Compact Fluorescent

 200

 400

30°

60°

90°

 100

 300

8091CL-D6AO1

Calculite 6" Vetro Downlight, Cat.# 8091CL/D6A01 Opal Lens

32W Sylvania Dulux T/E Triple Tube. Lumen Rating = 2400 LMS.

Universal Ballast #C2642UNVBES(#1)

Candlepower Summary

Angle Along

22.5

45

67.5

Across

LMS

0

460

460

460

460

460

5

447

447

448

449

448

43

10

425

425

426

428

428

15

393

394

396

398

398

112

20

356

357

360

363

364

25

316

317

320

325

327

148

30

274

275

278

284

288

35

231

232

237

245

251

150

40

188

189

194

204

207

45

148

149

152

158

160

119

50

111

111

111

112

113

55

50

50

51

53

54

58

60

42

42

43

44

44

65

36

37

37

37

38

37

70

32

32

32

33

33

75

28

28

28

28

28

30

80

25

25

25

25

25

85

23

23

23

23

23

25

90

20

20

20

21

20

Zonal Lumens and Percentages

Zone

Lumens

% Lamp

%Luminaire

0-30

302

12.61

41.97

0-40

452

18.84

62.73

0-60

629

26.21

87.25

0-90

721

30.04

100.00

40-90

268

11.20

37.27

60-90

91

3.83

12.75

90-180

0

.00

.00

0-180

721

30.04

100.00

**  Efficiency = 30.0%  **

Certified test report no. 3517FR   

Computed by LSI program **TEST-LITE**

SC = 1.0 

Prepared For:

Lightolier

 Fall River, MA

 

Coefficients of Utilization

 

Ceiling

80%

70%

50%

30%

10%

Wall

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Ro

om C

av

ity R

at

io

0 .36 .36 .36 .36 .35 .35 .35 .35 .33 .33 .33 .32 .32 .32 .31 .31 .31 .30
1 .33 .32 .31 .30 .33 .32 .31 .30 .30 .29 .29 .29 .28 .28 .28 .28 .27 .26
2 .31 .29 .28 .26 .30 .29 .27 .26 .28 .26 .25 .27 .26 .25 .26 .25 .24 .24
3 .29 .27 .25 .23 .28 .26 .24 .23 .25 .24 .23 .25 .23 .22 .24 .23 .22 .21
4 .27 .25 .22 .21 .27 .24 .22 .21 .23 .22 .20 .23 .21 .20 .22 .21 .20 .19
5 .26 .23 .20 .19 .25 .22 .20 .19 .22 .20 .18 .21 .20 .18 .21 .19 .18 .18
6 .24 .21 .19 .17 .23 .20 .18 .17 .20 .18 .17 .20 .18 .17 .19 .18 .17 .16
7 .22 .19 .17 .15 .22 .19 .17 .15 .18 .16 .15 .18 .16 .15 .18 .16 .15 .14
8 .21 .18 .15 .14 .21 .17 .15 .14 .17 .15 .14 .17 .15 .14 .16 .15 .14 .13
9 .20 .16 .14 .13 .19 .16 .14 .13 .16 .14 .13 .15 .14 .12 .15 .14 .12 .12

10 .18 .15 .13 .11 .18 .15 .13 .11 .15 .13 .11 .14 .13 .11 .14 .12 .11 .11

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts =  38.0

Tested According to IES Procedures. Test Distance Exceeds Five  

Times the Greatest Luminous Opening of Luminaire.

 150

 300

30°

60°

90°

 75

 225

8011CL-D4AO1

Calculite 4” Vetro Downlight, Cat.# 8011Cl D4A01

18W G.E. Biax T/E triple Tube. Lumen Rating = 1200 LMS.

Universal Ballast #C218UNVBES

Candlepower summary

Angle

Mean CP

Lumens

0

244

5

239

23

10

254

15

263

73

20

255

25

233

107

30

204

35

174

107

40

131

45

56

51

50

21

55

17

16

60

15

65

13

13

70

12

75

10

11

80

9

85

9

10

90

8

SC(Along) = 1.3, SC(Across) = 1.5 

Certified test report no. 3557FR     

Computed by LSI program **TEST-LITE** 

SC = 1.2 

Prepared For:

Lightolier

 Fall River, MA

 

Zonal Lumens and Percentages

Zone

Lumens

% Lamp

%Luminaire

0-30

203

16.97

49.50

0-40

311

25.92

75.59

0-60

377

31.49

91.85

0-90

411

34.29

100.00

40-90

100

8.37

24.41

60-90

33

2.79

8.15

90-180

0

.00

.00

0-180

411

34.29

100.00

**  Efficiency = 34.3%  **

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

10%

Wall

70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

Ro

om C

av

ity R

at

io

0 .41 .41 .41 .41 .40 .40 .40 .40 .38 .38 .38 .36 .36 .36 .35 .35 .35 .34
1 .39 .37 .36 .35 .38 .37 .36 .35 .35 .34 .34 .34 .33 .33 .33 .32 .32 .31
2 .36 .34 .33 .32 .36 .34 .32 .31 .33 .32 .30 .32 .31 .30 .31 .30 .29 .29
3 .34 .32 .30 .28 .34 .31 .30 .28 .30 .29 .28 .30 .28 .27 .29 .28 .27 .26
4 .32 .30 .27 .26 .32 .29 .27 .26 .28 .27 .25 .28 .26 .25 .27 .26 .25 .24
5 .31 .27 .25 .24 .30 .27 .25 .23 .26 .25 .23 .26 .24 .23 .25 .24 .23 .22
6 .29 .26 .23 .22 .28 .25 .23 .22 .25 .23 .21 .24 .23 .21 .24 .22 .21 .21
7 .27 .24 .21 .20 .27 .23 .21 .20 .23 .21 .20 .22 .21 .19 .22 .21 .19 .19
8 .26 .22 .20 .18 .25 .22 .20 .18 .21 .19 .18 .21 .19 .18 .21 .19 .18 .17
9 .24 .20 .18 .17 .24 .20 .18 .17 .20 .18 .16 .20 .18 .16 .19 .18 .16 .16

10 .23 .19 .17 .15 .22 .19 .17 .15 .18 .16 .15 .18 .16 .15 .18 .16 .15 .14

Determined in Accordance With Current IES Published Procedures  

Luminaire Input Watts = 23.0

Tested According to IES Procedures. Test Distance Exceeds Five  

Times the Greatest Luminous Opening of Luminaire.