Lightolier H9S2GLR254 Скачать руководство пользователя страница 2

HP90 Recessed Fluorescent

H9S2GLR254 or 154

Page 2 of 2

Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens

Static, 1 or 2 Lamp T5

Ordering Information

Explanation of Catalog Number. Example: H9S2GLR254UNVPG

Options/Accessories

Fusing:

Internal fast blow fusing: SUFFIX:

A

.

Internal slow blow fusing: SUFFIX:

C

.

Drywall Kit:

Order Catalog Number:

FK92X4

.

Electrical Wiring Options:

Consult factory.

For motion or light sensor:

See Folio OA20-10.

Specifications

Performance:

In an installation of 2 lamp 54W luminaires in a room cavity ratio of 1,

with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .88.
To reduce glare the average brightness at 65° shall not exceed 3776 candelas per
square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall
not be less than 74.1%.

Materials: Chassis parts

are die-formed code gauge steel.

Lamp Shield:

Linear prismatic translucent DR acrylic lens.

Specifications (continued)

Finish: Chassis exterior

– baked white acrylic enamel.

Cavity

– baked flat white

acrylic enamel. Rust preventative undercoating.

Reflector

– low iridescence specular

aluminum 95% reflectance.

Electrical:

Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is

within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.

Labels:

I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal
Laws. See: www.lamprecycle.org

Options:

Add appropriate suffix

to catalog no., ie: (A)

HP90

Direct/Indirect

Recessed

S

Body Style:

S

= Static

2

Fixture

Width

G

Ceiling Type:

Fits both

Standard Grid

and

Slot Grid

L

Acrylic Lens

54

Lamp:

(By Others)

54

=T5 54W

(Nominal 48")

R

Reflector:

Specular

Aluminum

Lamp

Quantity

1

=1 Lamp

2

=2 Lamp

Ballast Type:

<

10THD

1 Lamp Elec. T5 HO

PG ††

(54 Watt)

2 Lamp Elec. T5 HO

PG ††

(54 Watt)

††Program Rapid Start (

UNV

only)

0.0

45.0

90.0

FLUX

0

1234

1235

1235

5

1226

1231

1237

117

15

1179

1208

1233

342

25

1088

1151

1202

530

35

957

1051

1121

655

45

791

913

998

698

55

601

750

852

661

65

402

576

713

564

75

207

402

474

384

85

49

68

44

85

90

0

0

0

Model No. H9S2GLR154UNVPG

LER = FP - 66.5

IW - 61.9

BF - 1.02

Comparative yearly lighting energy cost per

1000 lumens = $3.61

Report Number: G2010216

Catalog Number: H9S2GLR154UNVPG

Lamps: F54 T5 HO

Luminaire: HP90 2' x 4' with linear

prismatic lens.

Ballast: Advance ICN-2S54

Report is based on 4500 Lumens per lamp.
Efficiency: 89.7%
CIE Type-Direct-Indirect

Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.4

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

46.920

22.920

CANDELA DISTRIBUTION

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG. 90-DEG.

45

1612.

1860.

2034.

55

1510.

1884.

2140.

65

1371.

1964.

2431.

75

1152.

2238.

2639.

85

810.

1124.

727.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE

FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

0

1 92 92 88 86 83 80 83 80 78

0

2 87 80 73 75 69 65 72 67 64

0

3 79 69 62 65 59 54 63 57 53

0

4 72 61 53 57 51 45 55 49 45

0

5 66 54 46 51 44 39 49 43 38

0

6 61 49 40 46 39 34 45 38 34

0

7 57 44 36 42 35 30 41 34 30

0

8 53 40 33 38 31 27 37 31 26

0

9 49 37 29 35 28 24 34 28 24

10 46 34 27 32 26 22 32 26 21

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

989

22.0

24.5

0

0-

0

40

1644

36.5

40.7

0

0-

0

60

3002

66.7

74.4

0

0-

0

90

4036

89.7

100.0

90-180

000

0

0.0

00

0.0

0

0-180

4036

89.7

100.0

ZONAL LUMEN SUMMARY

Model No. H9S2GLR254UNVPG

LER = FP - 66.5

IW - 112.39

BF - 1.0

Comparative yearly lighting energy cost per

1000 lumens = $3.61

Report Number: G2006118

Catalog Number: H9S2GLR254UNVPG

Lamps: F54 T5 HO

Luminaire: HP90 2' x 4' with linear

prismatic lens.

Ballast: B254UNV-E

Report is based on 4400 Lumens per lamp.
Efficiency: 84.6%
CIE Type-Direct-Indirect

Plane:

0-Deg

90-Deg

Spacing Criteria:

1.3

1.4

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

46.800

22.800

0.0

45.0

90.0

FLUX

0

2340

2340

2340

5

2320

2339

2354

223

15

2228

2326

2406

658

25

2079

2280

2417

1044

35

1851

2134

2220

1303

45

1548

1790

1827

1348

55

1173

1345

1428

1197

65

771

963

1099

950

75

383

625

665

597

85

75

95

60

125

90

0

0

0

CANDELA DISTRIBUTION

0

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG. 90-DEG.

45

3179.

3676.

3752.

55

2970.

3405.

3615.

65

2649.

3309.

3776.

75

2149.

3507.

3731.

85

1250.

1583.

1000.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE

FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

0

1 92 88 84 82 79 77 79 77 74

0

2 83 76 70 71 67 63 69 65 61

0

3 76 67 59 63 57 52 60 56 51

0

4 69 59 51 56 49 44 54 48 44

0

5 64 52 45 50 43 38 48 42 38

0

6 59 47 39 45 38 33 43 37 33

0

7 54 43 35 41 34 29 39 34 29

0

8 50 39 32 37 31 26 36 30 26

0

9 47 36 29 34 28 24 33 27 23

10 44 33 26 31 25 21 31 25 21

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

1926

21.9

25.9

0

0-

0

40

3229

36.7

43.4

0

0-

0

60

5774

65.6

77.5

0

0-

0

90

7446

84.6

100.0

90-180

000

0

0

0.0

00

0.0

0

0-180

7446

84.6

100.0

ZONAL LUMEN SUMMARY

Voltage:

120, 277 or

UNV

=120-277

H9

Standard HP90

HY

For NYC Code – I.B.E.W. Manufactured

Job Information

Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

12/10

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group

Section 5/Folio M32-11 Rev. A