HP90 Recessed Fluorescent
H9S1GLR228 or 128
Page 2 of 2
Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T5
Ordering Information
Explanation of Catalog Number. Example: H9S1GLR228UNVPG
Options/Accessories
Fusing:
Internal fast blow fusing: SUFFIX:
A
.
Internal slow blow fusing: SUFFIX:
C
.
Drywall Kit:
Order Catalog Number:
FK91X4
.
Electrical Wiring Options:
Consult factory.
For motion or light sensor:
See Folio OA20-10.
Specifications
Performance:
In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1,
with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .93. To
reduce glare the average brightness at 65° shall not exceed 3851 candelas per square
meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be
less than 72.1%.
Materials: Chassis parts
are die-formed code gauge steel.
Lamp Shield:
Linear prismatic translucent DR acrylic lens.
Finish: Chassis exterior
– baked white acrylic enamel.
Specifications (continued)
Cavity
– baked flat white acrylic enamel. Rust preventative undercoating.
Reflector
–
low iridescence specular aluminum 95% reflectance.
Electrical:
Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is
within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels:
I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal
Laws. See: www.lamprecycle.org
Options:
Add appropriate suffix
to catalog no., ie: (A)
HP90
Direct/Indirect
Recessed
S
Body Style:
S
= Static
1
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
28
Lamp:
(By Others)
28
=T5 28W
(Nominal 48")
R
Reflector:
Specular
Aluminum
Lamp
Quantity
1
=1 Lamp
2
=2 Lamp
Ballast Type:
<
10THD
1 or 2 Lamp Elec. T5
PG †
†
(28 Watt)
1 or 2 Lamp Elec. T5
PG ††
(28 Watt)
2-Lamp Elec. T5
VY
**
(28 Watt)
.95/.35 Bilevel
Step Ballast
†
†Instant Start (120, 277 or UNV)
††Program Rapid Start (
UNV
only)
**.35 20THD
**
.95 10THD
0.0
45.0
90.0
FLUX
0
1661
1661
1661
5
1643
1659
1678
158
15
1581
1654
1725
468
25
1466
1621
1692
737
35
1303
1470
1512
902
45
1088
1217
1236
922
55
823
913
889
793
65
537
590
558
569
75
256
283
250
291
85
38
42
38
50
90
3
4
3
Model No. H9S1GLR128UNVPG
LER = FP - 72.1
IW - 32.6
BF - 1.04
Comparative yearly lighting energy cost per
1000 lumens = $3.33
Report Number: G2010229
Catalog Number: H9S1GLR128UNVPG
Lamps: F28T5
Luminaire: HP90 1' x 4' with linear
prismatic lens.
Ballast: ICN-2S28
Report is based on 2600 Lumens per lamp.
Efficiency: 86.9%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.4
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
47.040
11.040
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG. 90-DEG.
45
4245.
4748.
4822.
55
3958.
4391.
4276.
65
3505.
3851.
3542.
75
2729.
3046.
2665.
85
1203.
1329.
1203.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 97 93 89 87 85 82 84 82 80
0
2 89 81 75 77 72 68 74 70 67
0
3 81 72 64 68 62 57 65 60 56
0
4 74 63 56 60 54 49 58 53 48
0
5 68 57 49 54 47 42 52 46 42
0
6 63 51 43 49 42 37 47 41 37
0
7 58 46 38 44 37 33 43 37 32
0
8 54 42 35 40 34 29 39 33 29
0
9 51 39 31 37 31 26 36 30 26
10 47 36 29 34 28 24 33 28 24
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
1364
24.8
27.9
0
0-
0
40
2266
41.2
46.3
0
0-
0
60
3981
72.4
81.4
0
0-
0
90
4891
88.9
100.0
90-180
000
0
0.0
00
0.0
0
0-180
4891
88.9
100.0
ZONAL LUMEN SUMMARY
Model No. H9S1GLR228UNVPG
LER = FP - 77.2
IW - 63.31
BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $3.11
Report Number: G2006140
Catalog Number: H9S1GLR228UNVPG
Lamps: F28T5
Luminaire: HP90 1' x 4' with linear
prismatic lens.
Ballast: QTP2X28T5/UNV
Report is based on 2750 Lumens per lamp.
Efficiency: 88.9%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.4
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
47.040
11.040
Voltage:
120, 277 or
UNV
=120-277
H9
Standard HP90
HY
For NYC Code – I.B.E.W. Manufactured
0.0
45.0
90.0
FLUX
0
717
717
717
5
709
716
721
68
15
683
702
721
199
25
630
671
707
309
35
554
617
667
385
45
459
541
599
413
55
350
450
490
387
65
236
323
322
297
75
124
164
140
160
85
30
36
36
41
90
0
0
0
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG. 90-DEG.
45
1963.
2314.
2562.
55
1845.
2373.
2583.
65
1689.
2311.
2304.
75
1449.
1916.
1636.
85
1041.
1249.
1249.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 94 90 86 84 82 79 81 79 77
0
2 86 78 72 73 69 65 71 67 63
0
3 78 68 61 64 59 54 62 57 53
0
4 71 60 53 57 51 46 55 49 45
0
5 65 54 46 51 44 39 49 43 39
0
6 60 48 40 46 39 34 44 38 34
0
7 56 44 36 42 35 30 40 34 30
0
8 52 40 32 38 31 27 37 31 27
0
9 48 36 29 35 28 24 34 28 24
10 45 33 27 32 26 22 31 26 22
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
576
22.2
25.5
0
0-
0
40
961
37.0
42.5
0
0-
0
60
1761
67.7
77.9
0
0-
0
90
2260
86.9
100.0
90-180
000
0
0.0
00
0.0
0
0-180
2260
86.9
100.0
ZONAL LUMEN SUMMARY
Job Information
Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
12/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
Section 5/Folio M32-20 Rev. A