background image

**  EFFICIENCY = 42.7%  **

CERTIFIED TEST REPORT NO. 2460FR DATE:, FEB 19, 2004

SC = .7

COMPUTED BY LSI PROGRAM **TEST-LITE** 

Calculite

®

HID Downlight 

C9E28VN

Page 2 of 2

9" Aperture, ED28 (Enclosed), Metal Halide, Narrow Beam

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4

Job Information

Type:

4,500

2,250

6,750

9,000

6,000

12,000

30°

60°

30°

60°

CEILING

80%

70%

50%

30%

WALL

70 50

30

10

50 10

50

10

50

10

RCR

0

.57 .57 .57 .57

.56 .56

.53 .53

.51 .51

.48

1

.55 .54 .53 .52

.53 .51

.51 .49

.49 .48

.46

2

.53 .51 .49 .48

.50 .47

.48 .46

.47 .45

.44

3

.51 .48 .46 .45

.47 .44

.46 .44

.45 .43

.42

4

.49 .46 .44 .42

.45 .42

.44 .41

.43 .41

.40

5

.47 .43 .41 .39

.43 .39

.42 .39

.41 .38

.37

6

.45 .41 .39 .37

.41 .37

.40 .37

.40 .36

.36

7

.43 .39 .37 .35

.39 .35

.38 .35

.38 .34

.34

8

.41 .37 .35 .33

.37 .33

.36 .33

.36 .32

.32

9

.39 .35 .33 .31

.35 .31

.34 .31

.34 .31

.30

10

.37 .33 .31 .29

.33 .29

.33 .29

.32 .29

.28

LUMINAIRE INPUT WATTS = 205

ANGLE

MEAN CP

LUMENS

0

9482

5

8632

809

10

7160

15

6075

1726

20

5041

25

3948

1829

30

2866

35

1919

1239

40

1185

45

666

530

50

218

55

23

60

60

3

65

1

1

70

0

75

0

0

80

0

85

0

0

90

0

175W ED28,

PHILIPS MH COATED LAMP, LUMEN RATING = 12900 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM

Coefficients of Utilization

LUMINANCE SUMMARY CD. / SQ. M.      

ANGLE       MEAN CD/SQ M        

45

23031

55

988

65

78

75

32

85

0

**  EFFICIENCY = 48.0%  **

CERTIFIED TEST REPORT NO. 2450FR, DATE: FEB 12, 2004

SC = .6 

COMPUTED BY LSI PROGRAM **TEST-LITE** 

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

ZONE LUMENS

% LAMP %LUMINAIRE

0-30

4363

33.82

70.45

0-40

5602

43.43

90.45

0-60

6191

48

99.97

0-90

6193

48.01

100.00

40-90

591

4.58

9.55

60-90

1

0.01

0.03

90-180

0

0

0

0-180

6193

48.01

100.00

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

CEILING

80%

70%

50%

30%

WALL

70 50

30

10

50 10

50

10

50

10

RCR

0

.51 .51 .51 .51

.50 .50

.47 .47

.45 .45

.43

1

.49 .48 .47 .46

.47 .45

.45 .44

.44 .43

.41

2

.47 .45 .44 .43

.44 .42

.43 .41

.42 .40

.39

3

.45 .43 .41 .40

.42 .39

.41 .39

.40 .38

.37

4

.43 .41 .39 .37

.40 .37

.39 .37

.38 .36

.35

5

.41 .39 .36 .35

.38 .35

.37 .34

.37 .34

.33

6

.40 .37 .34 .33

.36 .33

.36 .33

.35 .32

.32

7

.38 .35 .32 .31

.34 .31

.34 .31

.33 .30

.30

8

.36 .33 .31 .29

.32 .29

.32 .29

.32 .29

.28

9

.35 .31 .29 .27

.31 .27

.30 .27

.30 .27

.27

10

.33 .30 .27 .26

.29 .26

.29 .26

.29 .26

.25

LUMINAIRE INPUT WATTS = 290

ANGLE

MEAN CP

LUMENS

0

11750

5

11130

1042

10

9674

15

8222

2335

20

6835

25

5292

2464

30

3878

35

2612

1680

40

1598

45

900

716

50

299

55

23

77

60

0

65

0

0

70

0

75

0

0

80

0

85

0

0

90

0

250W ED28

, PHILIPS MH COATED LAMP, LUMEN RATING = 19475 LMS, UNIVERSAL MAGNETIC BALLAST, CL FINISH TRIM

Coefficients of Utilization

LUMINANCE SUMMARY CD. / SQ. M.      

ANGLE       MEAN CD/SQ M        

45

31142

55

999

65

0

75

0

85

0

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

ZONE LUMENS

% LAMP %LUMINAIRE

0-30

5842

30

70.25

0-40

7522

38.63

90.46

0-60

8315

42.7

100

0-90

8315

42.7

100

40-90

793

4.07

9.54

60-90

0

0

0

90-180

0

0

0

0-180

8315

42.7

100

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%