type:
Performance
Candlepower Curve
Candlepower Summary
Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW
= suspended standard white
End Set
BSLJS
= suspended joiner
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
2’
Module
Joiner
End Set
Mount
Power
Mount*
4’ run
8’ run
2’ run
6’ run
2
2
20’ run
2
24’ run
2
2
28’ run
2
2
3
32’ run
2
2
3
Report No:
990059
Lamps:
F54T5
Lumens per Lamp:
4650
Efficiency:
84.9%
Up:
96.%
Down:
3.9%
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Zonal Lumen Summary
ZONE
LUMENS %BARE LAMP %LUMINAIRE
Candlepower Summary
ZONE
CANDLEPOWER
DEG.
0
22.5
45
67.5
90
180
3199
3199
3199
3199
3199
175
3184
3183
3190
3201
3204
165
3072
3089
3135
3155
3165
155
2858
2901
2961
3016
3042
145
2551
2605
2731
2843
2889
135
2165
2236
2450
2663
2747
125
1714
1818
2174
2470
2571
115
1214
1390
1865
2056
2128
105
657
975
1266
1342
1404
95
154
302
387
341
367
90
5
13
30
46
55
85
11
16
31
49
56
75
19
25
47
67
75
65
26
40
65
84
92
55
41
58
81
99
107
45
64
75
94
111
118
35
88
92
109
119
125
25
109
110
120
127
131
15
123
123
126
131
133
5
131
131
131
131
131
0
132
132
132
132
132
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
81
81
81
70
70
70
49
49
49
1
70
67
64
60
58
56
42
41
39
2
61
56
52
53
49
45
37
34
32
3
54
48
43
46
41
38
32
29
27
4
47
41
36
41
36
32
28
25
23
5
42
35
31
36
31
27
25
22
19
6
37
31
26
32
27
23
22
19
16
7
33
27
22
29
23
20
20
17
14
8
30
24
19
26
21
17
18
15
12
9
27
21
17
23
18
15
16
13
11
10 24
19
15
21
16
13
15
12
9
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
11841
11380
461
3.9
96.1
100.0
3.3
81.6
84.9
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
81
81
81
70
70
70
49
49
49
1
70
67
64
60
58
56
42
41
39
2
61
56
52
53
49
45
37
34
32
3
54
48
43
46
41
38
32
29
27
4
47
41
36
41
36
32
28
25
23
5
42
35
31
36
31
27
25
22
19
6
37
31
26
32
27
23
22
19
16
7
33
27
22
29
23
20
20
17
14
8
30
24
19
26
21
17
18
15
12
9
27
21
17
23
18
15
16
13
11
10 24
19
15
21
16
13
15
12
9
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
11841
11380
461
3.9
96.1
100.0
3.3
81.6
84.9
Note
: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note
: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.