Lightolier Calculite T7032 Скачать руководство пользователя страница 2

UNITS 5
FEET
FROM
WALL

Units 3 Feet

From Wall

Distance From Ceiling (FT

.)

1

19

20

19

17

17

17

16

15

16

15

13

15

14

11

14

13

9

13

2

26

27

26

23

24

23

21

19

21

19

17

19

18

15

18

17

12

17

3

29

30

29

26

26

26

23

22

23

21

18

21

20

16

20

19

14

19

4

32

32

32

28

29

28

25

26

25

22

22

22

20

20

20

19

17

19

5

33

36

33

30

31

30

27

25

27

25

21

25

23

18

23

23

15

23

6

34

35

34

30

30

30

27

27

27

24

23

24

23

20

23

22

17

22

7

33

35

33

29

30

29

26

27

26

23

22

23

22

20

22

21

17

21

8

32

35

32

28

29

28

25

26

25 22

22

22

20

20

20

19

17

19

9

29

32

29

25

27

25

22

25

22

19

22

19

17

19

17

16

17

16

10

27

30

27

23

26

23

20

23

20

18

20

18

16

18

16

15

17

15

11

24

26

24

21

24

21

19

20

19

17

18

17

15

17

15

13

15

13

12

21

24

21

19

21

19

17

17

17

15

16

15

13

15

13

10

14

10

13

19

22

19

17

19

17

16

16

16

14

14

14

12

14

12

9

13

9

14

17

20

17

15

15

15

14

13

14

13

12

13

10

12

10

8

11

8

Distance From Ceiling (FT

.)

1

44

41

44

37

29

37

34

24

34

33

18

33

2

59

62

59

49

40

49

43

32

43

41

24

41

3

67

74

67

57

50

57

50

35

50

47

26

47

4

72

72

72

58

53

58

50

40

50

46

32

46

5

67

73

67

53

53

53

44

44

44

40

34

40

6

60

62

60

47

50

47

38

42

38

33

35

33

7

51

62

51

41

42

41

32

38

32

27

31

27

8

41

51

41

34

35

34

27

32

27

23

27

23

9

36

45

36

31

31

31

24

28

24

21

23

21

10

32

36

32

27

29

27

23

25

23

20

21

20

11

28

32

28

25

26

25

21

23

21

19

19

19

12

26

29

26

22

24

22

19

21

19

18

18

18

13

23

26

23

22

23

22

18

20

18

17

16

17

14

21

25

21

20

21

20

16

20

16

15

15

15

Coefficients of Utilization

Effective Ceiling Cavity Reflectance

80

70

50

30

10

0

ROOM CA

VITY RA

TIO

50 30

10

50

30

10

50

30

10

50

30

10

50

30

10

0

.81 .80 .78 .80

.78 .77 .77

.75 .74 .74

.72 .72

.71

.70

.70 .68

.76 .73 .71 .75

.72 .70 .72

.70 .69 .70

.69 .67

.68

.67

.67 .65

.71 .67 .66 .70

.67 .66 .68

.67 .66 .67

.65 .64

.67

.64

.62 .61

.67 .64 .62 .67

.63 .61 .65

.63 .60 .64

.62 .60

.63

.60

.59 .56

.64 .59 .57 .63

.59 .56 .62

.59 .53 .60

.58 .56

.59

.57

.55 .54

.60 .56 .53 .59

.56 .53 .59

.56 .52 .57

.55 .52

.57

.54

.52 .51

.56 .52 .49 .56

.52 .49 .55

.51 .49 .54

.51 .48

.53

.50

.48 .48

.53 .49 .47 .52

.48 .47 .52

.48 .47 .51

.48 .46

.50

.48

.46 .45

.49 .46 .43 .49

.46 .43 .48

.45 .42 .48

.45 .42

.47

.44

.42 .41

.47 .43 .39 .46

.42 .39 .46

.42 .39 .45

.42 .39

.45

.42

.39 .38

1
2
3
4
5
6
7
8
9

10

% Wall Reflectance

20% Floor Cavity Reflectance
Conversion Factor: 

200W A-23 (Clear) and 150W A-21 (Clear): F.C. x 1.0; 

300W PS-25, 200W A-23 and 150W A-21 (Gold): F.C. x 0.9

Distance From Ceiling (FT

.)

1

26

28

26

23

23

23

21

19

21

20

15

20

19

13

19

2

36

38

36

31

32

31

27

24

27

25

20

25

24

18

24

3

43

41

43

37

35

37

33

26

33

31

22

31

30

20

30

4

46

47

46

40

41

40

36

29

36

34

23

34

32

21

32

5

50

47

50

41

41

41

37

32

37

34

26

34

32

25

32

6

49

48

49

42

41

42

37

34

37

34

27

34

32

25

34

7

45

46

45

37

40

37

32

33

32

28

29

28

26

26

26

8

40

41

40

34

36

34

28

31

28

25

27

25

22

25

22

9

37

35

37

29

32

29

24

28

24

21

25

21

18

24

18

10

32

34

32

27

29

27

22

26

22

19

22

19

17

21

17

11

29

31

29

25

25

25

21

22

21

18

20

18

16

16

16

12

26

28

26

22

23

22

19

21

19

16

18

16

15

16

15

13

24

25

24

20

22

20

17

19

17

16

16

16

14

15

14

14

22

22

22

18

19

18

16

17

16

15

14

15

14

13

14

UNITS 4
FEET
FROM
WALL

DOUBLE 

WALLWASHER

WA

L

L

WA

L

L

WALL

WASHER

INSIDE CORNER 

WALLWASHER

WA

L

L

WA

L

L

WALL

6'

6'

3'

3

'

47 f.c.

26 f.c.

WALL WASH SIDE

DOWNLIGHT SIDE

Candlepower
Distribution

Downlight Spacing 
Ratio = 1.3

For even wall washing
use a maximum of 2 to 1
spacing (distance
between fixture ÷ dis-
tance to wall).

3'

4'

5'

6'

4'

5'

6'

7'

8'

Footcandles on wall from multiple
units 

Clear cone, 300W PS-25

EXAMPLE: With multiple clear cone
units, using 300W PS-25 lamps, located
3' from wall and 6' on center, (matching
downlights 6' on center), the illumination
on the wall 3' down from the ceiling is
47 f.c. beneath fixtures and 26 f.c.
between fixtures.

5'

6'

7'

8'

9'

10'

Footcandle values are averaged and rounded off and tables are based on a minimum of five units. Conversion Factors: 300W PS-25 units with gold cone,
F.C. x 0.90. 200W A-23 units: clear cone, F.C. x 0.65; gold cone, F.C. x 0.55. 150W A-21 units: clear cone, F.C. x 0.45; gold cone, F.C. x 0.40.

Calculite

®

Incandescent Open Wall Washer

T7032

7 3/8” Aperture A21 / A23 / PS25

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902

Job Information