(FC) is initial footcandles at center of beam.
Beam length (L) and beam width (W) are to
where the candlepower is reduced to 50% of
the center beam candlepower.
CBCP is center beam candlepower.
(C) is distance to the center of the beam.
Lamp data shown is typical, and is based
on bare lamp photometrics. Contact
lamp manufacturers for availability and
performance.
10’ 250 1.7’ 1.7’
15’ 111 2.6’ 2.6’
20’ 63 3.5’ 3.5’
25’ 40 4.4’ 4.4’
8’ 4.6’ 254 1.9’ 1.6’
12’ 6.9’ 113 2.8’ 2.4’
16’ 9.2’ 63 3.7’ 3.2’
20’ 11.5’ 41 4.7’ 4.0’
4’ 6.9’ 195 2.9’ 1.4’
6’ 10.4’ 87 4.3’ 2.1’
8’ 13.9’ 49 5.7’ 2.8’
10’ 17.3’ 31 7.2’ 3.5’
25000 2000
75W AR111
SP
10°
3’ 144 3.5’ 3.5’
5’ 52 5.8’ 5.8’
7’ 27 8.1’ 8.1’
9’ 16 10.4’ 10.4’
3’ 1.7’ 94 5.2’ 4.0’
5’ 2.9’ 34 8.7’ 6.7’
7’ 4.0’ 17 12.1’ 9.3’
9’ 5.2’ 10 15.6’ 12.0’
1’ 1.7’ 163 * 2.3’
2’ 3.5’ 41 * 4.6’
3’ 5.2’ 18 * 6.9’
4’ 6.9’ 10 * 9.2’
1300 2000
75W AR111
WFL
60°
6’ 125 3.2’ 3.2’
8’ 70 4.3’ 4.3’
10’ 45 5.4’ 5.4’
12’ 31 6.4’ 6.4’
5’ 2.9’ 117 3.7’ 3.1’
7’ 4.0’ 60 5.1’ 4.3’
9’ 5.2’ 36 6.6’ 5.6’
11’ 6.4’ 24 8.1’ 6.8’
2’ 3.5’ 141 5.5’ 2.1’
3’ 5.2’ 63 8.2’ 3.2’
4’ 6.9’ 35 10.9’ 4.3’
5’ 8.7’ 23 13.7’ 5.4’
4500 2000
75W AR111
FL
30°
MR16 Low Voltage Halogen Bi-Pin lamps
D FC L W
D C FC L W
D C FC L W
Lamps
Beam Spread
CBCP Rated
(To 50% CBCP)
Life (Hrs.)
0° Aiming Angle
30° Aiming Angle
30° Aiming Angle
30°
Calculite
®
ProSpec
®
Linear Downlight
PB3A1175
Page 2 of 2
3 Light AR 111 Series B
Job Information
Type:
Lightolier
a Genlyte company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2011 Genlyte Group LLC • D0711