HP90 Recessed Fluorescent
H9S2GLR254 or 154
Page 2 of 2
Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T5
Ordering Information
Explanation of Catalog Number. Example: H9S2GLR254UNVPG
Options/Accessories
Fusing:
Internal fast blow fusing: SUFFIX:
A
.
Internal slow blow fusing: SUFFIX:
C
.
Drywall Kit:
Order Catalog Number:
FK92X4
.
Electrical Wiring Options:
Consult factory.
For motion or light sensor:
See Folio OA20-10.
Specifications
Performance:
In an installation of 2 lamp 54W luminaires in a room cavity ratio of 1,
with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .88.
To reduce glare the average brightness at 65° shall not exceed 3776 candelas per
square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall
not be less than 74.1%.
Materials: Chassis parts
are die-formed code gauge steel.
Lamp Shield:
Linear prismatic translucent DR acrylic lens.
Specifications (continued)
Finish: Chassis exterior
– baked white acrylic enamel.
Cavity
– baked flat white
acrylic enamel. Rust preventative undercoating.
Reflector
– low iridescence specular
aluminum 95% reflectance.
Electrical:
Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is
within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels:
I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal
Laws. See: www.lamprecycle.org
Options:
Add appropriate suffix
to catalog no., ie: (A)
HP90
Direct/Indirect
Recessed
S
Body Style:
S
= Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
54
Lamp:
(By Others)
54
=T5 54W
(Nominal 48")
R
Reflector:
Specular
Aluminum
Lamp
Quantity
1
=1 Lamp
2
=2 Lamp
Ballast Type:
<
10THD
1 Lamp Elec. T5 HO
PG ††
(54 Watt)
2 Lamp Elec. T5 HO
PG ††
(54 Watt)
††Program Rapid Start (
UNV
only)
0.0
45.0
90.0
FLUX
0
1234
1235
1235
5
1226
1231
1237
117
15
1179
1208
1233
342
25
1088
1151
1202
530
35
957
1051
1121
655
45
791
913
998
698
55
601
750
852
661
65
402
576
713
564
75
207
402
474
384
85
49
68
44
85
90
0
0
0
Model No. H9S2GLR154UNVPG
LER = FP - 66.5
IW - 61.9
BF - 1.02
Comparative yearly lighting energy cost per
1000 lumens = $3.61
Report Number: G2010216
Catalog Number: H9S2GLR154UNVPG
Lamps: F54 T5 HO
Luminaire: HP90 2' x 4' with linear
prismatic lens.
Ballast: Advance ICN-2S54
Report is based on 4500 Lumens per lamp.
Efficiency: 89.7%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.4
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
46.920
22.920
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG. 90-DEG.
45
1612.
1860.
2034.
55
1510.
1884.
2140.
65
1371.
1964.
2431.
75
1152.
2238.
2639.
85
810.
1124.
727.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 92 92 88 86 83 80 83 80 78
0
2 87 80 73 75 69 65 72 67 64
0
3 79 69 62 65 59 54 63 57 53
0
4 72 61 53 57 51 45 55 49 45
0
5 66 54 46 51 44 39 49 43 38
0
6 61 49 40 46 39 34 45 38 34
0
7 57 44 36 42 35 30 41 34 30
0
8 53 40 33 38 31 27 37 31 26
0
9 49 37 29 35 28 24 34 28 24
10 46 34 27 32 26 22 32 26 21
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
989
22.0
24.5
0
0-
0
40
1644
36.5
40.7
0
0-
0
60
3002
66.7
74.4
0
0-
0
90
4036
89.7
100.0
90-180
000
0
0.0
00
0.0
0
0-180
4036
89.7
100.0
ZONAL LUMEN SUMMARY
Model No. H9S2GLR254UNVPG
LER = FP - 66.5
IW - 112.39
BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $3.61
Report Number: G2006118
Catalog Number: H9S2GLR254UNVPG
Lamps: F54 T5 HO
Luminaire: HP90 2' x 4' with linear
prismatic lens.
Ballast: B254UNV-E
Report is based on 4400 Lumens per lamp.
Efficiency: 84.6%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.3
1.4
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
46.800
22.800
0.0
45.0
90.0
FLUX
0
2340
2340
2340
5
2320
2339
2354
223
15
2228
2326
2406
658
25
2079
2280
2417
1044
35
1851
2134
2220
1303
45
1548
1790
1827
1348
55
1173
1345
1428
1197
65
771
963
1099
950
75
383
625
665
597
85
75
95
60
125
90
0
0
0
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG. 90-DEG.
45
3179.
3676.
3752.
55
2970.
3405.
3615.
65
2649.
3309.
3776.
75
2149.
3507.
3731.
85
1250.
1583.
1000.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 92 88 84 82 79 77 79 77 74
0
2 83 76 70 71 67 63 69 65 61
0
3 76 67 59 63 57 52 60 56 51
0
4 69 59 51 56 49 44 54 48 44
0
5 64 52 45 50 43 38 48 42 38
0
6 59 47 39 45 38 33 43 37 33
0
7 54 43 35 41 34 29 39 34 29
0
8 50 39 32 37 31 26 36 30 26
0
9 47 36 29 34 28 24 33 27 23
10 44 33 26 31 25 21 31 25 21
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
1926
21.9
25.9
0
0-
0
40
3229
36.7
43.4
0
0-
0
60
5774
65.6
77.5
0
0-
0
90
7446
84.6
100.0
90-180
000
0
0
0.0
00
0.0
0
0-180
7446
84.6
100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV
=120-277
H9
Standard HP90
HY
For NYC Code – I.B.E.W. Manufactured
Job Information
Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
12/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
Section 5/Folio M32-11 Rev. A