background image

Cleanguard Class 1,000/10,000 Clean Room

CXSW SERIES

Page 2 of 2

Recessed Fluorescent, 2x2, for 15/16" to 1-1/2" wide face T-bar

2 or 3 Lamp

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
Copyright 2004 Lightolier

Section 6/Folio N40-14

Job Information

Type:

Photometry

Model No. CXS2WFAVI26U120SO

coefficients of utilization — zonal cavity method 

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

69

66

63

62

60

58

59

58

56

2

63

58

54

54

51

48

52

50

47

3

57

51

46

48

44

41

46

43

40

4

53

45

40

43

38

35

41

38

34

5

48

41

35

38

34

30

37

33

30

6

45

37

31

35

30

27

34

30

26

7

42

33

28

32

27

24

31

27

23

8

39

30

25

29

24

21

28

24

21

9

36

28

23

27

22

19

26

22

19

10

34

26

21

25

20

17

24

20

17

room cavity ratio

Ordering Information

Explanation of Catalog Number. Example: CXS2WFAVI26U120SOGLR

Options & Accessories

Fusing:

Internal fast-blow fusing. Suffix: 

GLR

.

Internal slow-blow fusing. Suffix: 

GMF

.

Electrical/Wiring Options: 

Consult factory.

Specifications

Materials: Chassis parts

are die-formed code gauge cold rolled steel. Housing

with side rails hemmed over and housing ends turned-in for safe handling.

Finish: Chassis exterior

–black baked polyester enamel. 

Cavity

–white baked

polyester enamel minimum 86% reflectance. Phosphate undercoating.

Lenses:

VI (standard extruded virgin acrylic, 3/16" square based female cones,

running 45° to the panel edge, .125" nominal thickness (pattern 12) installed
smooth side down.

Electrical: 

Thermally protected class “P” ballast C.B.M. approved, non PCB. If

K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: 

I.B.E.W./UL and ULc listed.

CX

Cleanguard

Clean Room:

Class 1,000,

10,000 or

100,000

Clean Room

FA

Lens Frame:

FA 

= Flat

aluminum
frame

W

Ceiling Type:

= Grid 15/16"

to 1-1/2" face
(lay in T-bar)

2

Fixture

Width

Voltage:

120 or 277

Ballast Type:

<

20THD

<

10THD

1-1 & 1-2 Lamp Elec. T8

SO*

H

I

*

1-3 Lamp Elec. T8 

O3*

H3*

1-1 & 1-2 Lamp Elec. TT5 

SB*

I

B*

(40 Watt)

1-3 Lamp Elec. TT5 

X3*

I

3*

LOL T8 Dimming 

PS

*

LOL TT5 Dimming 

PB

*

*Instant Start Standard
Other dimming options, consult factory.

Options:

Add appropriate

suffix to catalog

no, ie: (GLR)

LER = FP - 56.0

IW - 53.7

BF - 0.87

Comparative yearly lighting energy cost per 1000 lumens = $4.24

G02023

DATE: 02-04-02

CXS2WFAVI26U120SO
2 TS  U6,  EACH RATED  2750  LUMENS
FIXTURE WITH FS FRAME AND INVERTED LENS

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.

S

Static

VI

Lens Shielding

Type:

VI (virgin acrylic) .125

standard. For options

consult factory.

Smooth side of

lens towards room.

Lamp Quantity:

2

= 2 Lamp

3

= 3 Lamp

Lamp

Fixture Length:

2U

= T8, 1-5/8" U Lamp

17

= T8, 2' Lamp

6U

= 6" U Lamp (T8)

(2 Lamp Only)

FT

= Twin Tube (T5)

(Nominal 24")

Отзывы: