Lighting Systems
Baselyte-BSL15
Page 2 of 8
2 Light T5 HO Semi-Indirect
Lightolier
a Genlyte Company
www.lightolier.com
63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.
Job Information
Type:
Performance
Candlepower Curve
Candlepower Summary
Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW
= suspended standard white
End Set
BSLJS
= suspended joiner
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
2’
Module
Joiner
End Set
Mount
Power
Mount*
4’ run
8’ run
2’ run
6’ run
2
2
20’ run
2
24’ run
2
2
28’ run
2
2
3
32’ run
2
2
3
Report No:
990060
Lamps:
F54T5
Lumens per Lamp:
4650
Efficiency:
80.8%
Up:
94.7%
Down:
5.3%
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Zonal Lumen Summary
ZONE
LUMENS %BARE LAMP %LUMINAIRE
Candlepower Summary
ZONE
CANDLEPOWER
DEG.
0
22.5
45
67.5
90
180
2038
2038
2038
2038
2038
175
2026
2027
2031
2036
2039
165
1952
1964
1977
1988
1994
155
1813
1832
1862
1887
1899
145
1613
1641
1697
1749
1771
135
1367
1403
1496
1611
1660
125
1077
1125
1307
1494
1556
115
751
837
1126
1263
1300
105
398
591
816
878
906
95
74
217
341
316
330
90
3
11
25
40
49
85
7
12
27
43
49
75
14
20
40
59
66
65
21
33
55
73
81
55
35
49
70
86
94
45
56
65
82
96
103
35
78
82
95
105
110
25
97
98
105
111
115
15
110
111
113
116
118
5
118
118
118
118
118
0
119
119
119
119
119
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
78
78
78
67
67
67
47
47
47
1
67
64
62
58
56
53
41
39
38
2
59
54
50
50
47
44
35
33
31
3
51
46
41
44
40
36
31
28
26
4
45
39
35
39
34
30
27
24
22
5
40
34
29
34
29
26
24
21
18
6
35
29
25
31
26
22
22
18
16
7
32
26
21
27
22
19
19
16
14
8
28
23
19
25
20
16
17
14
12
9
26
20
16
22
18
14
16
13
10
10 23
18
14
20
16
13
14
11
9
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
7516
7118.5
397.5
5.3
94.7
100.0
4.3
76.5
80.8
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
78
78
78
67
67
67
47
47
47
1
67
64
62
58
56
53
41
39
38
2
59
54
50
50
47
44
35
33
31
3
51
46
41
44
40
36
31
28
26
4
45
39
35
39
34
30
27
24
22
5
40
34
29
34
29
26
24
21
18
6
35
29
25
31
26
22
22
18
16
7
32
26
21
27
22
19
19
16
14
8
28
23
19
25
20
16
17
14
12
9
26
20
16
22
18
14
16
13
10
10 23
18
14
20
16
13
14
11
9
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
7516
7118.5
397.5
5.3
94.7
100.0
4.3
76.5
80.8
*Note
: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.
Note
: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).