Lightolier is a Philips group brand
Job Information
Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • B1108
Architectural Decorative Vetro Downlight
D01
Page 3 of 3
Compact Fluorescent
200
400
0°
30°
60°
90°
100
300
8091CL-D6AO1
Calculite 6" Vetro Downlight, Cat.# 8091CL/D6A01 Opal Lens
32W Sylvania Dulux T/E Triple Tube. Lumen Rating = 2400 LMS.
Universal Ballast #C2642UNVBES(#1)
Candlepower Summary
Angle Along
22.5
45
67.5
Across
LMS
0
460
460
460
460
460
5
447
447
448
449
448
43
10
425
425
426
428
428
15
393
394
396
398
398
112
20
356
357
360
363
364
25
316
317
320
325
327
148
30
274
275
278
284
288
35
231
232
237
245
251
150
40
188
189
194
204
207
45
148
149
152
158
160
119
50
111
111
111
112
113
55
50
50
51
53
54
58
60
42
42
43
44
44
65
36
37
37
37
38
37
70
32
32
32
33
33
75
28
28
28
28
28
30
80
25
25
25
25
25
85
23
23
23
23
23
25
90
20
20
20
21
20
Zonal Lumens and Percentages
Zone
Lumens
% Lamp
%Luminaire
0-30
302
12.61
41.97
0-40
452
18.84
62.73
0-60
629
26.21
87.25
0-90
721
30.04
100.00
40-90
268
11.20
37.27
60-90
91
3.83
12.75
90-180
0
.00
.00
0-180
721
30.04
100.00
** Efficiency = 30.0% **
Certified test report no. 3517FR
Computed by LSI program **TEST-LITE**
SC = 1.0
Prepared For:
Lightolier
Fall River, MA
Coefficients of Utilization
Ceiling
80%
70%
50%
30%
10%
Wall
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Ro
om C
av
ity R
at
io
0 .36 .36 .36 .36 .35 .35 .35 .35 .33 .33 .33 .32 .32 .32 .31 .31 .31 .30
1 .33 .32 .31 .30 .33 .32 .31 .30 .30 .29 .29 .29 .28 .28 .28 .28 .27 .26
2 .31 .29 .28 .26 .30 .29 .27 .26 .28 .26 .25 .27 .26 .25 .26 .25 .24 .24
3 .29 .27 .25 .23 .28 .26 .24 .23 .25 .24 .23 .25 .23 .22 .24 .23 .22 .21
4 .27 .25 .22 .21 .27 .24 .22 .21 .23 .22 .20 .23 .21 .20 .22 .21 .20 .19
5 .26 .23 .20 .19 .25 .22 .20 .19 .22 .20 .18 .21 .20 .18 .21 .19 .18 .18
6 .24 .21 .19 .17 .23 .20 .18 .17 .20 .18 .17 .20 .18 .17 .19 .18 .17 .16
7 .22 .19 .17 .15 .22 .19 .17 .15 .18 .16 .15 .18 .16 .15 .18 .16 .15 .14
8 .21 .18 .15 .14 .21 .17 .15 .14 .17 .15 .14 .17 .15 .14 .16 .15 .14 .13
9 .20 .16 .14 .13 .19 .16 .14 .13 .16 .14 .13 .15 .14 .12 .15 .14 .12 .12
10 .18 .15 .13 .11 .18 .15 .13 .11 .15 .13 .11 .14 .13 .11 .14 .12 .11 .11
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 38.0
Tested According to IES Procedures. Test Distance Exceeds Five
Times the Greatest Luminous Opening of Luminaire.
150
300
0°
30°
60°
90°
75
225
8011CL-D4AO1
Calculite 4” Vetro Downlight, Cat.# 8011Cl D4A01
18W G.E. Biax T/E triple Tube. Lumen Rating = 1200 LMS.
Universal Ballast #C218UNVBES
Candlepower summary
Angle
Mean CP
Lumens
0
244
5
239
23
10
254
15
263
73
20
255
25
233
107
30
204
35
174
107
40
131
45
56
51
50
21
55
17
16
60
15
65
13
13
70
12
75
10
11
80
9
85
9
10
90
8
SC(Along) = 1.3, SC(Across) = 1.5
Certified test report no. 3557FR
Computed by LSI program **TEST-LITE**
SC = 1.2
Prepared For:
Lightolier
Fall River, MA
Zonal Lumens and Percentages
Zone
Lumens
% Lamp
%Luminaire
0-30
203
16.97
49.50
0-40
311
25.92
75.59
0-60
377
31.49
91.85
0-90
411
34.29
100.00
40-90
100
8.37
24.41
60-90
33
2.79
8.15
90-180
0
.00
.00
0-180
411
34.29
100.00
** Efficiency = 34.3% **
Coefficients of Utilization
Ceiling
80%
70%
50%
30%
10%
Wall
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
Ro
om C
av
ity R
at
io
0 .41 .41 .41 .41 .40 .40 .40 .40 .38 .38 .38 .36 .36 .36 .35 .35 .35 .34
1 .39 .37 .36 .35 .38 .37 .36 .35 .35 .34 .34 .34 .33 .33 .33 .32 .32 .31
2 .36 .34 .33 .32 .36 .34 .32 .31 .33 .32 .30 .32 .31 .30 .31 .30 .29 .29
3 .34 .32 .30 .28 .34 .31 .30 .28 .30 .29 .28 .30 .28 .27 .29 .28 .27 .26
4 .32 .30 .27 .26 .32 .29 .27 .26 .28 .27 .25 .28 .26 .25 .27 .26 .25 .24
5 .31 .27 .25 .24 .30 .27 .25 .23 .26 .25 .23 .26 .24 .23 .25 .24 .23 .22
6 .29 .26 .23 .22 .28 .25 .23 .22 .25 .23 .21 .24 .23 .21 .24 .22 .21 .21
7 .27 .24 .21 .20 .27 .23 .21 .20 .23 .21 .20 .22 .21 .19 .22 .21 .19 .19
8 .26 .22 .20 .18 .25 .22 .20 .18 .21 .19 .18 .21 .19 .18 .21 .19 .18 .17
9 .24 .20 .18 .17 .24 .20 .18 .17 .20 .18 .16 .20 .18 .16 .19 .18 .16 .16
10 .23 .19 .17 .15 .22 .19 .17 .15 .18 .16 .15 .18 .16 .15 .18 .16 .15 .14
Determined in Accordance With Current IES Published Procedures
Luminaire Input Watts = 23.0
Tested According to IES Procedures. Test Distance Exceeds Five
Times the Greatest Luminous Opening of Luminaire.