background image

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 a Philips Group

Section 5/Folio M15-94

Job Information  

Type:

Lightolier is a Philips group brand

Coffaire Drop Basket Surface 

CDB2SPF217 or 317

Page 2 of 2 

Direct/Indirect Surface Mounted Fluorescent – 2' x 2' with Perforated Basket

Static, 1, 2 or 3 Lamp T8

Ordering Information

Explanation of Catalog Number. Example: CDB2SPF217UNVHI

Options/Accessories

Fusing:

Internal fast blow fusing: SUFFIX: 

A

.

Internal slow blow fusing: SUFFIX: 

C

.

Electrical Wiring Options:

Emergency Packs are only avalable for remote mounting.

Consult factory.

For motion or light sensor:

See Folio OA20-10.

Specifications

Performance:

In an installation of 2 lamp 17W luminaires in a room cavity

ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .60. To reduce glare the average brightness at 65° shall not exceed
1634 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 76%. 

Materials: Chassis parts

are die-formed code gauge steel.

Lamp Shield:

22 gauge steel perforated mesh lamp shield with white acrylic

overlay.

Specifications (continued)

Finish: Chassis exterior

– Soft white post painted polyester powder. 

Cavity

– Soft white post

painted polyester powder. Rust preventative undercoating. 

Reflector

– Soft white post painted

polyester powder.el.

Electrical:

Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of

ballast, use wire suitable for at least 90°.

Labels:

I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See:
www.lamprecycle.org

CD

Options:

Add appropriate
suffix to catalog

no., ie: (A)

Coffaire Drop

Basket

Direct/Indirect

Recessed

B

Body Style:

= Surface

Mounted

2

Fixture

Width

S

Ceiling Type:

Surface

P

Perforated

Lamp

Shield

17

Lamp:

(By Others)

17 

=T8 17W

(Nominal 24")

F

Flat White

Reflector

Lamp

Quantity

1

=1 Lamp

2

=2 Lamp

3

=3 Lamp

Voltage:

120, 277 or

UNV

=120-277

Ballast Type:

<

20THD

<

10THD

1 or 2 Lamp Elec. T8

SO*

H

I

*

1-3 Lamp Elec. T8

O3*

H3*

LOL Dimming T8

PS

*

*Instant Start Standard
Other dimming options. Consult factory.

NOTE: 

For 

T8 UNV

, you must use 

H

I

OR 

H3

Ballast Code.

0.0

45.0

90.0

FLUX

0

506

506

506

5

503

504

504

48

15

478

484

491

137

25

431

448

467

207

35

368

400

432

251

45

294

344

390

265

55

210

285

343

251

65

130

227

292

217

75

69

169

231

168

85

18

91

135

89

90

2

31

59

Model No. CDB2SPF217UNVHI

LER = FP - 46.6      IW - 30.8      BF - 0.88
Comparative yearly lighting energy cost per

1000 lumens = $5.15

Report Number: G2007131A
Catalog Number: CDB2SPF217UNVHI
Lamps: (2) F17T8
Luminaire: Coffaire Drop Basket
Ballast: QTP2X17T8/UNV ISN SC
Report is based on 1375 Lumens per lamp.

Efficiency: 69.4%

CIE Type-Direct-Indirect
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.3

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

23.040

23.040

CANDELA DISTRIBUTION

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

1054.

1280.

1451.

55

924.

1254.

1510.

65

727.

1270.

1634.

75

553.

1353.

1850.

85

268.

1354.

2009.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

0

1 62 60 57 56 54 52 54 52 50

0

2 57 52 47 48 45 42 46 43 41

0

3 52 45 40 42 38 34 40 37 34

0

4 47 40 34 37 33 29 36 32 29

0

5 43 35 30 33 28 25 32 28 25

0

6 40 32 26 30 25 22 29 25 21

0

7 37 29 23 27 23 19 26 22 19

0

8 34 26 21 25 20 17 24 20 17

0

9 32 24 19 23 18 15 22 18 15

10 30 22 17 21 17 14 21 17 14

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

392

14.2

24.0

0

0-

0

40

642

23.4

39.3

0

0-

0

60

1158

42.1

70.9

0

0-

0

90

1633

59.4

100.0

90-180

000

0

0.0

00

0.0

0

0-180

1633

59.4

100.0

ZONAL LUMEN SUMMARY

0.0

45.0

90.0

FLUX

0

731

731

731

5

726

727

729

69

15

688

698

708

197

25

621

644

669

297

35

530

573

616

359

45

419

489

552

376

55

298

400

479

353

65

180

313

399

299

75

93

226

307

224

85

23

117

174

116

90

3

40

75

Model No. CDB2SPF317UNVH3

LER = FP - 42.6      IW - 43.9      BF - 0.88
Comparative yearly lighting energy cost per

1000 lumens = $5.63

Report Number: G2007133A
Catalog Number: CDB2SPF317UNVH3
Lamps: (3) F17T8
Luminaire: Coffaire Drop Basket
Ballast: QTP3X17T8/UNV ISN SC
Report is based on 1375 Lumens per lamp.

Efficiency: 55.5%

CIE Type-Direct-Indirect
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.3

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

23.040

23.040

CANDELA DISTRIBUTION

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

1559.

1820.

2054.

55

1312.

1761.

2108.

65

1007.

1751.

2232.

75

745.

1810.

2459.

85

342.

1741.

2590.

LUMINANCE DATA IN CANDELA/SQ. METER

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

564

13.7

24.6

0

0-

0

40

922

22.4

40.3

0

0-

0

60

1651

40.0

72.1

0

0-

0

90

2290

55.5

100.0

90-180

000

0

0.0

00

0.0

0

0-180

2290

55.5

100.0

ZONAL LUMEN SUMMARY

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

0

1 59 56 53 53 50 49 50 49 47

0

2 54 48 44 45 42 39 43 41 38

0

3 49 42 37 40 36 32 38 35 32

0

4 44 37 32 35 31 27 34 30 27

0

5 41 33 28 31 27 24 30 26 23

0

6 38 30 25 28 24 21 27 23 20

0

7 35 27 22 26 21 18 25 21 18

0

8 32 25 20 23 19 16 23 19 16

0

9 30 23 18 22 17 15 21 17 15

10 28 21 16 20 16 13 19 16 13

Отзывы: