Wiring:

After mounting the power/data supply, you are ready to connect power, lumi-
naires, and data to CCLPS602P.

Connecting Luminaires to CCLPS602P 

•  Plug the leader cable connector into a power output receptacle on the front 

of CCLPS602P. Power outputs are labeled Out 1 and Out 2. (See Fig. 2.)

Note: 

When using one luminaire run per CCLPS602P, use Output 1.

OUT 

1

OUT 

2

ENET IN

DMX IN

DMX OUT

To Luminaires

Fig. 2

•  Refer to the user guide for your luminaires to determine maximum number of 

luminaires per power/data supply and specific wiring requirements.

Connecting DMX Data:

CCLPS602P receives DMX data from, and can be controlled by, Lightolier’s full 
line of DMX512 controllers or any third party DMX512 controller.

•  Plug the data RJ-45 connector from the controller into the DMX IN port.
•  To daisy-chain DMX data to another CCLPS602P, connect a CAT5 cable with 

RJ-45 connectors between the DMX OUT port of the first unit and the DMX 
IN port of the next unit. Plug a terminator into the DMX OUT port of the last 
power supply in a data chain. (See Fig. 3.)

OUT 

1

OUT 

2

ENET IN

DMX IN

DMX OUT

To Luminaires

To Luminaires

OUT 

1

OUT 

2

ENET IN

DMX IN

DMX OUT

DMX IN

DMX OUT

DMX IN

Terminator

Lightolier

® 

DMX or 

Color Rotary Dial Controller

Fig. 3

Connecting Power:

•  Connect the IEC power cable to the back of unit. Plug the IEC power cable 

into a standard 100-240VAC outlet. Tighten the screw to secure the clamp. 
(See Fig. 5.)

Note: 

If power supply does not power up (front display is blank) make certain 

power cable is firmly inserted into the receptacle on the back of the unit.

Tighten Screw

To Lock

Fig. 5

Содержание CCLPS602P

Страница 1: ...C and relevant local codes Warning Do not attempt to install or use CCLPS602P until you read and under stand the installation instructions and safety labels Warning Do not use CCLPS602P if power cables are damaged Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules This equipment generates uses and can radiate...

Страница 2: ...ring requirements Connecting DMX Data CCLPS602P receives DMX data from and can be controlled by Lightolier s full line of DMX512 controllers or any third party DMX512 controller Plug the data RJ 45 connector from the controller into the DMX IN port To daisy chain DMX data to another CCLPS602P connect a CAT5 cable with RJ 45 connectors between the DMX OUT port of the first unit and the DMX IN port ...

Страница 3: ...tiple luminaires to the same address The number of lumi naires per group is limited to the maximum number of luminaires connected to Output 1 For example if you have 10 luminaires connected to Output 1 and 12 luminaires connected to Output 2 the maximum group number is 10 To set grouping of luminaire addresses 1 Press and hold the UP and DOWN buttons simultaneously to enter configura tion mode CFG...

Страница 4: ...ta Input Interface Lightolier Lytemode DMX color rotary dial or DMX 512 compatible controllers Data Output Interface 24V Classification Class 2 Listings UL cUL CE PSE Max of Luminaires 12 20 6 36 OUT 1 OUT 2 ENET IN DMX IN DMX OUT CCLPS602P Center Feed Installation Base Address 1 9 2 10 1 2 9 1 20 2 9 1 0 2 9 1 20 Group Address Set to 1 Group Address Set to 1 Example 1 When using a Rainbow Wash wi...

Отзывы: