background image

CXS SERIES 

2x2

CLEANGUARD CLASS 10,000 CLEAN ROOM

RECESSED FLUORESCENT

PHOTOMETRY

MODEL NO. CXS2GFSVI26U120SO

coefficients of utilization — zonal cavity method  

(effective floor cavity reflectance 0.20)

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

69

66

63

62

60

58

59

58

56

2

63

58

54

54

51

48

52

50

47

3

57

51

46

48

44

41

46

43

40

4

53

45

40

43

38

35

41

38

34

5

48

41

35

38

34

30

37

33

30

6

45

37

31

35

30

27

34

30

26

7

42

33

28

32

27

24

31

27

23

8

39

30

25

29

24

21

28

24

21

9

36

28

23

27

22

19

26

22

19

10

34

26

21

25

20

17

24

20

17

room cavity ratio

ORDERING INFORMATION

Explanation of Catalog Number.   Example: CXS2GFSVI26U120SOGLR

CLEANGUARD

WET

LOCATION

Class 10,000

or

100,000

Clean Room

STATIC

FIXTURE

WIDTH

CEILING TYPE:

G

= Grid (lay-in T bar)

F

=Flanged (overlap) Z spline 

and plaster frame

LENS FRAME:

FS

= Flat steel frame

RA

=Regressed 

aluminum frame

FA

=Flat aluminum

frame

LENS/SHIELDING TYPE:

VI=(virgin acrylic) .125

standard. For options

consult factory.
Smooth side of

lens towards room.

LAMP

QUANTITY:

2

=2 Lamp

3

=3 Lamp

LAMP/

FIXTURE LENGTH:

2U

=T8, 1-5/8" U Lamp

17

=T8, 2' Lamp

6U

=6" U Lamp (T8)

FT

=Twin Tube T5

(Nominal 24")

VOLTAGE:

120 or 277

BALLAST TYPE:

<

20THD

<

10THD

1-1 & 1-2 Lamp Elec. T8

SO*

H

I

*

1-3 Lamp Elec. T8

O3*

H3*

1-1 & 1-2 Lamp Elec. TT5

SB*

I

B*

(40 Watt)

1-3 Lamp Elec. TT5

X3*

I

3*

LOL T8 Dimming

PS

*

-

LOL TT5 Dimming

PB

*

-

*

Instant Start Standard

OPTIONS:

Add appropriate suffix

to catalog no., ie: (GLR)

SPECIFICATIONS:

MATERIALS

Chassis parts

are die-formed code gauge cold rolled steel.

Housing with side rails hemmed over and housing ends turned-in for safe
handling.

FINISH

Chassis exterior

–black baked polyester enamel. 

Cavity

–white

baked polyester enamel minimum 86% reflectance. Phosphate undercoating.

LENSES

: VI (standard) extruded virgin acrylic, 3/16" square based female

cones, running 45° to the panel edge, .125" nominal thickness (similar to
pattern 12).

ELECTRICAL

: Thermally protected class “P” ballast C.B.M. approved, non

PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS

: I.B.E.W./UL and ULc Listed.

We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

OPTIONS/ACCESSORIES
PLASTER FRAME

: Catalog Number 

PF24

.

CONTINUOUS ROW INSTALLATION

: For F

type fixtures, half width flanges are required
between fixtures. Order Catalog Number:

S2FCTRIM

(each joint).

FUSING

: Internal fast-blow fusing.

SUFFIX: 

GLR

.

Internal slow-blow fusing.
SUFFIX: 

GMF

.

ELECTRICAL/WIRING OPTIONS

:

Consult factory.

PRINTED IN USA  3/02

A Genlyte Thomas Company

Other dimming options. Consult factory.

TECHNICAL INFORMATION  •  (978) 657-7600
631 AIRPORT ROAD, FALL RIVER, MA 02720  •  (508) 679-8131
C.F.I. DIVISION OF CANLYTE, INC.
525 EDUCATION ROAD, CORNWALL, ONTARIO
CANADA K6H 6C7  •  (613) 938-6221

LER = FL - 56.0

IW - 53.7

BF - 0.87

Comparative yearly lighting energy cost per 1000 lumens = $4.24

CXS2GFSVI26U120SO

CX

S

2

VI

Отзывы: